Zhong Hua Jiang
22AWG
5m-5000m
5
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
59.4Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22 AWG 5-Conductor Double-Shielded Cable is a five-core electrical cable for equipment manufacturers, control-panel assemblers, system integrators and distributors. It combines five twisted tinned stranded copper conductors, individual PVC insulation, an aluminum shielding layer and a tinned-copper shield under a PVC outer jacket. The construction is intended for compatible low-voltage signal, instrumentation and control circuits where electromagnetic interference (EMI) needs to be managed.
The published product specifications include a 300V voltage rating, 80°C (176°F) temperature rating, conductor resistance of 59.4 Ω/km at 20°C and a nominal 6.1 mm jacket diameter with a ±0.15 mm tolerance. The five insulated cores are black, red, yellow, white and green. Cable selection must account for conductor function, circuit current, signal protocol, installation conditions and required approvals.

For buyers who need five separately insulated conductors in a single jacket, this 22/5 shielded cable supports multi-wire sensor connections, control signals, monitoring circuits and low-power equipment interfaces, subject to the electrical design. Color-coded cores simplify assembly drawings, conductor identification and servicing, although their functions must be assigned by the equipment wiring diagram.
Aluminum foil and tinned-copper shielding provide two conductive layers to help reduce interference coupling when the cable is correctly routed and terminated. The tinned stranded copper conductors aid termination and help resist surface oxidation. Actual interference reduction depends on installation design, shielding coverage, connector selection and grounding practice.
This product is relevant to OEM equipment assembly, industrial control-panel production, maintenance projects and electrical-wire distribution. Share the intended equipment, cable length per piece or roll, quantity, country of destination and any required documentation to request a quotation. Custom specifications or packaging should be confirmed with the sales team before purchase.
Request 22/5 Shielded Wire Pricing

| Rated Voltage | 300V | Number of Conductors | 5 twisted conductors |
| Rated Temperature | 80°C / 176°F | Wire Size | 22 AWG |
| Conductor Resistance | 59.4 Ω/km at 20°C | Conductor Material | Tinned stranded copper |
| Insulation Resistance | 10 MΩ/km at 20°C | Foil Orientation | One-side aluminum, aluminum facing outward |
| Dielectric Test | 2000 VAC/min | Insulation Material | PVC (RoHS) |
| Material Structure | PVC + tinned copper + aluminum | Jacket Material | PVC (RoHS) |
| Conductor Colors | Black, red, yellow, white and green | ||
| Jacket Diameter | 6.1 ± 0.15 mm | ||
| Available Length | 5 m to 5,000 m | ||
Technical testing note: Insulation resistance is listed as 10 MΩ/km at 20°C and the dielectric test as 2000 VAC/min. Obtain the test method, duration and unit definitions before adopting these figures as purchase acceptance criteria. Confirm RoHS documentation and any AWM style or UL reference for the exact model.
For accurate selection, confirm the required cable length, conductor assignment, signal type, voltage, current, bend requirement, shielding termination and equipment electrical specifications before ordering. For continuously moving cable-carrier applications, verify whether a dedicated shielded chain cable is required.
Request Cable Datasheet and Quote

| UL AWM Style 2464 Reference: Verify Model Records | Aluminum + Tinned-Copper Double Shielding | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistance |
Tinned stranded copper helps maintain conductivity while improving solderability and corrosion resistance. For 22 AWG control and signal wiring, this conductor structure supports stable electrical performance, compact routing and long service life under normal operating conditions.
| Advantage of Tinned Copper | |||
| Comparison Item | Tinned Copper | Pure Copper | CCACopper-Clad Aluminum |
| Easy to Solder | |||
| Better Conductivity | |||
| Anti-Oxidation | |||
| Anti-Corrosion | |||
| Sturdy and Durable | |||
Tinned copper combines copper conductivity with a surface finish that supports solderability and oxidation resistance.
The conductor icons above are illustrative rather than comparative laboratory test results. Bare copper can also be soldered, and measured conductivity depends on material composition, cross-sectional area, conductor construction and temperature.

The double shielded structure uses aluminum and tinned copper shielding to help achieve a stronger shielding effect than a basic unshielded cable. The shielding layer can help contain electromagnetic fields inside the cable and reduce external interference entering sensitive conductors.
In practical equipment wiring, the cable shield should be terminated according to the controller, VFD, motor or machine manufacturer's grounding and EMC instructions. The shield is used for interference control and should not be treated as a replacement for a required protective-earth conductor.
Discuss Shielding and Cable Requirements
![]() | ![]() |
| Transformer | Electronic Instrument |
![]() | ![]() |
| Electrical Appliance | Motor |
Typical evaluation scenarios include CNC controller I/O wiring, electronic instruments, machine-interface harnesses, sensors, measurement devices and industrial automation panels. For RS-232, RS-485, encoders or other defined interfaces, confirm the required number of pairs, pair twist, characteristic impedance, shielding, conductor resistance and maximum transmission length before specifying this five-core cable.
The product may also be considered for compatible low-power control circuits associated with motors or VFD-equipped equipment. It should not automatically be selected for VFD output power, branch-circuit wiring, protective-earth functions or continuous drag-chain motion. Select a purpose-built cable when installation conditions require those characteristics.
Check Your Application with Our Team
A concise cable specification reduces sourcing errors. Confirm the signal and power functions first, then match the cable construction and supporting documentation to the equipment and destination market.
| Conductor allocation | Map the five cores to functions in the equipment wiring diagram; this is five conductors, not five twisted pairs. |
| Electrical suitability | Review 300V/80°C ratings, 59.4 Ω/km conductor resistance, signal levels, current, voltage drop and circuit protection. |
| Mechanical fit | Allow for 6.1 ± 0.15 mm jacket diameter, connector entry, bend radius and fixed versus continuous-motion installation. |
| EMC installation | Confirm shield termination, route separation and enclosure bonding against equipment instructions. |
| Commercial request | State length per piece or reel, total order quantity, packaging, market requirements and documents to be reviewed. |
Send Your 22/5 Cable Specifications
For similar conductor materials and constructions, 22 AWG uses a smaller conductor cross-section than 20 AWG. It can support more compact routing, while a larger conductor generally provides lower resistance and reduced voltage drop over the same cable length. The choice should follow the circuit’s permissible loss, mechanical constraints and required signal characteristics rather than wire gauge alone.
A 22 AWG five-core cable should also be distinguished from cables made with separately twisted pairs. Systems that specify differential-pair impedance or dedicated pair shielding may require another cable construction, even if the core count is sufficient.
Ask About 22 AWG Shielded Cable Options
Alongside this 22 AWG five-conductor double-shielded cable, Zhong Hua Jiang offers other shielded wire configurations for different conductor counts, wire gauges, equipment connections and cable-motion requirements.

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.
The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.
![]() | ||
| Quality Assurance Product inspection and quality-control procedures before shipment. | Patents and Certifications Long-term CNC manufacturing experience and patented spindle designs. | Additional Brand Value Integrated product support for CNC machines, spindles, accessories and wiring. |
![]() | ||
| Reasonable Price Direct factory communication for specifications, quantities and custom lengths. | Full Time Service Technical support for cable gauge, conductor count and application selection. | Fast and Reliable Delivery Production coordination, shipment updates and export-order service. |
CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.
Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.
The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.
Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.
Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

For purchasing and regulatory review, verify the exact cable model, manufacturer file, product markings and available RoHS documentation. UL AWM Style 2464 is referenced for this cable family, but a style description alone does not establish model-specific UL recognition. Request the supporting certificate or file number and confirm the applicable labeling. End-use suitability also depends on equipment and installation requirements.
Request Model-Specific Documentation

It is used for five-core signal, control and low-voltage equipment wiring where EMI reduction is important. Typical applications include CNC machines, VFD spindle control, stepper motors, automation panels, electronic instruments, sensors, electrical appliances, transformers, 3D printers, RS-232-style control wiring and audio or control signal paths.
“22/5” means the cable contains five insulated 22 AWG conductors. In this product, the five conductors are twisted and protected by aluminum and tinned-copper shielding layers inside an overall PVC jacket.
The listed rated voltage is 300V and the listed rated temperature is 80°C / 176°F. Final suitability depends on circuit design, load, installation environment, applicable standards and machine-manufacturer requirements.
The aluminum foil and tinned-copper shielding layers form conductive barriers around the insulated conductors. When terminated correctly, these layers help reduce interference from motors, VFDs, power supplies and other noise sources, improving signal stability in sensitive equipment wiring.
Shield termination depends on the equipment, frequency range, enclosure bonding and EMC design. Follow the CNC controller, VFD, motor or equipment manufacturer's wiring instructions. The cable shield should not replace a required protective-earth conductor.
Both products use 22 AWG conductors, but 22/5 provides five insulated cores while 22/4 provides four insulated cores. Choose 22/5 when the circuit requires an additional signal, control, feedback or common conductor in the same shielded cable.
It is mainly used for low-voltage control, signal and light-duty circuits. The final current capacity depends on the installation, temperature, cable length, bundling and applicable electrical standards. Verify the circuit current before using 22 AWG cable for power transmission.
Standard flexible shielded cable may be suitable for fixed or occasional-flex installations. Continuous high-cycle motion generally requires a cable specifically designed for drag chains. Provide bend radius, travel distance, speed and cycle frequency so the proper cable type can be confirmed.
Yes. The available length range is 5 m to 5,000 m. Buyers can provide the required roll length, total quantity, packing preference, labeling needs, application and destination market for quotation confirmation.
Provide the cable gauge, conductor count, required length, estimated quantity, voltage, current, equipment model, installation movement, conductor-color requirement, termination method and delivery destination. These details help confirm the right cable and produce an accurate quotation.
For project evaluation, request the applicable product data sheet, available inspection documentation and required compliance records. Confirm the test methods, acceptance limits and supporting records for the exact cable model ordered.
No. This product has five individually insulated conductors in one cable, as described in the published construction. Five twisted pairs would require ten insulated conductors. Check the specific pair arrangement if the interface requires controlled differential transmission.
It may be considered for compatible encoder, limit-switch or sensor circuits when the number of conductors, signal level and installation requirements match. Verify the device maker’s requirements for twisted pairs, impedance, shielding, voltage drop and cable motion before selecting it.
Core count alone does not establish compatibility with RS-485 or RS-232. Confirm whether the protocol requires dedicated twisted pairs, characteristic impedance, maximum run length and shielding arrangements. Use a purpose-specified communication cable where the equipment standard calls for one.
For equivalent materials and construction, 20 AWG has a larger conductor cross-section and typically lower resistance per unit length. Evaluate the voltage drop and signal performance over the required run; the published 22 AWG resistance for this product is 59.4 Ω/km at 20°C.
The listed outside diameter is 6.1 ± 0.15 mm. Compare this tolerance with the gland sealing range, connector strain-relief capacity and enclosure entry specifications before ordering.
Do not assume conductor function from its color alone. The green core is one of five insulated conductors; a protective-earth connection must meet the equipment wiring design and applicable electrical rules. The shielding layer is not a substitute for a required protective-earth conductor.
No cable shield eliminates every source of interference. Results depend on frequency, cable routing, shield continuity, connectors, grounding and nearby power circuits. Keep signal wiring separated from noisy conductors where the system design requires it.
Only when the motor driver’s operating current, conductor temperature, voltage drop and installation requirements are compatible with the cable. This product is mainly presented for control and signal applications; the 300V rating is not a current-carrying-capacity rating.
No. AWM style descriptions define construction and use parameters. Request the exact manufacturer file or recognized component documentation and confirm the model, marking and end-use conditions in the relevant certification records.
The published data lists insulation resistance as 10 MΩ/km at 20°C and dielectric test as 2000 VAC/min. Buyers should ask for the measurement method, duration, sample conditions and unit definitions before using either value as a purchasing acceptance limit.
Request the model-specific data sheet, applicable material compliance declaration, available certification records, conductor and insulation details, and any required inspection or test report. Check applicability to the destination market and finished equipment.
Minimum order quantity and production lead time should be confirmed for the requested product configuration. Provide required length, total quantity, packaging and delivery destination to obtain the current commercial terms.
Quick Links