You are here: Home » Products » Shielded Wire » Double Shielded cable » 22AWG » Zhong Hua Jiang 22AWG 4-Core Double-Shielded Cable

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Zhong Hua Jiang 22AWG 4-Core Double-Shielded Cable

Zhong Hua Jiang 22AWG 4-core double-shielded cable features four tinned stranded copper conductors, aluminum and copper shielding, PVC insulation, a 300V/80°C rating and a 5.2mm jacket.
  • 22AWG 4 Core

  • Zhong Hua Jiang

  • 22AWG

  • 5m-5000m

  • 4

  • Tinned stranded copper

  • PVC(RoHS)

  • 300V

  • 80℃/176℉

  • 59.4Ω/KM20℃

  • 10MΩ/KM20℃

  • 2000AC V/min

Availability:

22 AWG 4 Conductor Double Shielded Wire Overview

22 AWG 4 conductor double shielded electrical wire for CNC and signal wiring

Zhong Hua Jiang 22 AWG 4-Conductor Double-Shielded Cable is a four-core electrical cable for compatible CNC controllers, automation panels, instrumentation and low-voltage control or signal circuits. Four insulated tinned stranded-copper conductors are twisted within an aluminum and tinned-copper double-shielded construction, with PVC insulation and a PVC outer jacket. This configuration is intended for OEM equipment builders, distributors and professional installers requiring four separate conductors and interference protection.

The published ratings include 300V, 80°C (176°F), 59.4 Ω/km conductor resistance at 20°C and a 5.2 ± 0.20 mm cable outer diameter. The four individually insulated conductor colors are black, red, yellow and white. Confirm the signal interface, wiring diagram, mechanical conditions, shield termination and all applicable installation requirements before specifying the cable.

Cross-section layout of 22 AWG 4 core double shielded wire

22 AWG Four-Core Shielded Cable for Industrial Buyers

This 22/4 double-shielded control cable provides four insulated 22 AWG cores in one compact jacket, making it a candidate for suitable control-panel connections, machine auxiliary controls, low-power sensor interfaces and electronic-instrument wiring. Individual conductor colors aid identification during harness assembly and maintenance; actual core functions are defined by the equipment wiring diagram.

The aluminum layer and tinned-copper shielding layer help limit electromagnetic interference when properly terminated. Tinned stranded copper offers good solderability and resistance to surface oxidation. Shielding performance is influenced by connection quality, cable routing, bonding and the electromagnetic environment; double shielding does not guarantee immunity to all interference.

For industrial OEM orders, maintenance projects or wholesale requirements, send the required cut or reel length, quantity, application, connector or gland dimensions and destination market. Discuss any nonstandard labeling, packaging or conductor configuration with Zhong Hua Jiang for availability and quotation confirmation.

Request 22/4 Shielded Wire Pricing

Request 22/4 Shielded Cable Wholesale Pricing

22 AWG 4-Conductor Shielded Cable Specifications

22 AWG 4 conductor double shielded cable product view

22 Gauge 4 Conductor Wire

Rated Voltage 300V Number of Conductors 4 twisted conductors
Rated Temperature 80°C / 176°F Wire Size 22 AWG
Conductor Resistance 59.4 Ω/km at 20°C Conductor Material Tinned stranded copper
Insulation Resistance 10 MΩ/km at 20°C Foil Orientation One-side aluminum, aluminum facing outward
Dielectric Test 2000 VAC/min Insulation Material PVC (RoHS)
Material Structure PVC + tinned copper + aluminum Jacket Material PVC (RoHS)
Conductor Colors Black, red, yellow and white
Jacket Diameter 5.2 ± 0.20 mm
Available Length 5 m to 5,000 m

Engineering note: The supplied table lists insulation resistance as 10 MΩ/km at 20°C and the dielectric test as 2000 VAC/min. Confirm the measurement units, test conditions and acceptance criteria in the manufacturer’s current data sheet. The 300V insulation rating is not a statement of permissible conductor current; assess voltage drop and ampacity for the actual installation.

Request 22 AWG 4-Core Cable Specifications and Quote

For accurate selection, confirm the required cable length, conductor assignment, signal type, voltage, current, bend requirement, shielding termination and equipment electrical specifications before ordering. For continuously moving cable-carrier applications, verify whether a dedicated shielded chain cable is required.

Double-Shielded Cable Design and Benefits

Shielded cable material and construction illustration

AWM Style 2464 Reference — Confirm Exact Cable Documentation Aluminum + Tinned-Copper Double Shielding Tinned Copper Core

Why Choose Our Wire

Shielded cable conductor and insulation structure

Oxidation-resistant tinned copper wire icon Low eccentricity shielded cable icon High conductivity tinned copper cable icon PVC insulation resistance icon
Oxidation Resistance Low Eccentricity High Conductivity Insulation Resistance

High Conductivity

The four conductors are specified as tinned stranded copper with a published resistance of 59.4 Ω/km per conductor at 20°C. Tin plating aids solderability and protects copper surfaces against oxidation. It does not make copper inherently more conductive than bare copper of the same cross-section. For electrical sizing, check conductor resistance, required current, temperature, circuit length and connector suitability.

Advantage of Tinned Copper
Comparison Item Tinned copper conductorTinned Copper Bare pure copper conductorPure Copper Copper clad aluminum conductorCCA
Copper-Clad Aluminum
Easy to Solder Recommended conductor feature Standard conductor feature Standard conductor feature
Copper Conductor Recommended conductor feature Recommended conductor feature Standard conductor feature
Anti-Oxidation Recommended conductor feature Standard conductor feature Standard conductor feature
Anti-Corrosion Recommended conductor feature Standard conductor feature Standard conductor feature
Sturdy and Durable Recommended conductor feature Standard conductor feature Standard conductor feature

The material-comparison images are general illustrations, not product-specific comparative laboratory results. For supplier qualification, use the cable data sheet, measured resistance, conductor identification and relevant test documentation rather than graphical checkmarks alone.

Tinned stranded copper combines copper conductivity with tin-plated surfaces that support soldering and oxidation resistance.

Double Shielded Layer

Shielded cable material and construction illustration

An aluminum layer and a tinned-copper shielding layer enclose the insulated cores to help manage electromagnetic coupling from nearby motor drives, relays and switching devices. The effectiveness of this construction depends on shielding continuity, termination, enclosure bonding, cable placement and noise frequency.

Terminate the shielding according to the CNC controller, VFD, instrumentation or machine manufacturer’s EMC instructions. One-end versus both-end bonding depends on the specific system; do not use the cable shield in place of a required protective-earth conductor. Keep sensitive control wiring appropriately separated from motor power cables whenever practicable.

Discuss Cable Shielding and OEM Requirements

Applications for 22/4 Shielded Control Cable

22 AWG shielded wire for transformer connections 22 AWG shielded wire for electronic instruments
Transformer Electronic Instrument
22 AWG shielded wire for electrical appliances 22 AWG shielded wire for motors and CNC control equipment
Electrical Appliance Motor

This four-conductor cable can be evaluated for suitable CNC controller inputs and outputs, equipment status and auxiliary control circuits, sensor connections, compact electronic instruments, automation panels and low-voltage monitoring systems. Use the approved wiring diagram to assign each conductor. For RS-485, CAN, encoder feedback or other defined communication links, verify whether the system requires individually twisted pairs, controlled impedance, specified capacitance and dedicated shielding construction.

A four-core control cable is not automatically interchangeable with a four-conductor motor-power or VFD output cable. Similarly, conventional flexible shielding does not establish continuous-motion drag-chain suitability. Select the final wiring type according to electrical load, flex cycle, bending radius, ambient conditions and manufacturer approval.

Zhong Hua Jiang shielded electrical wire product range

Check This Cable for Your Equipment

How to Select 22 AWG 4-Conductor Shielded Cable

Choosing the correct cable requires matching the number of insulated cores, electrical characteristics, shielding method and mechanical conditions to the actual equipment circuit. Four conductors can carry four separately assigned connections, but four cores do not necessarily mean two individually twisted differential pairs.

Technical Selection Checklist for OEM and Distributor Orders

Selection Factor 22 AWG 4-Core Configuration / Buyer Check
Conductors Four twisted 22 AWG tinned stranded-copper conductors; black, red, yellow and white identification.
Published electrical ratings 300V; 80°C; 59.4 Ω/km at 20°C. Verify conductor current and circuit voltage drop.
Cable entry and routing 5.2 ± 0.20 mm listed jacket diameter; confirm gland sealing range, bend requirements and installed clearances.
EMI shielding Aluminum and tinned-copper layers; verify continuity, grounding method and cable separation.
Electrical interface Confirm circuit pinout and whether individually twisted signal pairs, characteristic impedance or capacitance limits apply.
Sourcing details Length per cut or reel, order quantity, packaging, destination, labeling and document requirements.

How to Evaluate Voltage Drop in Long Cable Runs

The published 20°C conductor resistance is 59.4 Ω/km, equivalent to 0.0594 Ω/m per conductor. In a two-wire supply-and-return circuit, approximate resistance for the conductors is 2 × one-way run length × 0.0594 Ω/m. Multiply by circuit current to estimate voltage drop at 20°C, before allowing for termination resistance or conductor-temperature effects. Validate the actual conditions and applicable installation rules.

Send Your 22/4 Wiring Requirements

22/4 vs 22/2, 22/5 and 20/4 Shielded Cable

Cable Type Core Count / Relative Gauge Selection Consideration
22 AWG 4-core (this cable) Four insulated 22 AWG conductors For compatible four-connection signal and low-power control circuits.
22 AWG 2-core Two insulated 22 AWG conductors For circuits requiring only two signal or control connections.
22 AWG 5-core Five insulated 22 AWG conductors For a wiring diagram requiring one more insulated conductor.
20 AWG 4-core Four insulated 20 AWG conductors Larger conductor cross-section, generally lower resistance than 22 AWG with comparable construction; verify its model-specific diameter.

The right selection depends on the cable’s internal lay, noise environment, intended communication signal, installation movement and electrical loads. Do not assume that different gauges or core counts are interchangeable simply because the jacket or connector fits.

Compare Four-Core Shielded Cable Configurations

Related Shielded Electrical Cables

Alongside this 22 AWG 4-core double-shielded cable, Zhong Hua Jiang offers other conductor sizes, core counts and shielded cable configurations for compatible machine control and electrical-equipment connections. Confirm the specifications and intended use of each model before selection.

Company Profile

Zhong Hua Jiang CNC spindle motor and electrical wire manufacturer

Electrical Shielded Wire Manufacturer

Zhong Hua Jiang manufacturing company profile

How We Started

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.

What Makes Us Proud

The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.

Why Choose Us

Zhong Hua Jiang quality assurance, patents and brand advantages
Quality Assurance
Product inspection and quality-control procedures before shipment.
Patents and Certifications
Long-term CNC manufacturing experience and patented spindle designs.
Additional Brand Value
Integrated product support for CNC machines, spindles, accessories and wiring.
Zhong Hua Jiang price, service and delivery advantages
Reasonable Price
Direct factory communication for specifications, quantities and custom lengths.
Full Time Service
Technical support for cable gauge, conductor count and application selection.
Fast and Reliable Delivery
Production coordination, shipment updates and export-order service.

Leading CNC Machine / CNC Spindle Motor Manufacturer Since 2000

Our Product Range

CNC Router Machines

CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.

CNC Spindle Motors

Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.

CNC Accessories

The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.

Electrical Wires

Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.

Stepper Motors

Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

Product Documentation and Compliance

General product documentation image; confirm certificate applies to selected cable model

The original literature refers to UL2464-style construction and PVC (RoHS). A wiring-style reference or a general certificate illustration does not establish recognition or compliance for every supplied model. Ask the supplier for product-specific markings, the applicable UL file or certification record where relevant, current material declarations and any test evidence required by the destination market.

Request Model-Specific Cable Documents

Customer Feedback

Customer feedback for Zhong Hua Jiang shielded electrical wire

FAQ

What is 22 AWG 4 conductor double shielded wire used for?

It is intended for compatible four-core signal, control and low-power equipment connections where interference control matters. Examples for evaluation include CNC machine I/O, auxiliary control circuits, electronic instruments, sensor interfaces and automation panels. Confirm the electrical requirements and wiring diagram for each application.

What does 22/4 shielded cable mean?

The designation 22/4 identifies four insulated 22 AWG conductors. This cable lists four twisted conductors and aluminum plus tinned-copper shielding layers under a PVC jacket. It does not by itself confirm two individually twisted pairs.

What are the voltage and temperature ratings?

The listed voltage rating is 300V and the listed temperature rating is 80°C (176°F). The jacket outer diameter is 5.2 ± 0.20 mm and conductor resistance is 59.4 Ω/km at 20°C. The allowable current must be determined for the actual installation.

How does double shielding improve EMI resistance?

The combination of aluminum and tinned-copper shielding can reduce unwanted electromagnetic coupling when correctly installed. Actual effectiveness depends on shield coverage, bonding, terminations, wiring layout and the frequencies of nearby interference sources.

Should the cable shield be grounded at one end or both ends?

There is no universal rule. Bonding at one or both ends depends on the controller, enclosure, grounding arrangement and EMC requirements. Follow the system manufacturer’s documentation. The shield is not a replacement for a protective-earth conductor.

What is the difference between 22/4 and 18/4 shielded wire?

Both describe four insulated conductors, but 18 AWG has a larger conductor cross-section than 22 AWG and generally a lower electrical resistance for comparable copper construction. Select based on current, voltage drop, cable routing and the exact model specifications.

Is 22 AWG shielded wire suitable for power wiring?

It is primarily a small-gauge control and signal cable. Some low-power circuits may be suitable if the equipment design and applicable rules allow them. The 300V insulation rating does not determine ampacity; check current, heating, length, bundling and voltage drop.

Is this cable suitable for drag-chain or continuous-motion use?

The published product details do not establish a continuous-flex cycle rating. For CNC moving axes and high-cycle cable carriers, select a cable with confirmed chain-duty construction, bend radius, travel, speed and service-life suitability.

Can the length and packaging be customized?

The supplied specifications list available lengths from 5 m to 5,000 m. Tell the sales team the required cut or reel length, total order quantity, packing method and label requirements so availability and any customization can be confirmed.

What information should I provide when requesting a quote?

Provide 22 AWG, four cores, required length per piece or reel, total quantity, equipment and signal type, operating voltage, current, bend or motion requirements, connector needs, shipment country and required certification documents.

How does Zhong Hua Jiang control product quality?

Buyers should confirm the applicable production inspection criteria and request the current model-specific data sheet, available quality records and any required test or compliance documentation for the exact order.

Does this 22/4 cable contain two individually twisted pairs?

Not necessarily. The source specifications describe four twisted insulated conductors but do not identify two independent twisted pairs. Ask for the cable lay drawing if your circuit requires a specific pair structure.

Can 22 AWG four-core shielded wire be used for RS-485?

Some RS-485 networks require controlled-impedance twisted-pair cable. This listing does not specify characteristic impedance or independent pair construction; select it only after checking the transceiver and system-cable requirements.

Can it be used for CAN bus or encoder feedback?

Only after confirming the applicable interface specifications, cable pairing, impedance, shielding, cable length and mechanical duty. Four insulated conductors alone do not qualify a cable for CAN or differential encoder signals.

What is the outside diameter of this 22 AWG four-core cable?

The listed overall jacket diameter is 5.2 ± 0.20 mm. Verify the compatible cable gland, strain relief and connector entry range before assembly.

Which colors identify the four insulated conductors?

The listed colors are black, red, yellow and white. Conductor colors aid identification but do not assign electrical functions without the approved equipment wiring diagram.

What is the difference between 22/4 and 22/5 shielded wire?

Both have 22 AWG insulated conductors. The 22/4 configuration has four cores; 22/5 has five. Select the required conductor count according to the number of signals, supplies, returns and common connections in the circuit.

How does 22 AWG compare with 20 AWG for control wiring?

With comparable material and construction, 20 AWG has a larger cross-sectional area and generally lower electrical resistance than 22 AWG. The 22 AWG version may suit more compact low-current wiring, subject to the overall cable and connector requirements.

How can I estimate voltage drop in a long 22 AWG cable?

The published conductor resistance is 59.4 Ω/km at 20°C. For a two-conductor supply-and-return loop, calculate approximate loop resistance from twice the one-way cable length and 0.0594 Ω/m, then multiply by current. Adjust for actual temperature and termination resistance.

Should a shielded control cable run beside a VFD output cable?

Sensitive signal wiring should be routed and separated as recommended by the machine or drive manufacturer. Proper bonding and shielding can help, but long parallel runs next to high-noise motor-power cables may increase interference.

Does the UL2464 reference confirm this exact cable is UL recognized?

No. A reference to AWM Style 2464 alone does not verify that the supplied model has an applicable UL file or recognition. Request the exact product identification, markings and relevant certification evidence.

What do the 10 MΩ/km and 2000 VAC/min entries mean?

Those values appear in the published table as insulation resistance and dielectric test. The original listing does not provide complete test conditions or unit definitions, so request the current manufacturer test method before using them as acceptance criteria.

Is the tinned copper core more conductive than bare copper?

Tin plating improves solderability and helps resist surface oxidation; it does not inherently increase the conductivity of equivalent bare copper. Verify performance using the stated conductor resistance and actual conductor construction.

What are the bulk length and packaging options?

The source lists cable lengths from 5 m to 5,000 m. Reel sizes, cut lengths, export packaging and labeling should be quoted for the specific requested order.

Which documents should an industrial importer request?

Request the model-specific specification, PVC material and RoHS documentation where applicable, any recognized-product certification records and relevant inspection or dielectric-test reports needed in the destination market.

Contact Zhong Hua Jiang for Pricing and Custom Lengths

Previous: 
Next: 

Product Category

Apply Our Best Quotation

Global Recruitment of Authorised Agents!

Join us as an exclusive distributor of CNC Router Machines and CNC Spindle Motors. As a professional manufacturer, we provide high-performance machines, attractive profit margins, technical training, and full marketing support. Build a strong partnership with us and expand your market with confidence.

Products

Quick Links

Contact Us

   zhonghuajiang@huajiang.cn
  +86-13915011877
   No.379-2, Hengyu Road, Henglin town, Wujin District, Changzhou, Jiangsu, China
© COPYRIGHT 2025 CHANGZHOU HUAJIANG ELECTRICAL CO.,LTD ALL RIGHTS RESERVED.