22AWG 4 Core
Zhong Hua Jiang
22AWG
5m-5000m
4
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
40.1Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22AWG 4-conductor shielded drag chain cable is intended for compatible CNC sensor wiring, low-current controls, equipment automation and moving cable-carrier assemblies. Four twisted stranded tinned-copper conductors, PVC insulation and jacket, and an overall shield provide a compact multi-core cable layout for installations where cable movement and electrical noise must be assessed.
The supplied product specification lists a 300V voltage rating, an 80°C (176°F) temperature rating and a 5.7 ± 0.3mm overall cable diameter. This 22/4 cable may suit compatible four-wire control and signal connections when current, voltage drop, cable travel, connector fit and the machine wiring diagram are checked.
Request a 22AWG Four-Core Cable Quote
Four insulated stranded tinned-copper conductors are twisted within a cable with an overall shielding layer. The technical information identifies PVC insulation and outer jacket and lists cotton rope and cotton paper filler. The final wiring assignment must follow the equipment manufacturer’s drawing.
For engineering approval, request a cross-sectional drawing, shielding details, conductor resistance report and dynamic bend-radius data for this specific 22AWG four-core model. Confirm that the cable, connectors and machine design meet the installation environment before making a bulk purchase.

This 22AWG four-core shielded chain cable is intended for CNC equipment manufacturers, automation integrators, professional repair teams, importers and industrial wire distributors who require four insulated conductors for compatible low-current sensor or control systems.
An overall cable shield can help reduce unwanted electromagnetic coupling near motor drives, control cabinets and switching devices when installed and terminated correctly. Effective screening also depends on cable routing and bonding. The shield is not an extra insulated conductor or a substitute for required protective earth.
Send your required 22AWG × 4 configuration, cable length, quantity, equipment application, control voltage and current, bend-radius requirements, termination details and intended delivery destination to discuss a suitable quotation.

| Rated Voltage: | 300V | Number of Conductors: | 4 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 22AWG |
| Conductor Resistance: | 40.1 Ω/km at 20°C (as published; verify test report) | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green, Red | ||
| Jacket Dia(mm): | 5.7 ± 0.3 | ||
The published table lists conductor resistance as 40.1 Ω/km at 20°C. Obtain the measurement report for the exact 22AWG four-core cable before using this value for a voltage-drop or electrical-load calculation.
For insulation resistance, dielectric testing and any UL or RoHS claims, confirm the test units, conditions, standard and document applicability with the supplier for the actual ordered cable part number.
Request Four-Core Cable Technical Data

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The cable is marketed for moving drag-chain installations. Promotional material mentions 15 million bending cycles, but actual mechanical life depends on testing and operating conditions; obtain the relevant test report before using a cycle count as a design limit.
Check the cable manufacturer’s minimum dynamic bend radius, drag-chain travel distance, speed, acceleration, installation clearance and strain relief. No single bend-radius value can be reliably inferred from the outside diameter alone.
The published 5.7 ± 0.3mm outside diameter helps buyers assess space requirements inside cable carriers, glands and control enclosures. Confirm dimensions, strain relief and dynamic movement against the actual cable drawing before purchase.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned stranded copper combines electrical conductivity with practical solder termination and resistance to oxidation at exposed strand surfaces.
Cable service life depends on conductor stranding, jacket construction, bend radius, carrier travel and installation conditions.
Use the verified conductor resistance and total run length to assess voltage drop and signal integrity for the actual circuit.

The cable shield can help reduce unwanted electromagnetic interference from adjacent electrical equipment when correctly installed.
For sensitive control and sensor circuits, check the machine maker’s instructions for shield termination, separation from motor-output cables and electrical bonding.
A cable shield does not replace a dedicated protective-earth conductor. Follow the machine’s approved safety and grounding design.
The original promotional images refer to 15 million bending cycles, but do not identify a specific dynamic bend radius, travel distance, speed, cycle rate or acceptance criterion. A test report and cable-carrier operating parameters are needed for a defensible mechanical-life assessment.
Discuss Drag Chain Cable Requirements

A compact four-core shielded cable option for suitable multi-wire controls routed through dynamic cable carriers.
Potential application areas include compatible four-wire sensors, CNC position or limit controls, low-current machine interface wiring and industrial automation connections.
The four-conductor 22AWG chain cable can provide separate paths for compatible multi-core control and sensor wiring. The construction does not automatically meet the needs of a particular serial data protocol, encoder interface, motor power output or safety circuit. Check the specified electrical requirements and core assignment first.
For an accurate OEM quotation, provide the required run length, order volume, approved wiring diagram, required current and voltage, cable-carrier travel and dynamic bend radius, connector specification, local environment and packaging expectations.
A four-conductor cable contains four insulated conductors plus its stated overall shield. Confirm the equipment pinout, control current, required voltage, cable length, moving versus fixed installation and interference environment. The shield is not a fifth insulated core and is not automatically a protective-earth conductor.
Use the number of individual insulated paths specified by the controller, sensor or machine wiring diagram. Conductor count alone cannot establish compatibility, continuous current, transmission characteristics or the protective-earth arrangement.
| Cable option | Insulated cores | Typical evaluation |
| 22AWG × 2 | 2 | Compatible two-wire switches and sensor signal loops |
| 22AWG × 3 | 3 | Compatible three-wire sensor and control connections |
| 22AWG × 4 | 4 | Compatible four-wire control or multi-signal connections |
The outer diameter is listed as 5.7 ± 0.3mm. Review the cable carrier’s permitted fill, bending radius, travel profile, entry gland and strain relief. Ask for the approved dynamic bend-radius rating rather than deriving it from the diameter alone.
The source describes Black, White, Yellow and Green, and Red. Ask for the actual core color photograph or cable drawing to establish whether Yellow/Green means one striped core, then assign individual conductors according to the electrical drawing. Bond or terminate the shield in accordance with the controller supplier’s EMC instructions.
For sensor supply and control wiring, calculate voltage drop using the actual measured conductor resistance, circuit current and full conductor path length. The published 40.1 Ω/km figure should be confirmed with a product-specific report before engineering sign-off.
Send Your 22AWG Four-Wire Cable Requirements
Explore the shielded drag-chain and double-shielded wire ranges from Zhong Hua Jiang. Compare conductor count, wire gauge, moving versus fixed installation and cable dimensions before selecting an equivalent wiring product.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company offers CNC router machine configurations such as 3018, 3020, 3040 and 6090 for engraving, cutting and related machining work.
The product range includes air-cooled and water-cooled spindle motors for different CNC machine power and cooling requirements.
CNC accessories include limit switches, Z probes, emergency-stop buttons and related machine-control parts.
The electrical wire range includes shielded drag-chain cables for moving applications and other shielded wire constructions for equipment wiring.
Stepper motors are used for controlled positioning in compatible CNC and automation systems.
For pricing or distributor supply inquiries, specify 22AWG × 4, requested cable lengths, order quantity, equipment application, operating voltage and current, number of moving cycles or cable-carrier travel where relevant, termination requirements, packaging preferences and destination.
For technical qualification, request the approved four-core color diagram, current conductor-resistance test data, shielding construction, relevant compliance documents and installation or flex-test conditions. Confirm that certificates relate to the cable being purchased.
Request OEM / Distributor Pricing

Company-level documents and images may show multiple CNC or cable product families. For procurement approval, request applicable records identifying this exact 22AWG four-conductor cable model.

The cable is intended for suitable 22AWG × 4 low-current control or signal connections in CNC machinery, sensor assemblies and cable drag chains where an overall shield can help manage electrical interference.
Shielding helps limit coupled electrical noise near drives, switching devices and power cables when installed correctly. Route and terminate the shield according to the controller and equipment manufacturers’ requirements.
The product is presented for cable-carrier movement. However, minimum dynamic bend radius, working speed, stroke length and flex-test conditions are not stated in the supplied technical table. Request these data for the specific ordered cable.
The supplier table states 22AWG × 4 twisted tinned stranded copper cores, 300V, 80°C, PVC insulation and jacket, and a 5.7 ± 0.3mm cable diameter. The stated 40.1 Ω/km conductor resistance at 20°C is a supplier-published value requiring test-report verification.
The color description states Black, White, Yellow and Green, and Red for four cores. Confirm from the approved cable diagram whether Yellow/Green is a single striped conductor. Do not infer protective-earth assignment from a color phrase alone; follow the wiring diagram and applicable safety requirements.
Tinned stranded copper provides conductivity, solderability and useful resistance to oxidation at exposed surfaces. Individual strands contribute to flexibility in an appropriately designed moving-cable assembly.
Discuss cable length, conductor identification, jacket requirements, packaging and other project-specific features with Zhong Hua Jiang. Final custom arrangements are subject to technical confirmation.
For a wholesale quotation, specify 22AWG × 4, required length, estimated quantity, control voltage and current, cable carrier dimensions and movement, connectors, destination and documentation requirements.
Huajiang began producing CNC spindle motors in 2000, expanding into VFDs, CNC router machines, accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 for international markets.
It contains four insulated 22AWG conductors within a shielded cable construction. The supplied specification identifies twisted stranded tinned-copper cores with PVC insulation and a PVC jacket.
The published overall jacket diameter is 5.7 ± 0.3mm. Confirm final dimensions from the product drawing before selecting a cable gland or drag chain.
The source lists a 300V rated voltage and 80°C (176°F) rated temperature. Confirm the current capacity, installation standard and operating environment separately.
The manufacturer-supplied table lists 40.1 Ω/km at 20°C. Request a measurement record for the exact cable before applying that number to electrical design.
The source says Black, White, Yellow and Green, and Red. Ask whether Yellow/Green is a single striped core and confirm the complete four-conductor assignment in the wiring diagram.
No. Verify conductor function, cable approvals and applicable machine-wiring requirements. Never substitute the overall cable shield for a required protective-earth path.
Four-core cable provides four insulated connections. Two-core and three-core options provide two and three respectively. Match conductor count to the approved equipment pinout rather than choosing by core count alone.
The product is marketed as a flexible cable-chain wire. Ask for the approved bending radius, travel length and motion data that match your machine.
The supplied technical table does not specify a numeric radius. Request installation instructions for the ordered cable instead of assuming a radius from its outside diameter.
No. A cycle figure must be interpreted with its test conditions, including radius, stroke, speed and loading. Request a model-specific test report.
Tinned copper helps reduce oxidation on exposed surfaces and is useful for soldered connections. A stranded construction can support flexibility in a properly designed cable.
An appropriately terminated cable shield can reduce coupled electrical noise in compatible control circuits. Cable separation, termination method and grounding also affect results.
No. Shielding for interference control and protective earthing for safety are different design functions. Follow the machine maker’s approved grounding instructions.
Do not assume compatibility. Spindle and VFD output wiring requires cable construction, current capacity, grounding and other characteristics selected from the drive and motor documentation.
The source does not provide impedance, capacitance or protocol compliance data. Confirm the required interface characteristics before using it for a specified communications link.
The supplied information identifies PVC insulation and jacket but does not document oil, UV or outdoor exposure ratings. Request specific evidence for the intended environment.
Product images refer to UL and the technical table mentions RoHS. Request the current certificates or declarations that identify the exact purchased model and applicable standard.
Specify 22AWG × 4, required cut or reel lengths, quantity, destination, electrical application, dynamic movement, packaging and documentary requirements.
Discuss the desired changes with the supplier and provide drawings, quantity and performance requirements so feasibility can be checked.
Use the supplier-confirmed cable outside diameter and its tolerance, the connector specification, sealing needs, strain relief and anticipated movement.