20AWG 3 Core
Zhong Hua Jiang
20AWG
5m-5000m
3
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
40.1Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 20AWG 3-conductor shielded drag chain cable is designed for compatible CNC machine-control wiring, industrial sensor connections and automation equipment that require three individually insulated conductors routed through a moving cable carrier. The cable is described as having twisted stranded tinned-copper cores, PVC insulation, a PVC outer jacket and a shielded construction for managing electromagnetic interference.
The published technical specifications identify a 300V voltage rating, an 80°C (176°F) temperature rating and an overall jacket diameter of 6.9 ± 0.3mm. Evaluate conductor count, operating current, cable run length, machine wiring diagram, environmental exposure and drag-chain movement before selecting a cable.
The specified construction contains three insulated, twisted tinned-stranded copper conductors within a PVC-insulated, PVC-jacketed shielded cable. The technical table also lists cotton rope and cotton paper as internal filling. Obtain the model-specific section drawing to confirm the overall screen construction, termination method and internal arrangement.
For OEM integration or replacement wiring, compare the number and function of each insulated core, identification colors, shield arrangement, gland or connector fit, electrical rating, permitted moving bend radius and equipment mounting environment.

Request a Quote for 20AWG 3-Core Shielded Cable
CNC builders, industrial automation integrators, repair operations and distributors can evaluate this 20AWG × 3 shielded cable for compatible three-wire sensor and control connections that must travel in a flexible cable carrier.
An appropriately installed overall screen can help reduce electromagnetic noise coupled into sensitive control wiring. Use the CNC controller and electrical drive manufacturer’s recommendations for shield bonding and separation from inverter output leads. Do not treat the overall shield as an additional insulated conductor or a protective-earth replacement.
A useful purchasing inquiry identifies the 20AWG × 3 model, required cable or reel lengths, estimated quantity, machinery or sensor type, installation method, expected chain movement, operating voltage/current and any required drawings, reports or declarations.

| Rated Voltage: | 300V | Number of Conductors: | 3 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 20AWG |
| Conductor Resistance: | 40.1 Ω/km at 20°C (as published; request verified resistance) | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green | ||
| Jacket Dia(mm): | 6.9 ± 0.3 | ||
The published conductor-resistance figure is 40.1 Ω/km at 20°C. Ask for a current model-specific cable technical sheet and conductor-resistance test when planning circuit voltage drop or comparing gauges. The dielectric-test and insulation-resistance units also need confirmation before design approval.
The supplier imagery refers to UL and the material table references RoHS. Confirm any product-specific listing, certificate or declaration, including the applicable standards and model number, before relying on these references.
Request the 20AWG 3-Core Technical Specification

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The published promotional images mention 15 million flex cycles. Actual durability depends on the tested model, dynamic bend radius, cycle speed, travel distance and installation conditions. Request applicable test records before specifying this figure in a machine design.
For moving cable systems, check the cable manufacturer’s allowed dynamic bending radius, minimum installation clearance, travel speed and strain-relief guidance. Jacket diameter alone does not establish the approved minimum bending radius.
The specified 6.9 ± 0.3mm outside diameter is relevant to cable gland sealing, connector entry and cable-carrier filling. Confirm the model drawing and movement specifications before finalizing the machine bill of materials.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
The tinned-copper strands are intended for reliable conductive connections and practical solder termination. Tin plating can improve oxidation resistance at exposed strand surfaces when compared with bare copper.
The service life of a moving cable depends on the complete conductor, shield, filler and jacket construction, as well as its cable-chain installation and operating conditions.
For circuit design and voltage-drop estimates, request verified conductor-resistance data for this exact 20AWG model and calculate the electrical path length according to the actual sensor or controller circuit.

A correctly terminated cable shield can help limit coupled electromagnetic interference from nearby motors, drives and switching devices.
Follow approved controller grounding and shield-termination instructions. Keep sensitive low-level control wiring separate from higher-noise VFD power output circuits where the equipment design specifies separation.
The shield is an electromagnetic-interference control measure. Any protective-earth conductor must satisfy the machine wiring design and applicable standards independently of the screen.
Dynamic service requires more than a nominal flex-cycle statement. Check the machine carrier bend radius, travel speed and distance, installation temperature, cable separation and termination method with the tested cable’s documentation.
Discuss Cable Carrier Installation Requirements

The three insulated cores may be considered for compatible three-wire industrial sensor circuits, CNC control wiring and switching connections that call for a screened moving cable.
Potential applications include compatible three-wire position sensors, controller signal connections and related automation circuits inside CNC routers or moving machinery. Verify each pin assignment, voltage, load current, signal compatibility and safety requirement.
Three-core construction does not automatically qualify a cable for an encoder, motion-control feedback bus, RS-485 network or VFD-to-spindle motor output. Check device cabling requirements, cable impedance where applicable, shield design, conductor ratings and approved grounding.
For wholesale or OEM orders, share the three-core wiring schedule, requested length and packaging, number of machine assemblies, planned drag-chain movement, termination details, installation environment and any model-specific compliance documentation required.
Choose conductor count according to the actual terminal diagram, not just the cable diameter. A three-core screened cable has three insulated conductors; the external screen is not a fourth insulated conductor.
All three constructions refer to the number of separately insulated conductors. A three-core version may suit certain sensor supply, signal and return connections, subject to the equipment pinout. Select the number of wires required by the device and any separate protective-earth requirement.
| Cable configuration | Number of insulated conductors | Typical selection question |
| 20AWG × 2 | Two | Does the circuit use only two conductor paths? |
| 20AWG × 3 | Three | Does the approved device diagram require three conductor paths? |
| 20AWG × 4 | Four | Does the circuit require a fourth individually insulated path? |
The published overall cable diameter is 6.9 ± 0.3mm. Check connector entries, cable gland clamping dimensions, drag-chain cable compartment clearance and the manufacturer-approved dynamic bend radius.
The listed core colors are black, white, and yellow/green. Confirm this configuration on the approved core identification drawing. Where yellow/green is reserved for protective earthing under applicable standards, do not assign it to another circuit function.
For noise-sensitive CNC sensors, follow controller guidance for cable screening and bonding. Separate screened control leads from motor-output wiring as required. Confirm that the product is suitable for the intended signal standard rather than assuming shielding alone ensures compatibility.
Send Your Three-Core Cable Requirements
Zhong Hua Jiang also lists shielded drag-chain and double-shielded electrical cable categories. Select the family based on the specified core count, conductor gauge, shielding construction, cable motion, system noise level and equipment requirements.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company supplies CNC router models including 3018, 3020, 3040 and 6090 for compatible engraving and machining work.
Its equipment range includes air-cooled and water-cooled CNC spindle motors suited to different machine and cooling configurations.
Related CNC accessories include limit switches, Z probes, emergency-stop components and other equipment control accessories.
The wire range includes moving-use shielded chain cable and other shielded electrical wiring for compatible CNC machine connections.
Stepper motors and related motion components serve compatible positioning and automation systems.
Equipment manufacturers, system integrators, importers and distributors can send their purchasing schedule, drawing, required cable length per assembly, order volume, destination, connection details and cable-carrier operating conditions for technical and quotation review.
For qualification, request the model-specific conductor configuration, color identification, tested resistance, shield construction, approved bend radius, flex-life conditions and any applicable regulatory declarations.
Request OEM / Distributor Cable Pricing

Certification and customer material may relate to different products within the company range. Ask for documents that identify the exact three-conductor cable part number being purchased.

This 20AWG three-core shielded drag-chain cable is presented for CNC machine wiring, industrial automation, sensors and moving cable carriers where the wiring diagram requires three insulated conductors.
Shielded wiring may reduce electromagnetic interference when screen bonding, cable separation and equipment grounding are executed according to the machine and controller requirements.
The product is presented for cable-chain operation. The technical table does not give a numerical minimum dynamic bend radius, test speed, acceleration or travel stroke. Obtain the applicable values before approving repetitive movement.
The published specifications identify three twisted 20AWG tinned stranded copper conductors, PVC insulation and jacket, 300V, 80°C, and a 6.9 ± 0.3mm outside diameter. The 40.1 Ω/km at 20°C conductor-resistance value should be checked against a model-specific test report.
The published core color listing is Black, White, Yellow and Green, apparently indicating black, white and one yellow/green core. Confirm the actual color arrangement in the product drawing. Yellow/green conductor identification is subject to applicable protective-earth color conventions.
Tinned stranded copper supports electrical conduction, solderability and resistance to surface oxidation; repeated-bending capability also depends on jacket, shielding and movement parameters.
Discuss requested cable lengths, packaging, core color identification or other OEM requirements with the supplier and obtain technical confirmation before changing the ordered specification.
For quotation, supply 20AWG × 3, order volume, desired lengths, machine or sensor wiring diagram, operating voltage/current, cable-carrier dimensions, connector or gland requirements and destination.
Huajiang started with CNC spindle motor production in 2000 and expanded into machine tools, VFDs, accessories and electrical cabling. The Zhong Hua Jiang brand was established in 2018 for international markets.
It is a shielded electrical cable with three twisted 20AWG insulated tinned-stranded copper conductors and PVC insulation and jacket for compatible machine wiring.
The manufacturer-published outer diameter is 6.9 ± 0.3mm. Check the technical drawing for gland entry and cable carrier clearance.
The published technical table states 300V and 80°C (176°F). The installation and load-current requirements must be checked separately.
The published product specification lists 40.1 Ω/km at 20°C. Obtain a test record or an approved cable datasheet for this model before using that value in electrical calculations.
Black, white and yellow/green are listed. Confirm whether yellow/green denotes a striped conductor and verify the final wiring schedule.
Do not reassign it where yellow/green is reserved for protective earth by applicable wiring standards. Use the approved machine wiring design and the manufacturer’s core identification.
A three-core cable contains three insulated conductor paths instead of two. Choose the number required by the sensor or controller terminal diagram.
When the connection diagram requires four separate paths, choose an approved four-core construction rather than trying to use the shield as another conductor.
It is marketed for drag-chain use, but the approved dynamic bend radius, carrier travel, movement speed and tested construction should be verified for the exact order.
A numerical dynamic bending radius is not specified in the published table. Request an installation limit supported by the manufacturer’s documentation.
The product illustrations display this flex-cycle figure without defining its test conditions. Request the relevant test record before treating the figure as an expected service life.
Stranding improves cable conductor flexibility versus solid wire, while the tin coating can help with exposed-surface oxidation and solder termination.
An appropriately installed and bonded screen can limit coupled noise. Shielding effectiveness depends on termination, routing and the machine electrical environment.
No. It is not an additional insulated core and cannot automatically replace a protective-earth conductor required by the equipment safety design.
Do not presume so. VFD motor-output cables need to be selected from motor current, drive voltage, conductor cross-section, EMC and protective-earthing requirements.
It may be evaluated for compatible sensors if voltage, conductor assignment, signal format, connector design and current ratings match the device instructions.
The published table provides no verified characteristic impedance or encoder-specific data. Check the protocol and device cabling requirements before selecting it.
The published specifications identify a PVC jacket but does not provide these exposure classifications. Obtain tested performance data if oil, UV, water or chemicals are present.
UL references and RoHS material descriptions appear in the product materials; request valid cable-specific supporting documentation and standard numbers.
Provide the expected cable lengths, quantities, packaging requirements and any design modifications for confirmation of feasibility and commercial terms.
Provide 20AWG × 3, lengths, quantity, shipment destination, cable-carrier conditions, application, pinout or wiring schedule and any required technical documents.
Quick Links
Contact Us