22AWG 6 Core
Zhong Hua Jiang
22AWG
5m-5000m
6
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
40.1Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22AWG 6-conductor shielded drag chain cable is intended for compatible CNC controllers, industrial sensor circuits, machine-control connections and automated cable carrier assemblies. Six twisted stranded tinned-copper conductors with PVC insulation and a shielded PVC jacket provide multiple insulated wiring paths in a compact cable.
This 22AWG six-core configuration is listed with a 300V voltage rating, 80°C (176°F) temperature rating and 6.3 ± 0.3mm overall jacket diameter. Check the machine wiring diagram, conductor current, cable length and operating movement before specifying it for equipment.
Request a 22AWG Six-Core Cable Quote
The cable description identifies six stranded tinned-copper conductors and PVC insulation within a shielded jacket. It also lists cotton rope and cotton paper filling. Obtain the actual model cross-sectional drawing to confirm core arrangement and screen construction.
For repeat OEM orders, check cable dimensions, six-core conductor identification, electrical resistance, shield termination, dynamic bend-radius requirements and product documentation. Match the supplied wiring schedule to the end device and moving cable chain.

This shielded 22AWG six-core cable can be evaluated for compatible six-wire sensor connections, low-current CNC control circuits, limit-switch assemblies and multi-signal automation wiring where flexible cable-carrier routing is required.
The overall shield may help control coupled electromagnetic interference when the cable is correctly installed and bonded. Keep sensitive control wiring appropriately separated from VFD motor leads. The shield is not a seventh insulated wire or a substitute for protective earthing.
For industrial purchasing, specify 22AWG × 6, needed cable length and quantity, cable carrier travel and bend requirements, voltage and current, six-wire color map, terminations, packaging and delivery destination.

| Rated Voltage: | 300V | Number of Conductors: | 6 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 22AWG |
| Conductor Resistance: | 40.1 Ω/km at 20°C (as published; verify test report) | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green, Red, Green, Blue | ||
| Jacket Dia(mm): | 6.3 ± 0.3 | ||
The supplier lists conductor resistance as 40.1 Ω/km at 20°C. Obtain a current six-core cable test report before using this figure to determine loop voltage drop or maximum signal run length.
The data sheet also lists insulation resistance and dielectric testing with units that should be confirmed by the cable manufacturer. For UL and RoHS documentation, request records showing the exact cable part number and applicable standard.
Request Six-Core Cable Technical Details

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The cable is marketed for moving drag-chain installations. Promotional material mentions 15 million bending cycles, but actual mechanical life depends on testing and operating conditions; obtain the relevant test report before using a cycle count as a design limit.
Check the cable manufacturer’s minimum dynamic bend radius, drag-chain travel distance, speed, acceleration, installation clearance and strain relief. No single bend-radius value can be reliably inferred from the outside diameter alone.
The published 6.3 ± 0.3mm outside diameter is relevant when selecting cable-carrier clearance, connector entry and strain relief. Verify current production tolerances and the allowable dynamic bend radius against a model-specific cable drawing.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned stranded copper combines electrical conductivity with practical solder termination and resistance to oxidation at exposed strand surfaces.
Cable service life depends on conductor stranding, jacket construction, bend radius, carrier travel and installation conditions.
Use the verified conductor resistance and total run length to assess voltage drop and signal integrity for the actual circuit.

The cable shield can help reduce unwanted electromagnetic interference from adjacent electrical equipment when correctly installed.
For sensitive control and sensor circuits, check the machine maker’s instructions for shield termination, separation from motor-output cables and electrical bonding.
A cable shield does not replace a dedicated protective-earth conductor. Follow the machine’s approved safety and grounding design.
Product graphics mention 15 million flex cycles. Cable-carrier service life also depends on bend radius, travel, speed, acceleration, cable load and termination. Obtain the measured test configuration before using a cycle rating in the equipment design.
Discuss Cable Carrier Requirements

A six-core shielded cable option for compatible multi-signal and low-current control wiring in moving CNC equipment and industrial automation cable carriers.
Examples for engineering evaluation include multi-conductor CNC controller harnesses, suitable sensor and switch circuits, automation equipment and cable-carrier connections. Confirm the device’s actual power, signal and safety requirements before installation.
Six insulated 22AWG conductors offer six separate current paths in one shielded cable. The construction alone does not certify compatibility with a particular encoder, serial communication bus, emergency stop safety loop or high-frequency VFD output.
For a tailored quotation, provide wire gauge, six-core diagram, required cable lengths and volumes, voltage/current, drag-chain stroke and bending conditions, termination type, installation environment and expected documentation.
Select the number of insulated conductors from the real equipment connection plan. The metallic shield is separate from the six internal conductors and must not replace any required protective-earth circuit.
Compare core count first, then check insulation ratings, outside diameter, movement, conductor loading, termination and the cable’s actual electrical behavior.
| Cable option | Number of insulated cores | Typical selection question |
| 22AWG × 4 | 4 | Does the device require four separate wires? |
| 22AWG × 5 | 5 | Does the device require five separate wires? |
| 22AWG × 6 | 6 | Does the device require six separate wires? |
The specified outside diameter is 6.3 ± 0.3mm. Measure cable-carrier space, strain relief and connector entry. Ask for the actual permitted dynamic bending radius and chain travel conditions rather than choosing a bend radius from the jacket diameter alone.
The published conductor colors read Black, White, Yellow and Green, Red, Green, Blue. Ask whether Yellow/Green represents a single striped core, and obtain a clear drawing of all six conductors. Use the machine’s approved protective-earth arrangement; never assume the cable shield is an earth conductor.
Confirm electrical current, conductor length, permissible voltage drop, shielding arrangement and relevant sensor or controller connection. The listed conductor resistance requires product-specific verification before it is used as an engineering limit.
Send Six-Conductor Cable Requirements
Explore the shielded drag-chain and double-shielded wire ranges from Zhong Hua Jiang. Compare conductor count, wire gauge, moving versus fixed installation and cable dimensions before selecting an equivalent wiring product.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company offers CNC router machine configurations such as 3018, 3020, 3040 and 6090 for engraving, cutting and related machining work.
The product range includes air-cooled and water-cooled spindle motors for different CNC machine power and cooling requirements.
CNC accessories include limit switches, Z probes, emergency-stop buttons and related machine-control parts.
The electrical wire range includes shielded drag-chain cables for moving applications and other shielded wire constructions for equipment wiring.
Stepper motors are used for controlled positioning in compatible CNC and automation systems.
For OEM projects, machine maintenance or distributor sourcing, state the six-core wiring diagram, requested cable length, order quantity, application environment, cable-chain movements, packaging and delivery destination.
Ask for an approved part-number drawing, conductor-color map, shielding construction, test report and any applicable material or conformity records before qualifying this cable for a new machine build.
Request OEM / Distributor Pricing

Certification and company material can cover several product families. Request documents specifically identifying the 22AWG six-conductor cable when qualification is required for your purchase.

This cable is presented for six-conductor, 22AWG machine-control and sensor applications, including moving cable carrier routes. Evaluate circuit loading, shielding, flexible installation and interference susceptibility against the final wiring design.
Shielding helps limit coupled electrical noise near drives, switching devices and power cables when installed correctly. Route and terminate the shield according to the controller and equipment manufacturers’ requirements.
The product is presented for cable-carrier movement. However, minimum dynamic bend radius, working speed, stroke length and flex-test conditions are not stated in the supplied technical table. Request these data for the specific ordered cable.
The product specifications identify six twisted 22AWG stranded tinned-copper cores, 300V and 80°C ratings, PVC insulation and jacket, and a 6.3 ± 0.3mm overall diameter. The published 40.1 Ω/km at 20°C requires verification against a test report for this cable model.
The conductor-color description reads Black, White, Yellow and Green, Red, Green, Blue for this six-core cable. Confirm whether Yellow/Green designates one striped insulated conductor and verify all six positions against a wiring diagram before termination.
Tinned stranded copper combines useful conductivity, solderability and oxidation resistance at strand surfaces. Flexibility and service life depend on the complete cable construction and operating conditions.
Discuss cable length, conductor identification, jacket requirements, packaging and other project-specific features with Zhong Hua Jiang. Final custom arrangements are subject to technical confirmation.
Include 22AWG × 6, order volume, cut length or reel length, control-circuit pinout, expected motion, required connector or cable gland, destination and documentation requirements in your inquiry.
Huajiang began producing CNC spindle motors in 2000, expanding into VFDs, CNC router machines, accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 for international markets.
A six-core cable with six insulated 22AWG twisted stranded tinned-copper conductors, PVC insulation and jacket, and a shielding layer for suitable CNC and automation control wiring.
The supplied product table lists 6.3 ± 0.3mm. Use the approved dimension drawing when choosing connectors, cable glands and drag-chain compartments.
The product table lists 300V and 80°C (176°F). The current limit for an actual circuit depends on installation, termination and the applicable electrical design.
The original table gives 40.1 Ω/km at 20°C. Request a model-specific test report before using this value for voltage-drop calculations.
The published line reads Black, White, Yellow and Green, Red, Green, Blue. Ask for the six-core color map to confirm whether Yellow/Green is one striped wire.
Use the equipment wiring diagram and applicable safety rules to identify any protective-earth conductor. Do not infer actual core assignment from an ambiguous color description.
It provides six insulated conductors instead of four or five. Use the number of wires required by the approved sensor, controller or machine connection diagram.
The product is described for electrical cable-chain installations. Confirm the approved moving bend radius, travel, acceleration and other installation limits for the exact cable.
The uploaded product specification does not give a minimum dynamic bend radius. Obtain this value from the manufacturer for the actual installation.
The marketing material lists this figure without full test conditions. Ask for the tested bend radius, speed, travel, loads and pass/fail criteria before using the claim in design calculations.
Tin plating helps protect exposed copper strands from oxidation and can support solderability. Flexible performance also depends on conductor stranding and the entire cable construction.
When properly installed and terminated, a shield can help reduce unwanted electromagnetic interference. Cable separation, grounding and source of interference still matter.
No. A signal cable screen does not replace an independently designed protective-earth path where required by the machine safety system.
Do not assume suitability. A VFD motor-output circuit needs a cable selected for the drive, motor, voltage, current, grounding, shielding and installation limits.
Conductor count and shielding alone do not demonstrate compatibility with a particular encoder or communications standard. Check impedance, capacitance, pair construction and device specifications.
PVC is listed for insulation and jacket, but no oil, moisture, chemical or UV performance classification is provided. Obtain tested values if these properties are required.
Product imagery refers to UL, and material entries mention RoHS. Request current supporting documents identifying the exact cable model and applicable standard.
Provide a six-core connection drawing, revised material or length requirements and projected order volume to discuss whether the changes can be supplied.
Specify 22AWG × 6, application, cable length, order quantity, required technical documents, cable-chain conditions, packaging and shipping location.
Choose connector glands and strain relief using the 6.3 ± 0.3mm stated outside diameter, the termination type and the movement and sealing requirements of the equipment.