16AWG 5 Core
Zhong Hua Jiang
16AWG
5m-5000m
5
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
13.7Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 16AWG 5-conductor shielded drag chain cable is designed for moving cable carriers, CNC machines and industrial automation equipment. The cable combines five twisted tinned-stranded copper conductors, PVC insulation, a shielded construction and a flexible PVC jacket for machine wiring that requires repeated movement.
This 16/5 shielded chain cable has a listed 300V voltage rating, 80°C temperature rating and 9.8 ± 0.3mm outer diameter. It can be considered for compatible control, sensor, actuator and auxiliary-power circuits after the actual electrical load, cable-carrier movement and installation requirements are checked.
Request 16AWG 5-Core Cable Pricing
The cable uses five twisted 16AWG insulated conductors with conductor identification as detailed on the approved drawing. Tinned stranded copper offers practical solder termination and protection against surface oxidation, while the surrounding shield helps manage interference around drives, switching devices and controllers.
The cable construction includes PVC insulation and outer jacket, together with cotton rope and cotton paper as internal separation or filling materials. Before approving a machine harness, confirm the complete cable drawing, shield construction, cable length, connection requirements and the operating environment.

For CNC equipment manufacturers, automation integrators and electrical distributors, this 16AWG five-core shielded chain cable provides a practical cable option when the equipment wiring diagram calls for five conductors. Specify the required five-wire circuit, voltage and current, along with movement and shielding needs.
The shielding can help limit electromagnetic interference in electrical systems that operate near VFDs, motor drives, power supplies or control panels. Correct shield termination, conductor routing and enclosure bonding are important; the shielding should never substitute for a separately required protective-earth connection.
Contact Zhong Hua Jiang to discuss cable length, purchasing volume, core identification, packing arrangements, machine type and any project-specific construction requirements. Final cable selection should be based on the approved technical data for the intended installation.

| Rated Voltage: | 300V | Number of Conductors: | 5 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 16AWG |
| Conductor Resistance: | 13.7Ω/KM 20°C | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green, Red, Green | ||
| Jacket Dia(mm): | 9.8 ± 0.3 | ||
The published color description is Black, White, Yellow and Green, Red, Green for the five-conductor cable. Check the approved wiring diagram to establish whether Yellow/Green identifies a single two-color core and how the separate Green core is designated before making electrical connections. The technical specification lists an insulation resistance of 10 MΩ/km at 20°C and a dielectric test of “2000AC V/min”; confirm the test method, units and acceptance criteria using the current cable test document.
Request a Cable Drawing and Quote

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The drag-chain construction is intended for repeated bending in moving cable carriers. Product literature mentions 15 million flex cycles, but the applicable test conditions need to be checked for the exact ordered cable and its installation.
Confirm cable-carrier compatibility before installation, including minimum dynamic bend radius, travel stroke, speed, acceleration, available chain space, strain relief and operating temperature.
A flexible conductor alone does not determine service life. The cable construction, carrier layout, bending stress and installation practices all affect reliability over time. Request the relevant flex-life test documentation when the machine specification sets a minimum cycle requirement.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned copper facilitates soldering and helps reduce oxidation of exposed strands.
Long-term electrical and mechanical performance depends on conductor construction and operating conditions.
Select the cable using measured resistance, conductor size and the required termination method.

The cable shield helps manage electromagnetic interference that could otherwise affect sensitive control or signal circuits.
For CNC and automation wiring, follow the equipment manufacturer’s EMC instructions on shield termination, grounding and cable separation.
A shield is an interference-control component, not a protective-earth conductor. Provide the required protective bonding separately.
The product literature cites 15 million flex cycles. Actual operating life cannot be established from a headline cycle count alone; request the cable-specific test procedure, bend radius, travel stroke, speed, acceleration and environmental conditions.
Discuss Drag Chain Cable Requirements

Designed for shielded five-conductor connections in equipment that uses moving cable carriers.
Potential applications include CNC control wiring, automation systems, sensors, actuators and moving-machine auxiliary circuits, subject to electrical and mechanical compatibility.
The five insulated conductors can serve compatible control, sensor, low-voltage supply or return circuits in CNC routers, engraving equipment, robotic mechanisms and other automation machines. For VFD spindle motor power, evaluate the motor-output cable specification separately rather than assuming a five-core control cable is sufficient.
For machine wiring projects, provide the required core count, operating current, voltage, drag-chain bend radius, stroke length, travel speed, shielding termination, installation environment and expected order volume. Cable length, jacket and packaging options can then be discussed.
Choose the core count from the equipment wiring diagram, then verify operating current, voltage, required shield construction, dynamic bend radius, cable-carrier environment and termination hardware. This 16/5 cable supplies five insulated conductors, each with a stated 16AWG gauge; do not count the shield as another current-carrying conductor.
All three designations use nominal 16AWG conductors, but the core count differs. A 16/4 cable contains four insulated conductors, 16/5 contains five, and 16/6 contains six. Use the count required by the wiring diagram, and compare each specific product’s outer diameter, bending requirements and electrical limits before ordering.
| Cable designation | Core count | Typical selection criterion |
| 16AWG × 4 | 4 cores | Circuits that require four insulated 16AWG conductors |
| 16AWG × 5 | 5 cores | Circuits that require five insulated 16AWG conductors |
| 16AWG × 6 | 6 cores | Circuits that require six insulated 16AWG conductors |
This cable has a stated nominal outer jacket diameter of 9.8 ± 0.3mm. Confirm that the drag-chain channel, gland or connector, strain relief and dynamic minimum bend radius are compatible with the cable. Provide travel length, speed, acceleration and installation temperature when requesting technical guidance.
A cable shield helps control electromagnetic coupling when correctly connected; it is not a substitute for a required protective-earth conductor. For any VFD-to-spindle or other motor-output connection, verify the cable is specifically rated for the motor voltage, drive-output waveform, conductor arrangement and equipment EMC requirements. Do not assume this 300V shielded chain cable is a universal VFD motor-output cable.
Send Your Wiring Diagram for Cable Selection
Explore Zhong Hua Jiang shielded chain cables and other shielded electrical wire constructions. Choose between dynamic-motion chain cables and fixed-installation shielded cables based on the specific circuit and cable-carrier requirements.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company describes more than 20 years of manufacturing experience in CNC products and holds design patent No. 200730184245.5 for an air-cooled spindle-motor series. This company background is separate from model-specific electrical cable approvals.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
CNC router machines such as 3018, 3020, 3040 and 6090 are included in the company’s product range for engraving, cutting and related machining applications.
Air-cooled and water-cooled CNC spindle motors are offered for different machine power, speed, cooling and integration requirements.
The CNC accessory range includes limit switches, Z probes, emergency-stop buttons and related components for machine setup and control.
The electrical wire range includes shielded drag-chain cables for moving applications and other shielded cables for suitable equipment wiring.
Stepper motors are available for controlled positioning in CNC machines and related automation applications.
For equipment manufacturers, machine integrators, importers and distributors, request a quotation for the precise 16AWG five-conductor configuration. Supply the cable length per cut or reel, total order quantity, machine model, operating current and voltage, core colors, drag-chain motion data, packaging and shipping destination.
Where your project requires traceability or compliance evidence, request the current cable specification sheet, product drawings, test reports and any recognition or compliance files that apply to the exact ordered part number.
Request OEM or Wholesale Pricing

The documents shown above may cover different product families. Verify the listed cable’s markings and request model-specific compliance or UL recognition documents, where required for the destination market or equipment standard.

This 16AWG five-core shielded chain cable is intended for CNC machines, cable carriers, automation equipment, sensor or controller circuits and moving-machine wiring where five insulated conductors are required. Verify electrical and motion compatibility for the specific use.
A shielded cable can reduce interference coupling from motor drives, VFDs, power supplies and other nearby electrical equipment when the shield is properly terminated. Cable routing and the complete EMC installation still affect the result.
It is presented as a cable for moving drag-chain applications. The actual dynamic bend radius, installation method and maximum flex life must be checked against the purchased cable’s documentation and the cable-carrier operating conditions.
The published cable data specifies five twisted 16AWG tinned-copper conductors, 300V and 80°C (176°F) ratings, PVC insulation and jacket, and a 9.8 ± 0.3mm outer diameter. Confirm conductor colors against the wiring diagram.
The product description lists Black, White, Yellow and Green, Red, Green for five cores. Verify whether Yellow/Green is one striped conductor and whether the additional Green is a separate conductor. Do not assign circuit or protective-earth functions from color alone.
Tinned stranded copper provides electrical conductivity, useful solderability and improved resistance to oxidation at exposed strand surfaces. The multi-strand construction also supports cable flexibility.
Cable length, core colors, packaging and application-specific construction requirements can be discussed. Provide an equipment drawing and the intended operating conditions to determine whether the requested configuration is available.
Specify the 16AWG × 5 conductor configuration, cable length, quantity, operating voltage and current, drag-chain bend radius and travel stroke, connector or termination, required documentation and delivery destination.
Huajiang was founded in 2000 as a CNC spindle motor manufacturer and later expanded to VFDs, CNC machines, accessories and electrical wiring products. The Zhong Hua Jiang brand was introduced in 2018 for international markets.
16/5 means five insulated 16AWG conductors. The supplied data describes five twisted tinned-stranded copper cores, PVC insulation and an overall shield for cable-chain wiring.
The stated cable diameter is 9.8 ± 0.3mm. The selected cable carrier, cable gland, connector and strain relief should be checked against this dimension.
The published ratings are 300V and 80°C (176°F). The permitted operating current must be determined from the equipment design, installation conditions and applicable cable documentation.
The listed conductor resistance is 13.7 Ω/km at 20°C. Account for cable length, loop resistance, current and permitted voltage drop when selecting a control or auxiliary circuit.
The published color list is Black, White, Yellow and Green, Red, Green. Before wiring, confirm with the supplied drawing whether Yellow/Green means one striped core and whether Green is an additional separate core.
The listing describes five twisted conductors, not separately rated twisted pairs. If a circuit requires specific pair geometry or characteristic impedance, obtain the detailed cable construction from the supplier.
It is marketed for moving drag-chain use. Verify the dynamic bend radius, stroke, speed, acceleration and installation method against the exact cable before equipment approval.
A numeric minimum bend radius is not supplied in the published table. Request the manufacturer’s dynamic and static bend-radius recommendations for your machine installation.
The product marketing references 15 million flex cycles, but this is not a universal lifetime guarantee. Verify the test conditions, bend radius, travel stroke, movement speed and end-of-life criterion for the actual model.
Not on the basis of its core count and shield alone. Verify spindle voltage and current, VFD output cable suitability, protective-earth requirements, insulation and EMC installation instructions first.
Follow the machine, control system and drive manufacturer’s EMC installation guidance. The preferred shield connection can depend on the equipment design, and the shield must not replace a required protective-earth conductor.
The source does not specify impedance-controlled twisted pairs. Confirm the required pair geometry, characteristic impedance, operating environment and signal integrity before using this cable for a particular fieldbus.
Yes. The published material specification lists PVC insulation and a PVC outer jacket with tinned stranded copper conductors; cotton rope and cotton paper are also listed within the cable construction.
The supplied source identifies PVC as the jacket material but does not state an oil, UV, outdoor or chemical exposure rating. Request specific resistance data or another jacket construction when required.
The product materials mention UL and RoHS, but the exact model-specific documents are not supplied. Ask for the applicable UL record, current compliance declarations or test reports for the purchased part number.
Custom length, jacket, color, labeling and packaging options can be discussed. Provide the cable construction drawing, desired quantity and end-use requirements for confirmation and a quotation.
Supply the 16AWG five-core specification, required cut or reel lengths, purchase quantity, equipment application, operating current and voltage, drag-chain movement data, destination market and requested documentation.
Quick Links