You are here: Home » Products » Shielded Wire » Double Shielded cable » 14AWG » Zhong Hua Jiang 14AWG 4-Core Double-Shielded Cable

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Zhong Hua Jiang 14AWG 4-Core Double-Shielded Cable

Zhong Hua Jiang 14AWG 4-core double-shielded cable uses tinned stranded copper, aluminum foil and copper shielding with PVC insulation, 300V/80°C ratings and a 9.6mm outer jacket.
  • 14AWG 4 Core

  • Zhong Hua Jiang

  • 14AWG

  • 5m-5000m

  • 4

  • Tinned stranded copper

  • PVC(RoHS)

  • 300V

  • 80℃/176℉

  • 9.25Ω/KM20℃

  • >10MΩ/KM20℃

  • 12A

Availability:

14 AWG 4-Conductor Double-Shielded Cable

14 AWG 4 conductor double shielded electrical wire for CNC and control wiring

Zhong Hua Jiang 14 AWG 4-Conductor Double-Shielded Cable contains four twisted tinned stranded copper conductors with PVC insulation, an aluminum foil shield, a tinned-copper shield and a PVC outer jacket. Designed for appropriate machine control, equipment interconnections and auxiliary circuits, its shielding helps limit electromagnetic interference when correctly installed and terminated. This configuration is suited to equipment builders, system integrators, electrical-component distributors and OEM procurement teams.

The published configuration specifies a 300V voltage rating, 80°C temperature rating, 12A current figure, 9.25 Ω/km conductor resistance at 20°C and a 9.6 ± 0.3 mm jacket diameter. The 12A figure is not a universal allowable current for every installation: final capacity and cable suitability depend on circuit type, installation method, ambient temperature, grouping, voltage drop and local requirements.

Cross-section layout of 14 AWG 4 core double shielded wire

14 AWG 4-Core Shielded Cable for Industrial Buyers

This 14 AWG 4-core cable is intended for buyers who need four individually insulated conductors, a tinned stranded copper construction and two layers of electromagnetic shielding. Black, red, yellow and white conductor insulation assists identification during assembly and servicing; the actual function assigned to each core must follow the machine wiring diagram.

Compared with an unshielded cable, a correctly terminated foil-plus-copper shielding system can reduce electromagnetic noise coupling in suitable installations. Actual effectiveness depends on shielding coverage, connectors, termination, routing and the frequency of the interfering signals; the cable should not be assumed to have a particular shielding attenuation without test data.

Zhong Hua Jiang lists available cable lengths from 5 m to 5,000 m. OEMs, equipment builders, importers and wholesale distributors can submit their requested lengths, quantities, installation details, core assignments and labeling or packaging preferences for quotation and feasibility confirmation.

Request 14/4 Shielded Wire Pricing

14 AWG 4-Conductor Cable Specifications

14 AWG 4 conductor electrical double shielded wire product view

14 Gauge 4 Conductor Wire

Rated Voltage 300V Number of Conductors 4 twisted conductors
Rated Temperature 80°C / 176°F Wire Size 14 AWG
Conductor Resistance 9.25 Ω/km at 20°C Conductor Material Tinned stranded copper
Insulation Resistance >10 MΩ/km at 20°C Foil Orientation One-side aluminum, aluminum facing outward
Electric Current 12A Insulation Material PVC (RoHS)
Material Structure PVC + tinned copper + aluminum Jacket Material PVC (RoHS)
Conductor Colors Black, red, yellow and white
Jacket Diameter 9.6 mm ± 0.3 mm
Available Length 5 m to 5,000 m

For accurate selection, confirm the required cable length, working current, voltage, conductor assignment, bend requirement, shielding termination and equipment electrical specifications before ordering. The listed 12A current rating should be checked against installation temperature, cable length, bundling, voltage drop and applicable electrical standards.

Important measurement details: The specification lists insulation resistance as >10 MΩ/km at 20°C. Request the applicable test procedure, unit convention and acceptance criteria if insulation resistance is a purchasing requirement. The published 12A figure should likewise be verified for the final operating conditions.

Request 14 AWG 4-Core Technical Details

14/4 Double-Shielded Cable Features

UL2464 14 AWG 4 core double shielded wire tinned copper structure

UL2464 Style Reference - Verify Documents Aluminum + Tinned-Copper Double Shielding Tinned Copper Core

Why Choose Our Wire

Shielded cable conductor and insulation structure

Oxidation-resistant tinned copper wire icon Low eccentricity shielded cable icon High conductivity tinned copper cable icon PVC insulation resistance icon
Oxidation Resistance Low Eccentricity High Conductivity Insulation Resistance

High Conductivity

At an equivalent conductor material and temperature, a larger 14 AWG cross-section generally has lower resistance than thinner 16 AWG, 18 AWG or 20 AWG conductors. Tin plating supports solderability and reduces surface oxidation; it does not mean tinned copper has inherently higher bulk conductivity than an equally sized bare copper conductor.

Advantage of Tinned Copper
Comparison Item Tinned copper conductorTinned Copper Bare pure copper conductorPure Copper Copper clad aluminum conductorCCA
Copper-Clad Aluminum
Easy to Solder Recommended conductor feature Standard conductor feature Standard conductor feature
Conductivity of Copper Conductors Recommended conductor feature Recommended conductor feature Standard conductor feature
Anti-Oxidation Recommended conductor feature Standard conductor feature Standard conductor feature
Anti-Corrosion Recommended conductor feature Standard conductor feature Standard conductor feature
Sturdy and Durable Recommended conductor feature Standard conductor feature Standard conductor feature

Conductor comparison note: The pictures and icon matrix above illustrate common material attributes rather than measured performance of these exact constructions. Bare copper is also conductive and solderable; plating, conductor grade, wire size, surface condition and process control affect performance.

The tinned-copper construction supports solderability and resistance to surface oxidation; actual service life depends on installation and environmental conditions.

Double Shielded Layer

Aluminum and tinned copper double shielded layer for 14 AWG 4 core cable

This cable combines an aluminum foil screen and a tinned-copper shield surrounding its four insulated conductors. The combination can help reduce external electromagnetic interference and coupling between neighboring conductors and equipment when the cable is routed and terminated correctly.

In practical equipment wiring, the cable shield should be terminated according to the controller, VFD, motor or machine manufacturer's grounding and EMC instructions. The shield is used for interference control and should not be treated as a replacement for a required protective-earth conductor.

14/4 Cable Construction and EMI Control

Four insulated 14 AWG conductors: Black, red, yellow and white tinned stranded copper cores are arranged within a PVC insulating system. The four-core arrangement is useful where a circuit needs multiple defined conductors but does not, on its own, specify power, signal or protective-earth functions.

Foil plus copper shielding: An aluminum screen and a tinned-copper layer help limit coupled electrical noise. Correct shield termination, suitable connector design, enclosure bonding and separation from high-noise power wiring are essential for the intended EMC performance.

PVC outer sheath: The listed overall diameter is 9.6 ± 0.3 mm. Confirm cable entry glands, connector boots, routing space and actual minimum bend radius with the manufacturer before installation. No continuous-flex or drag-chain life rating is specified in the supplied product data.

Discuss EMI Shielding and Cable Construction

Applications of 14 AWG 4-Core Shielded Wire

14 AWG 4 conductor shielded wire for transformer connections 14 AWG 4 conductor shielded wire for electronic instruments
Transformer Electronic Instrument
14 AWG 4 conductor shielded wire for electrical appliances 14 AWG 4 conductor shielded wire for motors and CNC control equipment
Electrical Appliance Motor

The 14/4 cable may be evaluated for internal and interconnection wiring in CNC equipment, machine controls, instrument panels, electronic equipment, auxiliary motor circuits and other applications where the cable ratings and applicable installation requirements are satisfied. Intended use must be confirmed against the equipment specification, applicable wiring rules and the required cable classification.

For new-machine assembly or replacement wiring, review the rated voltage and temperature, conductor loading, shielding connection, fixed versus moving installation, and whether the end product requires a specialized cable class. For continuous motion or VFD output power, obtain an application-specific cable recommendation rather than assuming this standard shielded cable is suitable.

Choosing 14/4 vs 14/3, 16/4 and 18/4 Cables

14/4 vs 14/3: Both use 14 AWG-size conductors, but the 14/4 version provides four insulated cores instead of three. The added core supports a fourth conductor position when required by the equipment wiring design.

14/4 vs 16/4 or 18/4: All three configurations can offer four conductors, but a larger 14 AWG copper cross-section generally reduces conductor resistance at equivalent length and temperature. Smaller gauges may be preferred where cable diameter, weight, routing space and circuit current allow. Select based on actual voltage drop, load and machine requirements rather than gauge alone.

Standard shielded cable vs drag-chain cable: Shielding addresses electromagnetic noise; continuous flex life is a separate mechanical design requirement. Where cables run through moving energy chains, ask for a product explicitly rated for the required motion and bending cycles.

Compare 14/4 Cable and Other Wire Gauges

Zhong Hua Jiang shielded electrical wire product range

Get 14 AWG 4-Core Cable Bulk Pricing

Other Shielded Cable Options

In addition to this 14 AWG four-conductor double-shielded configuration, Zhong Hua Jiang offers cable categories for different wiring requirements. Select between general-purpose shielded cable and products intended for moving cable chains according to the equipment motion and electrical specification.

Company Profile

Zhong Hua Jiang CNC spindle motor and electrical wire manufacturer

Electrical Shielded Wire Manufacturer

Zhong Hua Jiang manufacturing company profile

How We Started

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.

What Makes Us Proud

The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.

Why Choose Us

Zhong Hua Jiang quality assurance, patents and brand advantages
Quality Assurance
Product inspection and quality-control procedures before shipment.
Patents and Certifications
Long-term CNC manufacturing experience and patented spindle designs.
Additional Brand Value
Integrated product support for CNC machines, spindles, accessories and wiring.
Zhong Hua Jiang price, service and delivery advantages
Reasonable Price
Direct factory communication for specifications, quantities and custom lengths.
Full Time Service
Technical support for cable gauge, conductor count and application selection.
Fast and Reliable Delivery
Production coordination, shipment updates and export-order service.

Leading CNC Machine / CNC Spindle Motor Manufacturer Since 2000

Our Product Range

CNC Router Machines

CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.

CNC Spindle Motors

Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.

CNC Accessories

The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.

Electrical Wires

Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.

Stepper Motors

Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

OEM and Wholesale Cable Ordering Guide

For a more accurate procurement review, specify 14 AWG / four conductors, the requested total length or cut lengths, annual or project volume, operating voltage and current, cable routing conditions, required connector or termination method, destination market and any customer drawing or cable marking requirements.

For electrically sensitive equipment, also provide the type of electrical noise source, shielding termination approach, nearby motor or VFD arrangement and any installation constraints. If certification, RoHS documentation, flame performance or a specific cable marking is required, identify it in the inquiry and request matching records for the ordered configuration.

Request OEM and Wholesale Cable Quotation

Product Certification

Zhong Hua Jiang shielded wire product certification document

Certification and compliance requirements vary by market and end use. For any order requiring UL AWM Style 2464, RoHS declarations or other conformity documentation, request the relevant product-specific records, manufacturer identification and current test documents for review before purchase. A style designation does not independently establish certification of this exact cable.

Customer Feedback

Customer feedback for Zhong Hua Jiang shielded electrical wire

Send Your 14/4 Wiring Requirements

FAQ

What is 14 AWG 4 conductor electrical double shielded wire used for?

It is used for four-core higher-current control, auxiliary power and low-voltage equipment wiring where EMI reduction is important. Typical applications include CNC machines, VFD-related control circuits, motor auxiliary wiring, electronic instruments, transformers, power-limited control systems, security wiring, lighting control, audio/control signal paths and monitoring circuits.

What does 14/4 shielded cable mean?

“14/4” means the cable contains four insulated 14 AWG conductors. In this product, the four conductors are twisted and protected by aluminum and tinned-copper shielding layers inside an overall PVC jacket.

What are the voltage, temperature and current ratings?

The listed rated voltage is 300V, the listed rated temperature is 80°C / 176°F and the listed current is 12A. Final suitability depends on circuit design, voltage drop, load type, installation environment, cable length, bundling and applicable standards.

How does double shielding improve EMI resistance?

The aluminum foil and tinned-copper shielding layers form conductive barriers around the insulated conductors. When terminated correctly, these layers help reduce interference from motors, VFDs, switching power supplies and other noise sources, improving stability in sensitive control or auxiliary-power wiring.

Should the cable shield be grounded at one end or both ends?

Shield termination depends on the equipment, frequency range, enclosure bonding and EMC design. Follow the CNC controller, VFD, motor or equipment manufacturer's wiring instructions. The cable shield should not replace a required protective-earth conductor.

What is the difference between 14/4 and 14/3 shielded wire?

Both products use 14 AWG conductors, but 14/4 provides four insulated cores while 14/3 provides three insulated cores. Choose 14/4 when the circuit needs an additional conductor for common, feedback, brake, signal reference, control return, four-wire sensor wiring or multi-signal equipment connections.

Is 14 AWG 4 core shielded wire suitable for motor or VFD wiring?

It can be used for suitable motor auxiliary, feedback, brake, sensor or low-voltage control circuits when the electrical requirements match the cable rating. For main motor power, VFD output power or safety-critical wiring, confirm cable type, insulation rating, shielding method and applicable standards before use.

Is this cable suitable for drag-chain or continuous-motion use?

Standard flexible shielded cable may be suitable for fixed or occasional-flex installations. Continuous high-cycle motion generally requires a cable specifically designed for drag chains. Provide bend radius, travel distance, speed and cycle frequency so the proper cable type can be confirmed.

Can the length and packaging be customized?

Yes. The available length range is 5 m to 5,000 m. Buyers can provide the required roll length, total quantity, packing preference, labeling needs, application and destination market for quotation confirmation.

What information should I provide when requesting a quote?

Provide the cable gauge, conductor count, required length, estimated quantity, voltage, current, equipment model, installation movement, conductor-color requirement, termination method and delivery destination. These details help confirm the right cable and produce an accurate quotation.

How does Zhong Hua Jiang control product quality?

The company describes product-quality checks before dispatch. For project acceptance, agree on the product-specific inspection scope and documents required for your order, such as cable specification, dimensional tolerances, test results and any required certification records.

Are four 14 AWG cores the same as two twisted pairs?

No. The specification describes four twisted conductors; it does not establish two individually shielded twisted pairs or a defined pair lay. Buyers needing twisted-pair impedance or pair-to-pair isolation should request a detailed construction drawing.

What are the conductor colors and the outer cable diameter?

The published colors are black, red, yellow and white. The PVC jacket outside diameter is listed as 9.6 mm ± 0.3 mm. Each conductor should be assigned according to the equipment wiring diagram; colors alone do not define earth or polarity functions.

What is the published conductor resistance for the 14 AWG cable?

The product table lists 9.25 Ω/km at 20°C. Cable-length and circuit-resistance calculations should account for the complete supply-and-return path, contact resistance and the selected operating temperature.

Is the published 12A current figure an installation rating?

The source specification lists 12A. The permitted continuous current for a specific installation is not determined from this figure alone. Check applicable electrical rules, conductor temperature, ambient conditions, cable grouping, load and voltage drop.

Can the shielding braid serve as the protective-earth conductor?

No. The metallic shields are provided to manage electromagnetic interference. Any required protective-earth or bonding conductor must comply with the equipment design and applicable electrical rules; the shield must not be assumed to replace it.

Does a UL2464 style reference mean this cable is UL certified?

Not by itself. UL AWM Style 2464 is a construction and use category reference. For compliance-sensitive procurement, confirm the actual manufacturer, file or recognition details, marking and current product-specific records before ordering.

Is a RoHS declaration available for the PVC insulation and jacket?

The supplied specification identifies both PVC components as RoHS. Ask for a current, product-specific declaration and supporting documentation if compliance is required by your customer or destination market.

Can this four-core cable be used for VFD output or main motor power?

Do not assume suitability from gauge, conductor count and double shielding alone. Main VFD-output and motor-power circuits may require specialized insulation, cable geometry, termination and grounding features. Follow the VFD and motor manufacturer cable recommendations.

How should shielding be terminated for best EMC performance?

Termination depends on the controller, electrical-noise frequencies, equipment bonding and enclosure design. Use the equipment manufacturer instructions, compatible connectors and appropriate shield bonding. One-end versus two-end termination should not be chosen without reviewing the system.

What are the available wire lengths for bulk orders?

The product data lists a range of 5 m to 5,000 m. Confirm exact cut lengths, packaging formats, production feasibility and order quantities for the required configuration through the sales team.

What documents should an industrial distributor request?

Request the current product drawing or datasheet, material and conductor information, outer-diameter tolerance, voltage/temperature limitations, required regulatory declarations and product-specific recognition documents where applicable.

Why choose 14 AWG instead of 16 AWG or 18 AWG?

A 14 AWG copper conductor has a larger nominal cross-section than 16 AWG or 18 AWG, generally giving lower conductor resistance at equal length and temperature. The trade-off may be greater size and weight; confirm the cable construction and actual circuit requirements.

Contact Zhong Hua Jiang for Pricing and Custom Lengths

Previous: 
Next: 

Product Category

Apply Our Best Quotation

Global Recruitment of Authorised Agents!

Join us as an exclusive distributor of CNC Router Machines and CNC Spindle Motors. As a professional manufacturer, we provide high-performance machines, attractive profit margins, technical training, and full marketing support. Build a strong partnership with us and expand your market with confidence.

Products

Quick Links

Contact Us

   zhonghuajiang@huajiang.cn
  +86-13915011877
   No.379-2, Hengyu Road, Henglin town, Wujin District, Changzhou, Jiangsu, China
© COPYRIGHT 2025 CHANGZHOU HUAJIANG ELECTRICAL CO.,LTD ALL RIGHTS RESERVED.