You are here: Home » Products » Shielded Wire » Shielded Chain cable » 16AWG » Zhong Hua Jiang 16AWG 6-Core Shielded Drag Chain Cable

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Zhong Hua Jiang 16AWG 6-Core Shielded Drag Chain Cable

Zhong Hua Jiang 16AWG 6-core shielded drag chain cable features tinned stranded copper, PVC insulation and jacket, 300V/80°C ratings and a 10.7mm diameter for CNC equipment wiring.
  • 16AWG 6 Core

  • Zhong Hua Jiang

  • 16AWG

  • 5m-5000m

  • 6

  • Tinned stranded copper

  • PVC(RoHS)

  • 300V

  • 80℃/176℉

  • 13.7Ω/KM20℃

  • 10MΩ/KM20℃

  • 2000AC V/min

Availability:

16AWG 6-Core Shielded Drag Chain Cable

Zhong Hua Jiang 16 gauge 6 conductor electrical chain shielded wire

Zhong Hua Jiang 16AWG 6-core shielded drag chain cable brings six insulated tinned-stranded copper conductors into a flexible PVC-jacketed construction. Developed for CNC equipment, cable carriers and machine-control installations, the shielding helps limit electromagnetic interference when the cable is installed and terminated correctly.

The product listing specifies 300V, 80°C, a 10.7 ± 0.3mm jacket diameter and 13.7 Ω/km conductor resistance at 20°C. These details help machine builders, electrical distributors and OEM buyers compare the cable with existing control wiring and moving cable assemblies.

Get a Quote for 16AWG 6-Core Chain Cable

16AWG 6-Core Cable Construction and Shielding

Six stranded tinned-copper conductors form the cable core, with PVC insulation, cotton rope and cotton paper used in the stated construction. The shielding helps manage electromagnetic interference. For a machine wiring drawing, confirm the exact shield material, coverage, drain-wire arrangement and termination method for the ordered cable.

For cable carrier use, evaluate the cable together with the carrier bend radius, travel distance, acceleration, operating speed and routing method. A flexible construction alone does not establish a universal flex-cycle rating; request the applicable test conditions for the intended installation.

electrical shielded wire structure for CNC and automation wiring

Shielded Drag Chain Cable for CNC and OEM Equipment

This 16/6 shielded chain cable is intended for industrial buyers who need six separate circuits in one jacket, shielding near electrical noise sources and a cable format suitable for planned drag-chain routing. It may be considered for control signals, permitted auxiliary circuits and automation wiring after electrical loading and local installation requirements are checked.

Compared with unshielded cable, a correctly connected shield can improve noise management around drives, switches, motors and automation controllers. The cable is not automatically suitable for every VFD-to-spindle power connection: verify conductor current capacity, insulation system, shield construction and drive manufacturer guidance.

Common procurement projects include OEM CNC router assemblies, replacement harnesses, control cabinets, moving gantry wiring and distributor stock programs. Share the required installed length, cable carrier dimensions and target electrical loads when requesting a quotation.

16AWG 6-Conductor Chain Cable Specifications

This 16AWG six-core configuration is specified at 300V and 80°C, with a 10.7 ± 0.3mm cable outer diameter. For technical acceptance, request the cable drawing and relevant electrical and dynamic-flex test records for your intended machine installation.

15FT 16AWG 6 core electrical chain shielded wire

16 Gauge 6 Conductor Wire

Rated Voltage:

300V

Number of Conductors:

6 Twisted

Rated Temperature:

80°C / 176°F

Size:

16AWG

Conductor Resistance:

13.7Ω/KM 20°C

Conductor Material:

Tinned Stranded Copper

Insulation Resistance:

10MΩ/KM 20°C

Insulation Material:

PVC (RoHS)

Dielectric Test:

2000AC V/min

Isolation Material:

Cotton Rope and Cotton Paper

Material:

PVC + Tinned Copper

Jacket Material:

PVC (RoHS)

Conductor Color:

Black, white, yellow/green, red, green and blue (confirm the six-core identification drawing)

Jacket Dia(mm):

10.7 ± 0.3

The conductor-color information includes black, white, a yellow/green identification, red, green and blue. Confirm the six-core color arrangement and terminal mapping before ordering. Conductor resistance is specified as 13.7 Ω/km at 20°C; review the cable drawing and test method if resistance is critical to circuit design.

Request 16AWG 6-Core Cable Specifications

Technical Checklist for Machine Builders

Conductor identification Six cores; obtain the final color-to-function drawing and terminal mapping
Electrical suitability Confirm voltage, load current, permitted installation conditions and cable length
Dynamic installation Confirm minimum bend radius, carrier travel, acceleration, service loop and bend test conditions
Noise management Confirm shield type, coverage, bonding and separation from power cables
Order details Specify length per assembly or reel, quantity, packaging and destination market

Features of Shielded Chain Cable

UL pass high flexibility shielded tinned copper core advantages

UL Documentation: Verify for This Cable High-Flex Cable: Test Conditions on Request Shielded Tinned Copper Core

For UL status or a stated flex-cycle rating, request the document covering the exact cable model. Confirm certification markings, test bend radius, travel length and duty conditions before making a production selection.

Why Choose Our Wire

why choose Zhong Hua Jiang shielded chain wire

oxidation resistance shielded wire low eccentricity electrical wire high conductivity tinned copper wire insulation resistant shielded cable
Oxidation Resistance Low Eccentricity High Conductivity Insulation Resistant

Extreme Flexible Cable

extreme flexible 16AWG 6 conductor chain cable

High-Flex Drag Chain Cable — Verify Test Conditions

Compatible with Chain System

The stranded conductor and chain-cable design support repeated movement when the cable is installed within its specified operating limits. For high-cycle duty, confirm the test bend radius, stroke, acceleration, temperature and number of cycles supported by the relevant report.

High Conductivity

Advantage of Tinned Copper


tinned copper conductor pure copper conductor copper clad aluminum conductor

Tinned Copper

Pure Copper

CCA

Copper Clad Aluminum

Easy to Solder

yes icon no icon no icon

Better Conductivity

yes icon yes icon no icon

Anti-oxidation

yes icon no icon no icon

Anti-corrosion

yes icon no icon no icon

Sturdy and Durable

yes icon no icon no icon

Tinned copper can improve solderability and resistance to surface oxidation. Electrical resistance and flex life depend on the conductor cross-section, tinning, strand design and operating environment. Select cable materials using the approved technical specification.

Tinned Copper Offers Excellent Conductivity

Prolonging Service Life

More Suitable for Soldering

Chain Shielded Wire

16AWG 6 conductor chain shielded wire structure

The shielding helps protect against electromagnetic interference.

Shielding reduces interference only when installed with appropriate bonding and routing. It does not substitute for a protective-earth conductor or permit operation outside the rated cable limits.

This is important for maintaining signal integrity in CNC and automation wiring.

Shielded cables can also support grounding protection in suitable electrical designs.

Industrial Applications for 16AWG 6-Core Cable

For high-motion applications, work from the machine cable schedule and carrier operating data rather than selecting only by AWG size. The shielding system, cable diameter and available bend radius all affect routing suitability.

application of electrical chain shielded wire for CNC and automation equipment

Designed for flexible, durable, and interference-resistant electrical wiring.

Suitable for CNC machines, drag chains, automation equipment, control systems, and signal wiring.

Potential applications include CNC router cable carriers, axis-control wiring, automated machinery, machine sensors, motion-control equipment and equipment refurbishment. Each installation must be assessed for voltage, current, temperature, conductor assignment, electrical noise and mechanical bending stress.

For alternate requirements, contact Zhong Hua Jiang with the required 16AWG conductor configuration, desired cable length, shield termination, PVC-jacket expectations, installation environment and packaging needs. Any nonstandard configuration should be confirmed in the quotation and drawing.

Discuss Bulk Cable and OEM Requirements

       Zhong Hua Jiang electrical shielded wire product category    

How to Select 16AWG Shielded Cable for Moving Equipment

Select a cable by the number of required circuits, conductor gauge, operating voltage, permissible current and shield construction. For moving installations, the dynamic bend radius, travel distance, speed, acceleration, ambient conditions and chain guidance are equally important.

16/6 Versus 16/4 and 18/6 Cable

A 16/6 cable provides six insulated 16AWG cores; 16/4 provides four conductors of the same nominal gauge. An 18/6 cable offers six cores with a smaller nominal conductor size. Compare electrical load, cable diameter and movement requirements rather than choosing by conductor count alone.

Cable Carrier Installation and EMC Protection

Do not twist the cable during drag-chain installation. Confirm the manufacturer-approved minimum bend radius, provide appropriate strain relief, observe carrier fill requirements and terminate the shield according to the drive or controller manufacturer’s EMC instructions. The shield does not replace a protective-earth conductor.

For a quotation, specify 16AWG × 6 cores, cable length per unit or reel, purchase quantity, equipment type, application voltage and current, drag-chain bend radius, travel stroke, travel frequency, operating conditions, end termination and destination market.

Other Shielded Wire and Cable Options

Ask About OEM Cable Supply

Explore other shielded drag-chain cables and double-shielded cable options to compare conductor count, wire gauge, mobility requirements and shielding construction for your CNC or automation project.

About Zhong Hua Jiang

Zhong Hua Jiang supplies CNC machine components and electrical accessories to equipment manufacturers, distributors and export buyers. Its shielded cable product range supports machine wiring and cable management projects.

Zhong Hua Jiang company profile

ELECTRICAL CHAIN SHIELDED WIRE MANUFACTURER

Zhong Hua Jiang company avatar

How We Started?

Huajiang was founded in 2000, starting with the production of CNC engraving spindle motors, and later expanded production to VFDs, engraving machines, CNC accessories, and electrical wiring solutions.

To explore and develop more global markets, we established the brand Zhong Hua Jiang in 2018.

What Makes Us Proud?

We have a registered patent for our air cooling spindle motor series. Patent No: 200730184245.5.

We have more than 20 years of manufacturing experience in CNC spindle motors, CNC machine products, and related electrical accessories.

Our products have been exported to customers worldwide, including markets in the USA and Germany.

WHY CHOOSE US

quality assurance patents and brand value

Quality Assurance

Superior quality performance

Strict quality control

Patents and Certifications

Several patents for air-cooled

spindle motors

Additional Brand Value

Brand value highly recognized

by the market

reasonable price service and delivery

Reasonable Price

Direct factory sales

High cost performance

Full Time Service

Professional technical support

Quick customer service

Fast and Reliable Delivery

Fast and efficient delivery

Real-time tracking and updates

LEADING CNC MACHINE / CNC SPINDLE MOTOR MANUFACTURER SINCE 2000

OUR PRODUCT RANGE

CNC Router Machines

Zhong Hua Jiang CNC router machines, including models such as 3018, 3020, 3040, and 6090, are designed for engraving, cutting, and precision machining projects.

CNC Spindle Motors

Our air-cooled and water-cooled spindle motors are designed for CNC routers and engraving machines requiring stable rotation, precision, and durability.

CNC Accessories

We also supply CNC accessories such as limit switches, Z probes, emergency stop buttons, and related electrical components for CNC machine operation.

Electrical Wires

Our electrical wire range includes shielded chain cables and double-shielded cables designed to reduce signal interference and support reliable machine wiring.

Stepper Motors

Our stepper motors provide precise control for CNC machines, automation equipment, and other motion control systems.

Product Documentation and Certifications

Certification images are provided for reference. For acceptance of this specific 16AWG 6-conductor cable, request the applicable UL record, material declarations or relevant test report and confirm that the document matches the supplied construction.

product certification for Zhong Hua Jiang shielded wire and CNC products

Customer Feedback

Reference material from customer interactions is shown below. Contact the sales team for documentation and product-specific details relevant to your project.

customer feedback for Zhong Hua Jiang electrical shielded wire

Frequently Asked Questions About 16AWG 6-Core Cable

Find answers about conductor count, shielded control wiring, moving cable carriers, voltage ratings, cable dimensions and purchasing requirements.

What is 16 Gauge 6 Conductor Electrical Chain Shielded Wire used for?

The six-core shielded cable is used in CNC machines, cable carriers, automation equipment, control panels, sensor circuits and moving machine wiring. Assess current, voltage, shielding termination and movement conditions against the machine specification.

Why choose shielded wire instead of ordinary unshielded wire?

Shielded wire helps reduce electromagnetic interference from motors, VFDs, controllers, and other electronic devices. This helps maintain signal integrity in CNC and automation wiring systems.

Is this 16AWG 6 conductor cable suitable for drag chains?

It is offered for chain-cable applications. Final suitability depends on the manufacturer-approved dynamic bend radius, number of bending cycles, travel length and operating environment. Confirm these data for your equipment.

What are the main specifications of this 16/6 shielded cable?

This cable contains six twisted 16AWG tinned-stranded copper conductors, PVC insulation and an outer PVC jacket. The specified rated voltage is 300V, rated temperature is 80°C and jacket diameter is 10.7 ± 0.3mm.

Why does this electrical chain wire use tinned stranded copper?

The tin coating helps protect copper strands against surface oxidation and can improve solderability. Strand construction provides flexibility; fatigue resistance depends on the full cable design and operating conditions.

Can Zhong Hua Jiang provide custom shielded wire solutions?

Cable length, conductor colors, shield requirements and packaging may be discussed with the supplier. Final technical feasibility, quantities and commercial terms should be confirmed in the quotation.

How do I request a quote for 16 Gauge 6 Conductor Shielded Chain Wire?

Send the required total cable length, quantity, six-conductor assignment, expected voltage and current, cable carrier dimensions, operating conditions and destination market. The team can review the proposed configuration and provide a quotation.

What does 16AWG 6-core mean?

It identifies a cable with six individually insulated conductors, each described as 16 American Wire Gauge. The corresponding metric conductor size and stranding should be confirmed on the drawing when international interchangeability is required.

What voltage and temperature ratings are shown for this cable?

The cable is specified at 300V and 80°C (176°F). Its allowable current is not determined by the voltage rating alone; verify conductor loading, ambient temperature, installation method, grouping and applicable electrical standards.

What is the outside diameter of the 16AWG six-core shielded cable?

The specified outer jacket diameter is 10.7 ± 0.3mm. Check the drag-chain internal dimensions, minimum cable bend radius and connector or cable-gland clamping range before purchasing.

What is the stated conductor resistance at 20°C?

The product table lists 13.7 Ω/km at 20°C. Ask the supplier to identify the tested conductor area and method if resistance is important for voltage-drop or circuit calculations.

How should the cable shielding be connected?

The method depends on the equipment grounding and EMC design. A qualified installer should confirm whether the shield is bonded at one or both ends, the termination geometry and separation from noisy power circuits.

Can this shielded cable be used between a VFD and CNC spindle?

Not solely on the basis of being shielded. Confirm the VFD manufacturer’s cable requirements, operating voltage, conductor ampacity, shield construction and grounding arrangement before using it as a motor power cable.

Is the cable rated for 15 million bending cycles?

Product promotional material refers to 15 million flex cycles. Actual service life depends on the cable carrier, bend radius, stroke, acceleration, temperature and test criteria. Ask for the applicable cable-specific dynamic-flex test report before relying on this figure in a production specification.

Is this 16AWG 6-core wire UL certified?

UL-related product material is displayed, but certification should be checked for the exact ordered cable. Request its applicable UL file or recognition record and verify the cable marking against that documentation.

Which conductor colors are included?

Core colors are described as black, white, yellow/green, red, green and blue. Request a cable drawing or core-color schedule to confirm which core uses the yellow/green identification before cable harness assembly.

Is this wire suitable for moving robotics or CNC gantries?

It is marketed for flexible chain-cable routing, but suitability for an individual robotic axis or gantry requires a check of motion geometry, torsion, bend radius, movement frequency and cable-carrier restrictions.

What are the differences between shielded chain cable and ordinary double-shielded cable?

A chain cable is selected with repeated flexing in mind, while shielding describes EMI protection. A double-shielded cable may be unsuitable for constant movement unless its construction and test data support that duty.

What purchasing information should a distributor or OEM provide?

Provide the conductor count and gauge, length, annual or order quantity, cable carrier parameters, destination country, expected electrical loading, color configuration, required documentation and packaging preferences.

Who is the supplier of this 16AWG six-core shielded chain cable?

Founded in 2000, Zhong Hua Jiang has over 20 years of experience in CNC engraving spindle motors and has expanded its product range to include VFDs, engraving machines, CNC accessories, stepper motors, and electrical wire products.

Does a 16AWG six-conductor cable contain six twisted pairs?

No. “16AWG × 6” identifies six insulated conductors, not six pairs or three separately specified balanced pairs. If a communication protocol requires a defined twisted-pair geometry or characteristic impedance, request the appropriate cable construction and electrical data.

Can I use the shield as a protective-earth conductor?

No. The shielding is intended for electromagnetic interference management. Protective bonding and grounding must use the conductors and installation methods required by the machine design and relevant electrical standards.

What determines minimum bend radius and cable life in a drag chain?

Minimum bend radius and service life depend on strand design, jacket materials, cable diameter, movement speed, acceleration, stroke length and environmental conditions. Confirm the specified chain bend radius and request cable-specific dynamic test data.

Can the cable carry three-phase VFD power to a CNC spindle?

Six conductors alone do not establish that the cable is suitable for a VFD motor-output circuit. Verify the motor current, voltage, insulation and shield design, EMC installation rules and protective-earth arrangement required by the VFD and spindle manufacturer.

What does a 13.7 Ω/km conductor resistance mean for cable selection?

The stated conductor resistance is 13.7 Ω/km at 20°C. Assess conductor run length and load current when calculating resistive voltage drop and heating, and use the installation-specific allowable current rather than inferring current capacity from AWG alone.

Request Wholesale Pricing for 16AWG 6-Core Cable

Previous: 
Next: 

Product Category

Apply Our Best Quotation

Global Recruitment of Authorised Agents!

Join us as an exclusive distributor of CNC Router Machines and CNC Spindle Motors. As a professional manufacturer, we provide high-performance machines, attractive profit margins, technical training, and full marketing support. Build a strong partnership with us and expand your market with confidence.

Products

Quick Links

Contact Us

   zhonghuajiang@huajiang.cn
  +86-13915011877
   No.379-2, Hengyu Road, Henglin town, Wujin District, Changzhou, Jiangsu, China
© COPYRIGHT 2025 CHANGZHOU HUAJIANG ELECTRICAL CO.,LTD ALL RIGHTS RESERVED.