22AWG 4 Core
Zhong Hua Jiang
22AWG
5m-5000m
4
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
59.4Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22 AWG 4-Conductor Double-Shielded Cable is a four-core electrical cable for compatible CNC controllers, automation panels, instrumentation and low-voltage control or signal circuits. Four insulated tinned stranded-copper conductors are twisted within an aluminum and tinned-copper double-shielded construction, with PVC insulation and a PVC outer jacket. This configuration is intended for OEM equipment builders, distributors and professional installers requiring four separate conductors and interference protection.
The published ratings include 300V, 80°C (176°F), 59.4 Ω/km conductor resistance at 20°C and a 5.2 ± 0.20 mm cable outer diameter. The four individually insulated conductor colors are black, red, yellow and white. Confirm the signal interface, wiring diagram, mechanical conditions, shield termination and all applicable installation requirements before specifying the cable.

This 22/4 double-shielded control cable provides four insulated 22 AWG cores in one compact jacket, making it a candidate for suitable control-panel connections, machine auxiliary controls, low-power sensor interfaces and electronic-instrument wiring. Individual conductor colors aid identification during harness assembly and maintenance; actual core functions are defined by the equipment wiring diagram.
The aluminum layer and tinned-copper shielding layer help limit electromagnetic interference when properly terminated. Tinned stranded copper offers good solderability and resistance to surface oxidation. Shielding performance is influenced by connection quality, cable routing, bonding and the electromagnetic environment; double shielding does not guarantee immunity to all interference.
For industrial OEM orders, maintenance projects or wholesale requirements, send the required cut or reel length, quantity, application, connector or gland dimensions and destination market. Discuss any nonstandard labeling, packaging or conductor configuration with Zhong Hua Jiang for availability and quotation confirmation.
Request 22/4 Shielded Wire Pricing
Request 22/4 Shielded Cable Wholesale Pricing

| Rated Voltage | 300V | Number of Conductors | 4 twisted conductors |
| Rated Temperature | 80°C / 176°F | Wire Size | 22 AWG |
| Conductor Resistance | 59.4 Ω/km at 20°C | Conductor Material | Tinned stranded copper |
| Insulation Resistance | 10 MΩ/km at 20°C | Foil Orientation | One-side aluminum, aluminum facing outward |
| Dielectric Test | 2000 VAC/min | Insulation Material | PVC (RoHS) |
| Material Structure | PVC + tinned copper + aluminum | Jacket Material | PVC (RoHS) |
| Conductor Colors | Black, red, yellow and white | ||
| Jacket Diameter | 5.2 ± 0.20 mm | ||
| Available Length | 5 m to 5,000 m | ||
Engineering note: The supplied table lists insulation resistance as 10 MΩ/km at 20°C and the dielectric test as 2000 VAC/min. Confirm the measurement units, test conditions and acceptance criteria in the manufacturer’s current data sheet. The 300V insulation rating is not a statement of permissible conductor current; assess voltage drop and ampacity for the actual installation.
Request 22 AWG 4-Core Cable Specifications and Quote
For accurate selection, confirm the required cable length, conductor assignment, signal type, voltage, current, bend requirement, shielding termination and equipment electrical specifications before ordering. For continuously moving cable-carrier applications, verify whether a dedicated shielded chain cable is required.

| AWM Style 2464 Reference — Confirm Exact Cable Documentation | Aluminum + Tinned-Copper Double Shielding | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistance |
The four conductors are specified as tinned stranded copper with a published resistance of 59.4 Ω/km per conductor at 20°C. Tin plating aids solderability and protects copper surfaces against oxidation. It does not make copper inherently more conductive than bare copper of the same cross-section. For electrical sizing, check conductor resistance, required current, temperature, circuit length and connector suitability.
| Advantage of Tinned Copper | |||
| Comparison Item | Tinned Copper | Pure Copper | CCACopper-Clad Aluminum |
| Easy to Solder | |||
| Copper Conductor | |||
| Anti-Oxidation | |||
| Anti-Corrosion | |||
| Sturdy and Durable | |||
The material-comparison images are general illustrations, not product-specific comparative laboratory results. For supplier qualification, use the cable data sheet, measured resistance, conductor identification and relevant test documentation rather than graphical checkmarks alone.
Tinned stranded copper combines copper conductivity with tin-plated surfaces that support soldering and oxidation resistance.

An aluminum layer and a tinned-copper shielding layer enclose the insulated cores to help manage electromagnetic coupling from nearby motor drives, relays and switching devices. The effectiveness of this construction depends on shielding continuity, termination, enclosure bonding, cable placement and noise frequency.
Terminate the shielding according to the CNC controller, VFD, instrumentation or machine manufacturer’s EMC instructions. One-end versus both-end bonding depends on the specific system; do not use the cable shield in place of a required protective-earth conductor. Keep sensitive control wiring appropriately separated from motor power cables whenever practicable.
Discuss Cable Shielding and OEM Requirements
![]() | ![]() |
| Transformer | Electronic Instrument |
![]() | ![]() |
| Electrical Appliance | Motor |
This four-conductor cable can be evaluated for suitable CNC controller inputs and outputs, equipment status and auxiliary control circuits, sensor connections, compact electronic instruments, automation panels and low-voltage monitoring systems. Use the approved wiring diagram to assign each conductor. For RS-485, CAN, encoder feedback or other defined communication links, verify whether the system requires individually twisted pairs, controlled impedance, specified capacitance and dedicated shielding construction.
A four-core control cable is not automatically interchangeable with a four-conductor motor-power or VFD output cable. Similarly, conventional flexible shielding does not establish continuous-motion drag-chain suitability. Select the final wiring type according to electrical load, flex cycle, bending radius, ambient conditions and manufacturer approval.
Check This Cable for Your Equipment
Choosing the correct cable requires matching the number of insulated cores, electrical characteristics, shielding method and mechanical conditions to the actual equipment circuit. Four conductors can carry four separately assigned connections, but four cores do not necessarily mean two individually twisted differential pairs.
| Selection Factor | 22 AWG 4-Core Configuration / Buyer Check |
|---|---|
| Conductors | Four twisted 22 AWG tinned stranded-copper conductors; black, red, yellow and white identification. |
| Published electrical ratings | 300V; 80°C; 59.4 Ω/km at 20°C. Verify conductor current and circuit voltage drop. |
| Cable entry and routing | 5.2 ± 0.20 mm listed jacket diameter; confirm gland sealing range, bend requirements and installed clearances. |
| EMI shielding | Aluminum and tinned-copper layers; verify continuity, grounding method and cable separation. |
| Electrical interface | Confirm circuit pinout and whether individually twisted signal pairs, characteristic impedance or capacitance limits apply. |
| Sourcing details | Length per cut or reel, order quantity, packaging, destination, labeling and document requirements. |
The published 20°C conductor resistance is 59.4 Ω/km, equivalent to 0.0594 Ω/m per conductor. In a two-wire supply-and-return circuit, approximate resistance for the conductors is 2 × one-way run length × 0.0594 Ω/m. Multiply by circuit current to estimate voltage drop at 20°C, before allowing for termination resistance or conductor-temperature effects. Validate the actual conditions and applicable installation rules.
Send Your 22/4 Wiring Requirements
| Cable Type | Core Count / Relative Gauge | Selection Consideration |
|---|---|---|
| 22 AWG 4-core (this cable) | Four insulated 22 AWG conductors | For compatible four-connection signal and low-power control circuits. |
| 22 AWG 2-core | Two insulated 22 AWG conductors | For circuits requiring only two signal or control connections. |
| 22 AWG 5-core | Five insulated 22 AWG conductors | For a wiring diagram requiring one more insulated conductor. |
| 20 AWG 4-core | Four insulated 20 AWG conductors | Larger conductor cross-section, generally lower resistance than 22 AWG with comparable construction; verify its model-specific diameter. |
The right selection depends on the cable’s internal lay, noise environment, intended communication signal, installation movement and electrical loads. Do not assume that different gauges or core counts are interchangeable simply because the jacket or connector fits.
Compare Four-Core Shielded Cable Configurations
Alongside this 22 AWG 4-core double-shielded cable, Zhong Hua Jiang offers other conductor sizes, core counts and shielded cable configurations for compatible machine control and electrical-equipment connections. Confirm the specifications and intended use of each model before selection.

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.
The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.
![]() | ||
| Quality Assurance Product inspection and quality-control procedures before shipment. | Patents and Certifications Long-term CNC manufacturing experience and patented spindle designs. | Additional Brand Value Integrated product support for CNC machines, spindles, accessories and wiring. |
![]() | ||
| Reasonable Price Direct factory communication for specifications, quantities and custom lengths. | Full Time Service Technical support for cable gauge, conductor count and application selection. | Fast and Reliable Delivery Production coordination, shipment updates and export-order service. |
CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.
Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.
The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.
Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.
Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

The original literature refers to UL2464-style construction and PVC (RoHS). A wiring-style reference or a general certificate illustration does not establish recognition or compliance for every supplied model. Ask the supplier for product-specific markings, the applicable UL file or certification record where relevant, current material declarations and any test evidence required by the destination market.
Request Model-Specific Cable Documents

It is intended for compatible four-core signal, control and low-power equipment connections where interference control matters. Examples for evaluation include CNC machine I/O, auxiliary control circuits, electronic instruments, sensor interfaces and automation panels. Confirm the electrical requirements and wiring diagram for each application.
The designation 22/4 identifies four insulated 22 AWG conductors. This cable lists four twisted conductors and aluminum plus tinned-copper shielding layers under a PVC jacket. It does not by itself confirm two individually twisted pairs.
The listed voltage rating is 300V and the listed temperature rating is 80°C (176°F). The jacket outer diameter is 5.2 ± 0.20 mm and conductor resistance is 59.4 Ω/km at 20°C. The allowable current must be determined for the actual installation.
The combination of aluminum and tinned-copper shielding can reduce unwanted electromagnetic coupling when correctly installed. Actual effectiveness depends on shield coverage, bonding, terminations, wiring layout and the frequencies of nearby interference sources.
There is no universal rule. Bonding at one or both ends depends on the controller, enclosure, grounding arrangement and EMC requirements. Follow the system manufacturer’s documentation. The shield is not a replacement for a protective-earth conductor.
Both describe four insulated conductors, but 18 AWG has a larger conductor cross-section than 22 AWG and generally a lower electrical resistance for comparable copper construction. Select based on current, voltage drop, cable routing and the exact model specifications.
It is primarily a small-gauge control and signal cable. Some low-power circuits may be suitable if the equipment design and applicable rules allow them. The 300V insulation rating does not determine ampacity; check current, heating, length, bundling and voltage drop.
The published product details do not establish a continuous-flex cycle rating. For CNC moving axes and high-cycle cable carriers, select a cable with confirmed chain-duty construction, bend radius, travel, speed and service-life suitability.
The supplied specifications list available lengths from 5 m to 5,000 m. Tell the sales team the required cut or reel length, total order quantity, packing method and label requirements so availability and any customization can be confirmed.
Provide 22 AWG, four cores, required length per piece or reel, total quantity, equipment and signal type, operating voltage, current, bend or motion requirements, connector needs, shipment country and required certification documents.
Buyers should confirm the applicable production inspection criteria and request the current model-specific data sheet, available quality records and any required test or compliance documentation for the exact order.
Not necessarily. The source specifications describe four twisted insulated conductors but do not identify two independent twisted pairs. Ask for the cable lay drawing if your circuit requires a specific pair structure.
Some RS-485 networks require controlled-impedance twisted-pair cable. This listing does not specify characteristic impedance or independent pair construction; select it only after checking the transceiver and system-cable requirements.
Only after confirming the applicable interface specifications, cable pairing, impedance, shielding, cable length and mechanical duty. Four insulated conductors alone do not qualify a cable for CAN or differential encoder signals.
The listed overall jacket diameter is 5.2 ± 0.20 mm. Verify the compatible cable gland, strain relief and connector entry range before assembly.
The listed colors are black, red, yellow and white. Conductor colors aid identification but do not assign electrical functions without the approved equipment wiring diagram.
Both have 22 AWG insulated conductors. The 22/4 configuration has four cores; 22/5 has five. Select the required conductor count according to the number of signals, supplies, returns and common connections in the circuit.
With comparable material and construction, 20 AWG has a larger cross-sectional area and generally lower electrical resistance than 22 AWG. The 22 AWG version may suit more compact low-current wiring, subject to the overall cable and connector requirements.
The published conductor resistance is 59.4 Ω/km at 20°C. For a two-conductor supply-and-return loop, calculate approximate loop resistance from twice the one-way cable length and 0.0594 Ω/m, then multiply by current. Adjust for actual temperature and termination resistance.
Sensitive signal wiring should be routed and separated as recommended by the machine or drive manufacturer. Proper bonding and shielding can help, but long parallel runs next to high-noise motor-power cables may increase interference.
No. A reference to AWM Style 2464 alone does not verify that the supplied model has an applicable UL file or recognition. Request the exact product identification, markings and relevant certification evidence.
Those values appear in the published table as insulation resistance and dielectric test. The original listing does not provide complete test conditions or unit definitions, so request the current manufacturer test method before using them as acceptance criteria.
Tin plating improves solderability and helps resist surface oxidation; it does not inherently increase the conductivity of equivalent bare copper. Verify performance using the stated conductor resistance and actual conductor construction.
The source lists cable lengths from 5 m to 5,000 m. Reel sizes, cut lengths, export packaging and labeling should be quoted for the specific requested order.
Request the model-specific specification, PVC material and RoHS documentation where applicable, any recognized-product certification records and relevant inspection or dielectric-test reports needed in the destination market.
Quick Links