Zhong Hua Jiang 14AWG 3-core double-shielded cable uses three tinned stranded copper conductors, aluminum and copper shielding, PVC insulation, a 300V/80°C rating and a 9.0mm jacket.
  • 14AWG 3 Core

  • Zhong Hua Jiang

  • 14AWG

  • 5m-5000m

  • 3

  • Tinned stranded copper

  • PVC(RoHS)

  • 300V

  • 80℃/176℉

  • 9.25Ω/KM20℃

  • >10MΩ/KM20℃

  • 12A

Availability:

14 AWG 3-Conductor Double-Shielded Cable

14 AWG 3 conductor double shielded electrical wire for CNC and control wiring

Zhong Hua Jiang 14 AWG 3-conductor double-shielded cable uses three twisted, tinned stranded copper conductors, PVC core insulation, an aluminum foil shield, a tinned-copper shielding layer and a PVC outer jacket. The three-core construction is intended for appropriate machine controls, auxiliary electrical circuits and equipment interconnections where conductor size and electromagnetic interference must be considered. It is relevant to industrial OEMs, machine builders and electrical distributors.

The published specification identifies a 300V voltage rating, 80°C (176°F) temperature rating, 9.25 Ω/km conductor resistance at 20°C, 9.0 ± 0.3 mm jacket diameter and a 12A listed current figure. That current figure is not a universal installation ampacity. Confirm the actual permissible loading, voltage drop, ambient temperature and cable grouping before specifying the cable for equipment.

Request 14AWG 3-Core Cable Pricing

Cross-section layout of 14 AWG 3 core double shielded wire

14 AWG 3-Core Shielded Cable for Industrial Buyers

This three-core 14/3 shielded cable combines conductor cross-section with foil-and-copper screening for suitable control and auxiliary circuit designs. Its black, red and yellow insulated cores help identify separate connections during assembly; the equipment wiring diagram, not insulation color alone, determines conductor function. Contact us with equipment drawings, length and quantity requirements for a project-specific review.

Compared with an unshielded cable, foil and copper shielding may reduce electromagnetic noise coupling when the complete assembly is correctly terminated and routed. Actual EMC performance depends on the noise frequency, shield coverage, connector design and grounding approach. The tinned copper strands support soldering and surface oxidation resistance, while the jacket provides insulation protection within its rated conditions.

The published available length range is 5 m to 5,000 m. Importers, equipment manufacturers and electrical wholesalers can provide requested cut or reel lengths, annual or project quantities, conductor mapping, packaging preferences and destination-market documentation needs for quotation confirmation.

Request 14/3 Shielded Wire Pricing

14 AWG 3-Conductor Cable Specifications

14 AWG 3 conductor electrical double shielded wire product view

14 Gauge 3 Conductor Wire

Rated Voltage 300V Number of Conductors 3 twisted conductors
Rated Temperature 80°C / 176°F Wire Size 14 AWG
Conductor Resistance 9.25 Ω/km at 20°C Conductor Material Tinned stranded copper
Insulation Resistance >10 MΩ/km at 20°C Foil Orientation One-side aluminum, aluminum facing outward
Electric Current 12A Insulation Material PVC (RoHS)
Material Structure PVC + tinned copper + aluminum Jacket Material PVC (RoHS)
Conductor Colors Black, red and yellow
Jacket Diameter 9.0 mm ± 0.3 mm
Available Length 5 m to 5,000 m

For correct cable selection, verify operating voltage, actual continuous current, circuit duty, total cable length, voltage drop, grouping, ambient conditions, cable entries and shielding termination. The 12A shown in the source specification is a product-listed figure, not permission to use the cable at 12A under every wiring method. Check the applicable electrical requirements before installation.

Insulation-resistance figure: The source table publishes >10 MΩ/km at 20°C. For approval testing, request the exact unit definition, sample length and method; the published notation should not be silently converted into a different measurement.

Request Technical Data for 14 AWG 3-Core Cable

14/3 Double-Shielded Cable Features

UL2464 14 AWG 3 core double shielded wire tinned copper structure

UL2464 Style Reference — Confirm Documentation Aluminum + Tinned-Copper Double Shielding Tinned Copper Core

Why Choose Our Wire

Shielded cable conductor and insulation structure

Oxidation-resistant tinned copper wire icon Low eccentricity shielded cable icon High conductivity tinned copper cable icon PVC insulation resistance icon
Oxidation Resistance Low Eccentricity High Conductivity Insulation Resistance

High Conductivity

At the same conductor material, length and temperature, 14 AWG has a larger nominal copper cross-section and generally lower resistance than 16 AWG, 18 AWG or 22 AWG. Tinning improves the conductor surface for soldering and oxidation resistance; it does not imply that tinned copper has higher intrinsic bulk conductivity than equally sized bare copper.

Advantage of Tinned Copper
Comparison Item Tinned copper conductorTinned Copper Bare pure copper conductorPure Copper Copper clad aluminum conductorCCA
Copper-Clad Aluminum
Easy to Solder Recommended conductor feature Standard conductor feature Standard conductor feature
Copper Conductor Properties Recommended conductor feature Recommended conductor feature Standard conductor feature
Anti-Oxidation Recommended conductor feature Standard conductor feature Standard conductor feature
Anti-Corrosion Recommended conductor feature Standard conductor feature Standard conductor feature
Durability by Application Recommended conductor feature Standard conductor feature Standard conductor feature

Tinned stranded copper supports reliable conductor terminations and resistance to surface oxidation. Electrical performance and service life still depend on wire size, equipment loading and environmental conditions.

Double Shielded Layer

Aluminum and tinned copper double shielded layer for 14 AWG 3 core cable

The cable incorporates aluminum foil shielding and a tinned-copper shielding layer surrounding its three insulated conductors. This arrangement can help limit electrical noise coupling in suitable machine-control and equipment wiring when the shield is terminated according to the overall EMC design.

In practical equipment wiring, the cable shield should be terminated according to the controller, VFD, motor or machine manufacturer's grounding and EMC instructions. The shield is used for interference control and should not be treated as a replacement for a required protective-earth conductor.

14/3 Shielded Cable Construction and Installation

Three insulated 14 AWG cores: This cable contains three conductors rather than three conductor pairs. The published core colors are black, red and yellow; none of those colors independently establishes a protective-earth or polarity assignment.

Two metallic shielding materials: Aluminum foil and tinned copper help manage induced interference. Shield bonding, cable routing, connector construction and the equipment EMC plan determine performance in practice. The shielding layer must not be used as a substitute for a required protective-earth conductor.

Jacket and mechanical fit: The PVC jacket is specified as 9.0 ± 0.3 mm outer diameter. Match it with appropriate cable glands, strain relief and routing space. Minimum bend radius, UV performance and continuous-flex cycle rating are not defined in the source information.

Discuss 14/3 Cable Construction and Shielding

Applications of 14 AWG 3-Core Shielded Cable

14 AWG 3 conductor shielded wire for transformer connections 14 AWG 3 conductor shielded wire for electronic instruments
Transformer Electronic Instrument
14 AWG 3 conductor shielded wire for electrical appliances 14 AWG 3 conductor shielded wire for motors and CNC control equipment
Electrical Appliance Motor

Potential applications include suitable CNC machine-control circuits, electrical panels, instrumentation interconnections, auxiliary motor controls, transformer-associated control wiring and electronic equipment. Selection must be confirmed against the actual wiring diagram, circuit current, voltage rating, local electrical requirements and installation environment; the presence of a shield does not establish universal suitability for all motors or VFD power outputs.

For OEM machinery, maintenance replacement and industrial distributors, compare the equipment wiring diagram with conductor count, insulation rating, cable diameter and shielding method. Do not assume this cable is approved for inverter-to-spindle main power, continuously moving drag chains or applications requiring a dedicated protective-earth conductor without separate supporting documentation.

14/3 vs 14/2, 14/4 and 16/3 Cable Selection

For replacement and new-equipment wiring, start by matching the number of insulated conductors, then verify conductor gauge, circuit current, voltage drop, operating temperature, shielding design and mechanical installation. The comparison below describes general construction differences; actual cable ratings remain model-specific.

Cable type Conductor arrangement Selection consideration
14/3 shielded cable Three 14 AWG insulated cores This product; three assigned circuit conductors
14/2 shielded cable Two 14 AWG insulated cores One fewer conductor; check the wiring diagram
14/4 shielded cable Four 14 AWG insulated cores One additional circuit conductor if needed
16/3 shielded cable Three 16 AWG insulated cores Smaller nominal copper cross-section; evaluate circuit resistance

Three conductors are not three pairs: A three-pair cable generally contains six insulated conductors. The published specification for this product lists three twisted conductors and does not declare individually shielded pairs, characteristic impedance or data-bus performance.

Compare 14 AWG Shielded Cable Configurations

Zhong Hua Jiang shielded electrical wire product range

Related Shielded Cable Options

Zhong Hua Jiang also offers other shielded electrical wire constructions and cable categories intended for different conductor counts and movement conditions. Compare cable dimensions, electrical limits and whether a dedicated continuous-flex chain cable is necessary before selecting a replacement.

Company Profile

Zhong Hua Jiang CNC spindle motor and electrical wire manufacturer

Electrical Shielded Wire Manufacturer

Zhong Hua Jiang manufacturing company profile

How We Started

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.

What Makes Us Proud

The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.

Why Choose Us

Zhong Hua Jiang quality assurance, patents and brand advantages
Quality Assurance
Product inspection and quality-control procedures before shipment.
Patents and Certifications
Long-term CNC manufacturing experience and patented spindle designs.
Additional Brand Value
Integrated product support for CNC machines, spindles, accessories and wiring.
Zhong Hua Jiang price, service and delivery advantages
Reasonable Price
Direct factory communication for specifications, quantities and custom lengths.
Full Time Service
Technical support for cable gauge, conductor count and application selection.
Fast and Reliable Delivery
Production coordination, shipment updates and export-order service.

Leading CNC Machine / CNC Spindle Motor Manufacturer Since 2000

Our Product Range

CNC Router Machines

CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.

CNC Spindle Motors

Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.

CNC Accessories

The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.

Electrical Wires

Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.

Stepper Motors

Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

OEM and Wholesale 14 AWG Shielded Cable Orders

To request a project quotation, specify 14 AWG / 3 conductors, cable lengths, total quantity, destination market, equipment application and any required core-color assignment, labeling, reel packaging or special termination. The published length range is 5–5,000 m; exact order options and feasibility are subject to supplier confirmation.

Industrial buyers should also define the required voltage and temperature limits, working current, cable routing and flexing duty, expected electromagnetic-noise environment, and the regulatory or acceptance documents needed for their equipment or resale market. Provide the machine or controller model when compatibility is critical.

Request OEM and Wholesale Cable Quotation

Product Certification

Zhong Hua Jiang shielded wire product certification document

For orders requiring UL AWM Style 2464 or RoHS documentation, request the current product-specific records, applicable marking, manufacturer information and test reports for the exact cable supplied. A style reference or a generic certification image does not establish that every cable configuration has a particular approval.

Customer Feedback

Customer feedback for Zhong Hua Jiang shielded electrical wire

Send Your 14/3 Wiring Requirements

FAQ

What is 14 AWG 3 conductor electrical double shielded wire used for?

It is used for three-core higher-current control, auxiliary power and low-voltage equipment wiring where EMI reduction is important. Typical applications include CNC machines, VFD-related control circuits, motor auxiliary wiring, electronic instruments, transformers, power-limited control systems, security wiring, lighting control, audio/control signal paths and monitoring circuits.

What does 14/3 shielded cable mean?

“14/3” means the cable contains three insulated 14 AWG conductors. In this product, the three conductors are twisted and protected by aluminum and tinned-copper shielding layers inside an overall PVC jacket.

What are the voltage, temperature and current ratings?

The listed rated voltage is 300V, the listed rated temperature is 80°C / 176°F and the listed current is 12A. Final suitability depends on circuit design, voltage drop, load type, installation environment, cable length, bundling and applicable standards.

How does double shielding improve EMI resistance?

The aluminum foil and tinned-copper shielding layers form conductive barriers around the insulated conductors. When terminated correctly, these layers help reduce interference from motors, VFDs, switching power supplies and other noise sources, improving stability in sensitive control or auxiliary-power wiring.

Should the cable shield be grounded at one end or both ends?

Shield termination depends on the equipment, frequency range, enclosure bonding and EMC design. Follow the CNC controller, VFD, motor or equipment manufacturer's wiring instructions. The cable shield should not replace a required protective-earth conductor.

What is the difference between 14/3 and 14/2 shielded wire?

Both products use 14 AWG conductors, but 14/3 provides three insulated cores while 14/2 provides two insulated cores. Choose 14/3 when the circuit needs an additional conductor for common, feedback, brake, signal reference, control return or three-wire device wiring.

Is 14 AWG 3 core shielded wire suitable for motor or VFD wiring?

It can be used for suitable motor auxiliary, feedback, brake, sensor or low-voltage control circuits when the electrical requirements match the cable rating. For main motor power, VFD output power or safety-critical wiring, confirm cable type, insulation rating, shielding method and applicable standards before use.

Is this cable suitable for drag-chain or continuous-motion use?

Standard flexible shielded cable may be suitable for fixed or occasional-flex installations. Continuous high-cycle motion generally requires a cable specifically designed for drag chains. Provide bend radius, travel distance, speed and cycle frequency so the proper cable type can be confirmed.

Can the length and packaging be customized?

Yes. The available length range is 5 m to 5,000 m. Buyers can provide the required roll length, total quantity, packing preference, labeling needs, application and destination market for quotation confirmation.

What information should I provide when requesting a quote?

Provide the cable gauge, conductor count, required length, estimated quantity, voltage, current, equipment model, installation movement, conductor-color requirement, termination method and delivery destination. These details help confirm the right cable and produce an accurate quotation.

How does Zhong Hua Jiang control product quality?

Zhong Hua Jiang describes quality-control checks before dispatch. Buyers can request a current cable datasheet, inspection requirements, material details and test or conformity documents appropriate to the purchase specification before approving a production order.

Are three 14 AWG conductors the same as three twisted pairs?

No. The published product contains three individually insulated 14 AWG cores, not three pairs. A three-pair construction normally contains six conductors and may have additional pair-specific properties not specified for this model.

What is the outer diameter and core color arrangement?

The published outer jacket diameter is 9.0 ± 0.3 mm. Its conductor colors are black, red and yellow. Confirm the function of each core using the equipment wiring diagram rather than color assumptions.

How is 14 AWG 3-core cable different from 16 AWG 3-core cable?

For otherwise equivalent copper constructions, 14 AWG has a larger nominal cross-section and lower conductor resistance than 16 AWG. The proper choice depends on current, voltage drop, routing size, thermal conditions and the exact cable specification.

Does the source-listed 12A figure determine the installation ampacity?

No. The product information lists 12A, but permissible continuous current depends on equipment duty, installation method, ambient temperature, cable grouping, permissible conductor temperature and local wiring requirements.

Can the shield replace a protective-earth conductor?

No. Foil and copper shielding help manage electromagnetic interference; they must not be assumed to provide the required protective-earth path or replace other protective bonding arrangements.

Can 14/3 shielded wire be used for main VFD motor output?

Not without model-specific engineering approval. VFD output cables may require additional insulation, symmetry, conductor and shield properties. Follow the drive and motor manufacturer cable guidance for the final installation.

Is this cable designed for continuous drag-chain motion?

The published data does not establish a dynamic bend radius, flex-cycle rating or cable-carrier qualification. Select a dedicated motion cable when the application involves frequent or continuous flexing.

What does UL AWM Style 2464 indicate?

It is a reference to an appliance-wiring material style. The style reference alone does not verify a specific cable manufacturer or product certification. Ask for current documentation and matching marking for the supplied model.

Are RoHS documents available for the insulation and jacket?

The published specification describes both PVC insulation and jacket as RoHS. Buyers who need documentary evidence should request a current product-specific declaration and supporting test documentation.

What is the listed conductor resistance?

The published value is 9.25 Ω/km at 20°C. Circuit design should account for total conductor path length, terminations, operating temperature and acceptable voltage drop.

Which test data should OEM buyers verify before production?

Confirm the cable datasheet, insulation-resistance test method and units, shielding construction, mechanical tolerances, required conformity documents and any application-specific electrical performance values.

What details help a distributor obtain an accurate wholesale quote?

Provide the 14/3 cable specification, reel or cut lengths, purchase volume, destination country, equipment application and any required labeling, packing or regulatory documentation.

Contact Zhong Hua Jiang for Pricing and Custom Lengths

Previous: 
Next: 

Product Category

Apply Our Best Quotation

Global Recruitment of Authorised Agents!

Join us as an exclusive distributor of CNC Router Machines and CNC Spindle Motors. As a professional manufacturer, we provide high-performance machines, attractive profit margins, technical training, and full marketing support. Build a strong partnership with us and expand your market with confidence.

Products

Quick Links

Contact Us

   zhonghuajiang@huajiang.cn
  +86-13915011877
   No.379-2, Hengyu Road, Henglin town, Wujin District, Changzhou, Jiangsu, China
© COPYRIGHT 2025 CHANGZHOU HUAJIANG ELECTRICAL CO.,LTD ALL RIGHTS RESERVED.