22AWG 3 Core
Hantechn
22AWG
5m-5000m
3
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
40.1Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22AWG 3-conductor shielded drag chain cable is designed for compact signal and control wiring in CNC machines, cable carriers, industrial automation systems and moving equipment. Three twisted tinned stranded copper conductors, PVC insulation, an overall shielding layer and a flexible jacket support organized connections where electrical interference and frequent movement must be considered.
The published 22/3 cable specification lists a 300V voltage rating, an 80°C (176°F) temperature rating and a 5.2 ± 0.3mm jacket diameter. It is intended for compatible sensor, switch and control circuits after current, voltage drop, connector size and cable-carrier movement are checked.
Request 22AWG Three-Core Cable Pricing
Three insulated 22AWG stranded tinned-copper conductors are twisted together under an overall shield. The supplied specification identifies PVC as both insulation and jacket material and lists cotton rope and cotton paper within the cable construction. The conductor arrangement is suitable for selected three-wire control connections when an approved wiring diagram is followed.
For engineering approval, request a cross-sectional drawing, shielding details, conductor resistance report and dynamic bend-radius data for this specific 22AWG three-core model. Confirm that the cable, connectors and machine design meet the installation environment before making a bulk purchase.

This 22AWG three-core shielded drag-chain wire is offered to CNC equipment builders, automation integrators, maintenance teams, importers and electrical cable distributors who need three insulated conductors for compatible low-current signal and control wiring.
An overall cable shield can help reduce unwanted electromagnetic coupling near motor drives, control cabinets and switching devices when installed and terminated correctly. Effective screening also depends on cable routing and bonding. The shield is not an extra insulated conductor or a substitute for required protective earth.
Send your required 22AWG × 3 configuration, cable length, quantity, equipment application, control voltage and current, bend-radius requirements, termination details and intended delivery destination to discuss a suitable quotation.

| Rated Voltage: | 300V | Number of Conductors: | 3 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 22AWG |
| Conductor Resistance: | 40.1 Ω/km at 20°C (as published; verify test report) | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green | ||
| Jacket Dia(mm): | 5.2 ± 0.3 | ||
The supplied technical table lists 40.1 Ω/km conductor resistance at 20°C. Confirm the reported test method and actual product measurement before relying on this figure for voltage-drop calculations or an engineering specification.
For insulation resistance, dielectric withstand, RoHS or UL-related claims, request the current documentation and measurement conditions that specifically identify the ordered cable model.
Request a 22AWG 3-Core Datasheet

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The cable is marketed for moving drag-chain installations. Promotional material mentions 15 million bending cycles, but actual mechanical life depends on testing and operating conditions; obtain the relevant test report before using a cycle count as a design limit.
Check the cable manufacturer’s minimum dynamic bend radius, drag-chain travel distance, speed, acceleration, installation clearance and strain relief. No single bend-radius value can be reliably inferred from the outside diameter alone.
The listed 5.2 ± 0.3mm cable jacket diameter is useful when selecting compact cable carriers, glands and connector entries. Verify the actual cable dimensions and moving-chain requirements against the approved product drawing.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned stranded copper combines electrical conductivity with practical solder termination and resistance to oxidation at exposed strand surfaces.
Cable service life depends on conductor stranding, jacket construction, bend radius, carrier travel and installation conditions.
Use the verified conductor resistance and total run length to assess voltage drop and signal integrity for the actual circuit.

The cable shield can help reduce unwanted electromagnetic interference from adjacent electrical equipment when correctly installed.
For sensitive control and sensor circuits, check the machine maker’s instructions for shield termination, separation from motor-output cables and electrical bonding.
A cable shield does not replace a dedicated protective-earth conductor. Follow the machine’s approved safety and grounding design.
The product marketing material refers to a 15-million-cycle bending result, but no detailed dynamic bend radius, travel speed, cycle-test setup or acceptance criteria are supplied. Assess cable-carrier suitability using a specific test report and your equipment movement requirements.
Discuss Your Cable Carrier Requirements

A flexible three-conductor option for selected shielded connections within compact cable carriers.
Typical evaluation areas include CNC sensor wiring, position and limit switches, three-wire transducer connections and compatible industrial control assemblies.
This 22AWG three-conductor shielded drag-chain cable may be used for appropriate three-wire signal or control arrangements in CNC routers, automation machinery and moving sensor installations. Verify conductor assignment and circuit current; the three-core construction does not by itself establish compatibility with a specific bus protocol, VFD output or servo power supply.
For an accurate OEM quotation, provide the required run length, order volume, approved wiring diagram, required current and voltage, cable-carrier travel and dynamic bend radius, connector specification, local environment and packaging expectations.
Use a three-conductor shielded cable when the approved wiring diagram calls for three insulated cores plus an overall shield. Review the required circuit current, voltage, sensor or control interface, cable run length, noise environment and motion profile. The shield is not a fourth insulated core and must not be treated as protective earth.
Conductor count should match the equipment wiring diagram. A two-core cable supports two insulated circuit connections; three-core cable permits three; a four-core cable provides an additional insulated path. The correct choice also depends on conductor gauge, rated current and the equipment-specific pinout.
| Cable option | Insulated conductors | Selection consideration |
| 22AWG × 2 | 2 | Two-wire sensor or switch circuits when compatible |
| 22AWG × 3 | 3 | Three-wire control, sensor or signal arrangements when compatible |
| 22AWG × 4 | 4 | Four separate insulated connections if required by the wiring diagram |
The listed outside diameter is 5.2 ± 0.3mm. Confirm gland fit, carrier clearance, separation from other cables, the permitted dynamic bend radius and the actual movement profile before approving an installation.
The product lists Black, White and “Yellow and Green” for three conductors. Check the manufacturer’s drawing to establish whether the third core is yellow/green striped, then identify each conductor using the machine wiring diagram. For the cable shield, follow the controller manufacturer’s termination and bonding instructions.
The supplier table publishes 40.1 Ω/km at 20°C. For a long sensor run or a circuit sensitive to voltage loss, request the current measured value for this exact cable and calculate voltage drop using the full circuit length and operating current.
Send Your 22AWG Three-Wire Cable Specification
Explore the shielded drag-chain and double-shielded wire ranges from Zhong Hua Jiang. Compare conductor count, wire gauge, moving versus fixed installation and cable dimensions before selecting an equivalent wiring product.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company offers CNC router machine configurations such as 3018, 3020, 3040 and 6090 for engraving, cutting and related machining work.
The product range includes air-cooled and water-cooled spindle motors for different CNC machine power and cooling requirements.
CNC accessories include limit switches, Z probes, emergency-stop buttons and related machine-control parts.
The electrical wire range includes shielded drag-chain cables for moving applications and other shielded wire constructions for equipment wiring.
Stepper motors are used for controlled positioning in compatible CNC and automation systems.
For a project quotation, provide the 22AWG three-core requirement, requested reel or cut length, forecast quantity, wiring application, operating voltage and current, motion requirements, connector or termination details, packaging preferences and destination.
Technical buyers may request the actual 22AWG × 3 cable drawing, shielding construction, conductor-resistance test report, applicable compliance records and the flex-test setup. Confirm document applicability by product code.
Request OEM and Wholesale Pricing

The documents displayed above may represent multiple CNC or cable products. Request the current documentation matching the exact 22AWG three-core cable for any application-specific approval requirement.

The cable is intended for suitable 22AWG × 3 low-current control or signal connections in CNC machinery, sensor assemblies and cable drag chains where an overall shield can help manage electrical interference.
Shielding helps limit coupled electrical noise near drives, switching devices and power cables when installed correctly. Route and terminate the shield according to the controller and equipment manufacturers’ requirements.
The product is presented for cable-carrier movement. However, minimum dynamic bend radius, working speed, stroke length and flex-test conditions are not stated in the supplied technical table. Request these data for the specific ordered cable.
The published specification lists three twisted 22AWG tinned-copper conductors, 300V and 80°C (176°F) ratings, PVC insulation and jacket, and a 5.2 ± 0.3mm outside diameter. It lists conductor resistance as 40.1 Ω/km at 20°C; confirm this figure with a model-specific measurement report.
The source lists Black, White, and “Yellow and Green” as conductor colors. Because the product has three conductors, confirm whether Yellow/Green refers to a single striped conductor and verify its assigned function against the formal cable drawing. Never assume protective-earth status from marketing text alone.
Tinned stranded copper provides conductivity, solderability and useful resistance to oxidation at exposed surfaces. Individual strands contribute to flexibility in an appropriately designed moving-cable assembly.
Discuss cable length, conductor identification, jacket requirements, packaging and other project-specific features with Zhong Hua Jiang. Final custom arrangements are subject to technical confirmation.
For a wholesale quotation, specify 22AWG × 3, required length, estimated quantity, control voltage and current, cable carrier dimensions and movement, connectors, destination and documentation requirements.
Huajiang began producing CNC spindle motors in 2000, expanding into VFDs, CNC router machines, accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 for international markets.
It has three insulated conductors of 22AWG size within a shielded cable assembly. The supplied construction uses twisted tinned stranded copper conductors, PVC insulation and PVC jacket.
The published outside diameter is 5.2 ± 0.3mm. Check the final cable drawing when sizing a cable gland, drag-chain compartment or connector.
The product table specifies 300V and 80°C (176°F). These values do not establish allowable continuous current or compliance with every machine installation standard.
The published table lists 40.1 Ω/km at 20°C. Request a cable-specific test report to verify that measurement, particularly for voltage-drop-sensitive circuits.
The description says Black, White, Yellow and Green. Confirm whether the final item is black, white and one yellow/green striped core; request a formal drawing for conductor assignment.
No. Determine the conductor function from the certified cable construction and the machine wiring diagram. Do not assume a safety-earth function based only on a marketing color description.
A three-core cable provides three insulated conductors rather than two. Select the correct number from the sensor, controller or equipment terminal diagram.
It is presented for dynamic cable carriers. Confirm the manufacturer-approved bending radius, carrier travel and cable movement conditions for the exact model.
The supplied table does not specify a numeric value. Ask for the approved dynamic bend radius and installation instructions for this cable.
No universal guarantee follows from a cycle figure alone. Request a flex-test report specifying bend radius, speed, stroke, load and test method.
The tin coating can help limit oxidation at exposed surfaces and support solder termination. The multi-strand construction also contributes to cable flexibility.
An appropriately bonded shield can reduce coupled electromagnetic noise. The result also depends on separation from motor power cables, routing and shield termination.
No. Shielding and protective earthing have different functions. Provide any required protective-earth connection according to the approved equipment design.
Do not assume so. Spindle and VFD output cables must be selected according to the drive and motor specifications, including conductor size, current, grounding and applicable installation requirements.
The product table does not supply characteristic impedance or protocol-specific electrical data. Check the protocol requirements and obtain the construction drawing before selecting the cable.
The provided description identifies PVC but does not specify oil, UV or weather resistance. Request appropriate supporting data when those environmental conditions apply.
The product images and table refer to UL and RoHS. Request current model-specific records or declarations before making compliance claims.
Send the 22AWG × 3 configuration, required lengths, quantity, destination, machine application, electrical requirements, motion conditions and required documents.
These arrangements can be discussed for OEM orders. Provide your drawings, length and quantity requirements for a feasibility and quotation review.
Quick Links