Zhong Hua Jiang 22 AWG 6-Conductor Double-Shielded Cable is a six-core cable for compatible CNC controls, automation equipment, electronic instruments and low-voltage signal connections. The product combines six twisted, individually insulated tinned stranded-copper conductors, an aluminum shielding layer and a tinned-copper shielding layer beneath a PVC outer jacket. This construction is intended for equipment builders, integrators and distributors seeking compact multi-core wiring with interference protection.
The listed electrical and mechanical specifications include a 300V voltage rating, 80°C (176°F) temperature rating, 59.4 Ω/km conductor resistance at 20°C and a 6.5 ± 0.15 mm jacket outside diameter. Six insulated cores are identified as black, red, yellow, white, green and orange. The suitability of this construction depends on the circuit, conductor functions, cable routing, shielding termination, current and installation requirements.

This 22/6 six-core shielded cable is designed for applications that need six individually insulated 22 AWG conductors in a common PVC jacket. Typical evaluation scenarios include control-panel wiring, multi-signal sensor connections, equipment interfaces and low-power monitoring circuits. The six conductor colors assist with wiring identification, but the electrical function of each conductor must follow the equipment schematic.
Compared with a similar unshielded multi-core cable, the aluminum and tinned-copper shielding layers help reduce interference coupling when correctly bonded and terminated. Tin-plated stranded copper supports solderable terminations, flexibility during installation and oxidation resistance. Actual EMI performance depends on the shielding construction, cable routing, enclosure bonding and connector termination.
For OEM assembly, equipment maintenance, system integration and wholesale supply, provide the required cut length or reel length, quantity, intended application, mechanical duty, relevant compliance documents and delivery market. Nonstandard lengths, labeling or packaging should be confirmed with the sales team before ordering.
Request 22/6 Shielded Wire Pricing
Request Wholesale 22/6 Shielded Cable Pricing

| Rated Voltage | 300V | Number of Conductors | 6 twisted conductors |
| Rated Temperature | 80°C / 176°F | Wire Size | 22 AWG |
| Conductor Resistance | 59.4 Ω/km at 20°C | Conductor Material | Tinned stranded copper |
| Insulation Resistance | 10 MΩ/km at 20°C | Foil Orientation | One-side aluminum, aluminum facing outward |
| Dielectric Test | 2000 VAC/min | Insulation Material | PVC (RoHS) |
| Material Structure | PVC + tinned copper + aluminum | Jacket Material | PVC (RoHS) |
| Conductor Colors | Black, red, yellow, white, green and orange | ||
| Jacket Diameter | 6.5 ± 0.15 mm | ||
| Available Length | 5 m to 5,000 m | ||
Request 22 AWG 6-Core Cable Data and Pricing
Technical interpretation: The published 10 MΩ/km at 20°C insulation-resistance entry and 2000 VAC/min dielectric-test entry should be supported by the manufacturer’s measurement method, test duration and unit definitions. Confirm the exact PVC material declaration and any model-specific regulatory records required for your destination market.
For accurate selection, confirm the required cable length, conductor assignment, signal type, voltage, current, bend requirement, shielding termination and equipment electrical specifications before ordering. For continuously moving cable-carrier applications, verify whether a dedicated shielded chain cable is required.

| AWM Style 2464 Reference — Verify Exact Product Records | Aluminum + Tinned-Copper Double Shielding | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistance |
The six 22 AWG conductors are specified as tinned stranded copper, with published conductor resistance of 59.4 Ω/km at 20°C. Tinned surfaces support soldering and oxidation resistance; the copper conductor provides electrical conductivity. Actual current capacity and voltage drop depend on cable length, ambient temperature, conductor grouping and circuit requirements.
| Advantage of Tinned Copper | |||
| Comparison Item | Tinned Copper | Pure Copper | CCACopper-Clad Aluminum |
| Easy to Solder | |||
| Better Conductivity | |||
| Anti-Oxidation | |||
| Anti-Corrosion | |||
| Sturdy and Durable | |||
The material-comparison illustrations are general examples rather than verified comparative test results for this cable. Bare copper is also solderable; for engineering decisions, use measured conductor resistance, cross-sectional area, termination requirements and the relevant environmental conditions.
Tinned stranded copper supports good conductivity, reliable termination and improved surface oxidation resistance.

An aluminum shielding layer and a tinned-copper shielding layer surround the insulated conductors. Used with suitable routing and terminations, they help reduce electromagnetic coupling from drives, motors, relays and other equipment. Shielding effectiveness is influenced by continuity, coverage, interference frequencies and installation details.
Follow the applicable controller, VFD, machine or instrumentation manufacturer’s wiring and EMC instructions when connecting the shield. Bonding at one end or both ends depends on the system design; the shielding layer must not be used as a substitute for a required protective-earth conductor.
Discuss Shielding and Cable Requirements
![]() | ![]() |
| Transformer | Electronic Instrument |
![]() | ![]() |
| Electrical Appliance | Motor |
This six-core cable may be evaluated for suitable CNC controller interfaces, electronic instruments, sensor assemblies, low-voltage automation controls, equipment monitoring and other wiring systems that require six insulated conductors under one shielded jacket. For encoder feedback, RS-232, RS-485 or other specified communication interfaces, verify the number of dedicated pairs, pair twist, characteristic impedance, signal requirements and maximum cable run before selecting a particular cable.
The cable is not automatically suitable as a VFD-to-motor power cable or for continuous high-cycle drag-chain motion. A specific motor cable, communication cable or high-flex chain cable may be required, depending on the electrical interface and machine movement. Share the circuit details and installation duty with Zhong Hua Jiang when requesting a compatible configuration.
Check Cable Suitability for Your Equipment
For dependable sourcing, match the number of cores and conductor functions to the equipment wiring diagram, then confirm electrical ratings, cable dimensions, shielding and movement requirements. Core count alone does not establish suitability for a given communication protocol or powered device.
| Selection Point | What to Confirm |
|---|---|
| Conductor assignment | Six insulated cores: black, red, yellow, white, green and orange; assign functions using the wiring schematic. |
| Electrical ratings | 300V, 80°C, published conductor resistance 59.4 Ω/km at 20°C; verify load current and voltage drop. |
| Shield construction | Aluminum plus tinned-copper shielding; confirm shield termination and enclosure bonding. |
| Cable entry and movement | Overall jacket diameter 6.5 ± 0.15 mm; check glands, bend conditions and moving-axis requirements. |
| Bulk order information | Cable length per cut or reel, total quantity, packaging, destination country and required documentation. |
Send 22/6 Cable Requirements for a Quote
A 22/6 cable contains six insulated 22 AWG conductors; a 22/5 cable has five. Choose the conductor count based on actual control signals, returns and auxiliary connections. Do not treat a six-core cable as three independently twisted pairs unless the manufacturer confirms the internal pair arrangement.
Compared with 22 AWG, 20 AWG has a larger nominal conductor cross-section and generally lower resistance over equivalent cable lengths and materials. Selecting the larger wire size may reduce voltage drop for appropriate current-carrying circuits, but the correct choice also depends on cable diameter, flexibility, connectors, communication requirements and equipment specifications.
Compare Shielded Cable Sizes and Core Counts
Alongside this 22 AWG six-core double-shielded cable, Zhong Hua Jiang lists other conductor sizes, core counts and cable structures for machine-control systems, electrical equipment and moving-cable installations. Compare the required electrical ratings and mechanical duty before choosing a model.

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.
The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.
![]() | ||
| Quality Assurance Product inspection and quality-control procedures before shipment. | Patents and Certifications Long-term CNC manufacturing experience and patented spindle designs. | Additional Brand Value Integrated product support for CNC machines, spindles, accessories and wiring. |
![]() | ||
| Reasonable Price Direct factory communication for specifications, quantities and custom lengths. | Full Time Service Technical support for cable gauge, conductor count and application selection. | Fast and Reliable Delivery Production coordination, shipment updates and export-order service. |
CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.
Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.
The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.
Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.
Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

Cable specifications, material declarations and third-party certification claims must be checked for the exact model. An AWM Style 2464 reference identifies a wiring style, but its presence in a description does not establish that a particular cable has an applicable UL recognition. Ask for the current file number or certificate, relevant markings, RoHS declaration and any testing records required by your market and equipment application.
Request Model-Specific Cable Documents

It is used for six-core signal, control and low-voltage equipment wiring where EMI reduction is important. Typical applications include CNC machines, VFD spindle control, stepper motors, automation panels, electronic instruments, sensors, electrical appliances, transformers, 3D printers, RS-232-style control wiring, audio or control signal paths and monitoring systems.
“22/6” means the cable contains six insulated 22 AWG conductors. In this product, the six conductors are twisted and protected by aluminum and tinned-copper shielding layers inside an overall PVC jacket.
The listed rated voltage is 300V and the listed rated temperature is 80°C / 176°F. Final suitability depends on circuit design, load, installation environment, applicable standards and machine-manufacturer requirements.
The aluminum foil and tinned-copper shielding layers form conductive barriers around the insulated conductors. When terminated correctly, these layers help reduce interference from motors, VFDs, power supplies and other noise sources, improving signal stability in sensitive equipment wiring.
Shield termination depends on the equipment, frequency range, enclosure bonding and EMC design. Follow the CNC controller, VFD, motor or equipment manufacturer's wiring instructions. The cable shield should not replace a required protective-earth conductor.
Both products use 22 AWG conductors, but 22/6 provides six insulated cores while 22/5 provides five insulated cores. Choose 22/6 when the circuit requires an additional signal, feedback, common, enable or control conductor in the same shielded cable.
It is mainly used for low-voltage control, signal and light-duty circuits. The final current capacity depends on the installation, temperature, cable length, bundling and applicable electrical standards. Verify the circuit current before using 22 AWG cable for power transmission.
Standard flexible shielded cable may be suitable for fixed or occasional-flex installations. Continuous high-cycle motion generally requires a cable specifically designed for drag chains. Provide bend radius, travel distance, speed and cycle frequency so the proper cable type can be confirmed.
Yes. The available length range is 5 m to 5,000 m. Buyers can provide the required roll length, total quantity, packing preference, labeling needs, application and destination market for quotation confirmation.
Provide the cable gauge, conductor count, required length, estimated quantity, voltage, current, equipment model, installation movement, conductor-color requirement, termination method and delivery destination. These details help confirm the right cable and produce an accurate quotation.
For an OEM or wholesale order, request the current product-specific data sheet, available inspection reports and compliance records. Confirm the acceptance criteria and supporting test documentation for the exact cable configuration.
Not necessarily. The published construction lists six twisted conductors, but does not specify three individually twisted pairs. If your communication protocol requires dedicated differential pairs, ask for a conductor-lay diagram and the relevant impedance specification.
It may be considered only when the encoder manufacturer’s wiring requirements match the conductor count, pair arrangement, shield, capacitance, voltage and cable motion. Some encoders require dedicated twisted differential pairs or special high-flex cable; do not substitute based on core count alone.
RS-485 links often specify controlled-impedance twisted-pair cable. This product description does not establish a characteristic impedance or individually twisted pair design. Verify those requirements before using it for RS-485 or other differential communication.
Both use 22 AWG insulated conductors; 22/6 has six cores, while 22/5 has five. Choose the extra conductor only when it is required by the approved equipment circuit or wiring diagram.
With comparable materials and design, 20 AWG provides a larger conductor area and generally lower resistance than 22 AWG. Select according to allowable voltage drop, current, cable length, connector size and required flexibility.
The product lists a green insulated core, but its color alone does not establish whether it is approved for protective earth in a given installation. Follow the equipment wiring diagram and the relevant electrical code. The cable shield must not replace protective earth.
The listed overall jacket diameter is 6.5 ± 0.15 mm. Check the gland’s permitted sealing range and the connector’s strain-relief dimensions against that tolerance before placing an order.
Sensitive control and signal cables may require separation from motor-power and VFD output circuits to reduce coupling. Follow the machine manufacturer’s EMC and routing instructions and use correctly terminated shielding.
Only if the equipment designer confirms suitable current, voltage drop, temperature and cable construction. The listed 300V rating does not establish permissible current; many motor and high-flex circuits need a dedicated cable type.
A reference to UL AWM Style 2464 does not by itself prove recognition of this exact cable. Request the corresponding manufacturer file, product identification and recognized-component documentation, then confirm the intended use and markings.
The published data lists 10 MΩ/km at 20°C and 2000 VAC/min. Ask for the measurement method, test duration and units before treating these numbers as contractual acceptance criteria.
Minimum quantity, available packaging and production lead time should be confirmed for the requested configuration. Provide the cut or reel length, estimated order volume, required documents and delivery country when requesting a quotation.
Ask for the current model-specific data sheet, applicable material compliance declarations, available quality-test documents and any market-specific certification records. Confirm that each document applies to the exact cable being purchased.