20AWG 2 Core
Zhong Hua Jiang
20AWG
2
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
36.7Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|
Zhong Hua Jiang 20 AWG 2-core double-shielded electrical wire features tinned stranded copper conductors, PVC insulation and jacket, plus aluminum foil and tinned-copper shielding. It is intended for compatible signal and control circuits in CNC systems, industrial equipment and electronic instrumentation.

The Zhong Hua Jiang 20AWG 2-conductor double-shielded cable combines two twisted, tinned stranded copper conductors with PVC insulation, an outer PVC jacket, aluminum foil and a tinned-copper shielding layer. It is intended for equipment builders and industrial buyers evaluating compact low-voltage control and signal wiring near electrically noisy machinery.

With two separately insulated cores in a single 5.1 ± 0.15 mm jacket, this 20/2 cable can simplify routing for compatible two-wire sensor, trigger and controller connections. The published 300 V and 80°C ratings help buyers assess the design, but allowable current and installation suitability must be assessed separately.
The conductors are identified as black and red in the supplied specification. Color alone does not determine whether a core is positive, negative, signal or return: follow the equipment schematic and applicable wiring conventions. The tinned copper construction is useful where consistent termination and solderability are important.
OEM machine manufacturers, control-panel integrators, distributors and maintenance buyers can send a target length, quantity, connector specification and electrical application for a configuration review. Shield termination, routing and the final cable assembly should be confirmed for each equipment design.
Review the published dimensions and electrical ratings below when assessing this 20/2 control cable for equipment integration. The test methods and certification documents for a specific production batch should be confirmed before specifying the product in an approved bill of materials.

20 AWG 2-Conductor Double-Shielded Cable
| Rated Voltage: | 300V | Number of Conductors: | 2 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 20AWG |
| Conductor Resistance: | 36.7Ω/KM at 20°C | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM at 20°C | One Side Aluminum (AL Facing Outside) | |
| Dielectric Test: | 2000AC V/min | Insulation Material: | PVC (RoHS) |
| Material: | PVC + Tinned Copper + Aluminum | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black & Red | ||
| Jacket Dia(mm): | 5.1±0.15mm | ||
The published specifications list a conductor resistance of 36.7 Ω/km at 20°C, insulation resistance of 10 MΩ/km at 20°C, and a dielectric-test notation of 2000 AC V/min. Buyers needing formal acceptance criteria should request the test conditions, units and the corresponding technical sheet.
A two-core 20AWG cable is different from a multi-core cable or a dedicated drag-chain cable. Choose the number of conductors according to your circuit, and determine whether repeated motion, cable carrier installation or higher current requires a different product. Shield coverage alone does not establish dynamic-flex life.
Request the 20AWG 2-Core Data Sheet

| UL Documents: Verify for Exact Cable | Double Shielded | Tinned Copper Core |
Verify any certification statement against documentation and labeling for the exact cable variant being ordered.

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |
Tinned stranded copper offers good conductivity, solderability and improved surface resistance to oxidation. Copper-clad aluminum (CCA) has different conductivity characteristics, while untinned copper can also perform well when correctly sized and terminated. Assess wire selection against the actual environment, termination process and electrical requirements.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA (Copper Clad Aluminum) | |
| Easy to Solder | ![]() | ![]() | ![]() |
| Better Conductivity | ![]() | ![]() | ![]() |
| Anti-oxidation | ![]() | ![]() | ![]() |
| Anti-corrosion | ![]() | ![]() | ![]() |
| Sturdy and Durable | ![]() | ![]() | ![]() |
Tinned Copper Conductors
Tin Plating Helps Limit Surface Oxidation
Designed for Convenient Soldered Terminations

The described construction uses aluminum foil plus a tinned-copper shielding layer around the insulated conductors. Together, these layers help limit electromagnetic coupling in signal and control cables when installed and terminated correctly.
Shield effectiveness depends on grounding strategy, shield coverage, terminations and physical separation from high-noise power wiring. Keep cable routing and connection requirements aligned with the equipment manufacturer’s recommendations.
A cable shield is intended primarily for electromagnetic compatibility and must not be treated as a substitute for a dedicated protective-earth conductor. Protective grounding and fault protection must be designed to applicable electrical standards.
![]() | ![]() |
| Transformer | Electronic Instrument |
![]() | ![]() |
| Electrical Appliance | Motor |
Discuss Bulk Orders and Cable Specifications
Typical application areas include CNC controller I/O, compatible sensor circuits, electronic instruments and machine control panels. The nearby transformers, motors and variable-frequency drives shown in the application illustrations are sources of potential electrical noise; they do not imply that this 20AWG two-core cable is rated for every motor supply circuit.
For industrial inquiries, share a circuit schematic or signal type together with rated voltage, expected current, cable routing conditions and desired quantity. This helps identify whether the 20AWG two-core shielded construction fits the intended use or whether a different cable category is more appropriate.
Check Cable Suitability for Your Project
Zhong Hua Jiang also presents shielded chain cable and other double-shielded cable categories. Compare the conductor count, AWG size, outer diameter, required flexibility and shielding structure before choosing a replacement or OEM cable.

Huajiang was founded in 2000 with CNC spindle motor products and later expanded its catalog to variable-frequency drives, CNC equipment, accessories and electrical wiring products.
The Zhong Hua Jiang brand was established in 2018. The company supplies CNC-related products and electrical accessories for overseas customers and equipment projects.
The company reports Patent No. 200730184245.5 for its air-cooled spindle motor range. Cable-specific compliance documents should be requested separately.
The company reports over 20 years of experience in CNC spindle motors and related equipment, with export activity in international markets including the United States and Germany.
![]() | ||
| Quality Assurance Product specifications for review Strict quality control | Patents and Certifications Company patents for air-cooled spindle motor designs | Additional Brand Value Established CNC product range for machine builders |
![]() | ||
| Reasonable Price Direct factory sales Pricing per quoted specification | Full Time Service Professional technical support Contact the sales team for support | Delivery Arrangements Lead time confirmed with order Shipping details per quotation |
The product range includes CNC router machines such as the 3018, 3020, 3040 and 6090 series for engraving and machining applications.
Air-cooled and water-cooled spindle motors are available in the company’s broader CNC product range. Match spindle power, voltage, cooling and speed control to the machine design.
Related CNC accessories include limit switches, Z probes and emergency-stop components for machine control and integration.
The electrical cable portfolio includes double-shielded signal cables and shielded chain cables for different routing and interference-control requirements.
Stepper motors are also part of the Zhong Hua Jiang range for CNC motion-control systems.
Compliance and certification materials shown below relate to the supplier’s product documentation. Confirm the exact cable model, applicable UL file or marking, and any RoHS declaration or test record with the sales team before making a compliance decision.

Customer feedback is presented below. For technical procurement, request current product specifications and relevant test documentation alongside commercial references.

For repeat purchases, send a drawing or cable specification with the intended circuit. Dimensions, shielding terminations, certifications and cut lengths should be confirmed against the final production variant.
| Purchase Detail | What to Specify |
| Electrical circuit | Signal type, system voltage, expected current and wiring schematic |
| Cable construction | 20AWG × 2 cores, foil and copper shield, PVC construction |
| Installation | Required length, routing, movement, environment and shield termination |
| Commercial requirements | Estimated order volume, packaging and supporting technical documents |
It is used for two-wire signal and control circuits in CNC equipment, instrumentation, electronic devices, sensors and machine control cabinets. The circuit designer must verify electrical ratings, installation conditions and conductor current requirements.
20 AWG 2 conductor double shielded wire is commonly used for low-voltage signal, power, sensor, controller, and equipment wiring where EMI protection and a compact two-core structure are required. It is suitable for CNC machines, electrical appliances, motors, transformers, electronic instruments, and control systems.
It indicates two separately insulated 20 AWG conductors within one jacket. The standard color arrangement shown is red and black; actual polarity and function must follow the equipment wiring diagram.
2 conductor means the cable contains two insulated conductors, usually used as positive and negative wires, signal and ground wires, or two-core control wiring. This product uses black and red conductor colors for easier polarity and circuit identification.
The aluminum foil and tinned-copper shielding help limit the coupling of electromagnetic noise into low-level signals. The level of protection also depends on cable routing, shield continuity and correct termination.
Double shielded wire adds aluminum foil and tinned copper shielding around the conductors. This helps reduce electromagnetic interference, supports more stable signal transmission, and improves wiring reliability near motors, VFDs, CNC controllers, switching power supplies, and other noise-generating equipment.
It may be suitable for compatible low-voltage control and sensing circuits near CNC equipment. It should not automatically be selected as a VFD-to-spindle motor power cable or protective earth conductor; assess the motor current, voltage, shielding, cable type and local electrical rules.
Yes. This 20AWG 2 core double shielded wire is suitable for CNC machine wiring, spindle-related auxiliary wiring, control circuits, sensors, switches, and low-voltage connections where flexible routing and EMI resistance are important.
The published technical data lists 300 V, 80°C (176°F) and a jacket diameter of 5.1 ± 0.15 mm. It also lists two twisted 20 AWG tinned stranded copper conductors with PVC insulation and jacket.
The main specifications include 20AWG size, 2 twisted conductors, 300V rated voltage, 80°C / 176°F rated temperature, tinned stranded copper conductor, PVC insulation, PVC jacket, black and red conductor colors, and 5.1±0.15mm jacket diameter.
Please send the required length, quantity, connector or termination drawing, conductor colors and application details. Zhong Hua Jiang can review possible length and assembly configurations against the final specification and quotation.
Yes. Zhong Hua Jiang can support customization based on your required length, conductor configuration, connector type, cable assembly, and equipment application. Contact the sales team with your wiring diagram or technical requirement for a suitable solution.
The published PVC jacket diameter is 5.1 ± 0.15 mm. Check gland, conduit, connector boot and routing clearance against this tolerance.
Foil offers a continuous shielding layer, while a copper shielding layer can provide additional coverage and termination options. Performance depends on construction and termination. Request a drawing if the exact copper shield format is critical.
No. The 300V designation is a voltage rating; conductor ampacity, thermal conditions, installation rules and equipment type also determine whether a cable is suitable. High-power spindle or VFD outputs need appropriately specified motor cable.
It can be considered for compatible two-wire switch or sensor circuits where 20AWG size, voltage, current, insulation and installation conditions meet the design. Some devices require more than two conductors.
Shielding may help reduce interference in a noisy cabinet, but signal wires should still be routed with appropriate separation from VFD power conductors and terminated per the equipment design.
No. The shield is an electromagnetic compatibility component, not an automatic replacement for a dedicated protective-earth conductor. Follow the equipment manufacturer’s grounding and shield-termination instructions.
The standard configuration lists black and red insulated conductors. Confirm any custom color arrangement before production.
This cable is described as flexible, but no verified dynamic-bend life or minimum moving bend radius is specified. For continuous-motion applications, compare the purpose-built shielded chain cable category and request flex-test data.
No. The published conductor material is tinned stranded copper, not copper-clad aluminum (CCA). A current technical drawing or sample inspection can confirm the construction for the ordered variant.
The published electrical data lists 36.7 Ω/km at 20°C. Buyers using this value for voltage-drop or acceptance calculations should verify the test method and tolerance with the supplier.
The published dielectric-test notation is “2000AC V/min.” Because the notation does not fully describe the test setup, request the corresponding test standard, applied voltage, duration and acceptance criteria before using it as an engineering limit.
UL AWM Style 2464 describes a cable construction category associated with 80°C and 300V ratings; a style reference is not, by itself, proof that a specific supplier’s cable is certified. Request the applicable UL file and product labeling.
PVC (RoHS) is specified for both insulation and jacket. For regulated projects, request the specific material declaration or supporting compliance documentation for the supplied product.
No outdoor, sunlight-resistant, wet-location or direct-burial rating is stated in the supplied data. Use a cable explicitly rated for those environments when they apply.
Two conductors may be used in some balanced signaling schemes, but compatibility depends on the communication protocol, impedance, capacitance, shield strategy and cable construction. No characteristic-impedance rating is published here.
Provide the target quantity, cable length, circuit voltage and current, 20AWG/2-core requirement, drawings, shield termination, packaging and documentation needs. These inputs help the supplier review the proposed configuration.