14AWG 2 Core
Zhong Hua Jiang
14AWG
5m-5000m
2
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
9.25Ω/KM20℃
>10MΩ/KM20℃
12A
| Availability: | |
|---|---|

Zhong Hua Jiang 14 Gauge 2 Conductor Electrical Shielded Wire is a flexible 14/2 cable designed for applications that need stronger conductor capacity than small signal wire, while still requiring shielding against electromagnetic interference. It combines two twisted tinned-stranded-copper conductors, PVC insulation, aluminum shielding and a tinned-copper shielding layer inside a durable PVC jacket.
With a listed 300V voltage rating, 80°C temperature rating, 12A current rating and 9.25 Ω/km conductor resistance at 20°C, this 14 AWG 2-core shielded wire is suitable for CNC equipment wiring, motor auxiliary control, VFD-related low-voltage control circuits, power-limited control systems, electronic instruments, audio/control wiring, lighting control, security wiring and equipment connections where two conductors and EMI shielding are required.

This 14 AWG 2 conductor shielded wire is built for users who need a compact two-core cable for higher-current low-voltage control, power-limited circuits, signal/control pairs and machine-internal connections. The black and red conductor colors help simplify polarity, circuit identification and wiring verification during installation.
Compared with unshielded two-conductor wire, the aluminum and tinned-copper double shielding structure helps reduce interference from motors, VFDs, switching power supplies and nearby electrical devices. The tinned stranded copper conductors support conductivity, solderability, oxidation resistance and flexible handling during assembly.
Zhong Hua Jiang can supply this flexible electrical shielded wire in custom lengths for machine builders, maintenance teams, OEM equipment assembly, control-panel wiring and wholesale projects. Standard order discussions can include cable length, current requirement, roll packaging, application, quantity and destination-market requirements.
Request 14/2 Shielded Wire Pricing

| Rated Voltage | 300V | Number of Conductors | 2 twisted conductors |
| Rated Temperature | 80°C / 176°F | Wire Size | 14 AWG |
| Conductor Resistance | 9.25 Ω/km at 20°C | Conductor Material | Tinned stranded copper |
| Insulation Resistance | >10 MΩ/km at 20°C | Foil Orientation | One-side aluminum, aluminum facing outward |
| Electric Current | 12A | Insulation Material | PVC (RoHS) |
| Material Structure | PVC + tinned copper + aluminum | Jacket Material | PVC (RoHS) |
| Conductor Colors | Black and red | ||
| Jacket Diameter | 2.70 ± 0.05 mm | ||
| Available Length | 5 m to 5,000 m | ||
For accurate selection, confirm the required cable length, working current, voltage, conductor assignment, bend requirement, shielding termination and equipment electrical specifications before ordering. The listed 12A current rating should be checked against installation temperature, cable length, bundling, voltage drop and applicable electrical standards.

| UL2464 Product Configuration | Aluminum + Tinned-Copper Double Shielding | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistance |
14 AWG tinned stranded copper offers lower conductor resistance than thinner 18 AWG or 22 AWG cable, making it more suitable for higher-current control and auxiliary power circuits. The tinned surface improves solderability and helps resist oxidation in normal use.
| Advantage of Tinned Copper | |||
| Comparison Item | Tinned Copper | Pure Copper | CCACopper-Clad Aluminum |
| Easy to Solder | |||
| Better Conductivity | |||
| Anti-Oxidation | |||
| Anti-Corrosion | |||
| Sturdy and Durable | |||
Tinned copper offers excellent conductivity, prolongs service life and is more suitable for soldering.

The double shielded structure uses aluminum and tinned copper shielding to help achieve a stronger shielding effect than a basic unshielded cable. The shielding layer can help contain electromagnetic fields inside the cable and reduce external interference entering sensitive conductors.
In practical equipment wiring, the cable shield should be terminated according to the controller, VFD, motor or machine manufacturer's grounding and EMC instructions. The shield is used for interference control and should not be treated as a replacement for a required protective-earth conductor.
![]() | ![]() |
| Transformer | Electronic Instrument |
![]() | ![]() |
| Electrical Appliance | Motor |
This 14 AWG 2 conductor electrical shielded wire is widely used in electronic instruments and devices, electrical appliances, transformers, motors and CNC systems. It is also suitable for power-limited control circuits, audio and background-music wiring, intercom and security systems, remote-control circuits, lighting control, low-voltage equipment wiring and motor auxiliary control where a 14 AWG two-conductor shielded cable is required.
Whether the project is a CNC machine build, replacement cable, automation panel, spindle control system, auxiliary DC power line, brake or feedback wiring, audio control path, or compact electrical equipment assembly, Zhong Hua Jiang can help match the shielded wire configuration to the application. If the standard product does not meet the requirements, contact the sales team to discuss custom length and supply options.
Besides the 14 Gauge 2 Conductor 14/2 Flexible Electrical Double Shielded Wire UL2464, Zhong Hua Jiang offers other shielded cable options for diverse machine, control and signal-transmission requirements.

Huajiang was founded in 2000, initially producing CNC engraving spindle motors before expanding into variable-frequency drives, engraving machines, CNC accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 to support broader international-market development.
The company has more than 20 years of manufacturing experience in CNC-related products and holds a registered design patent for an air-cooled spindle-motor series, patent No. 200730184245.5. Products have been supplied to customers in multiple international markets.
![]() | ||
| Quality Assurance Product inspection and quality-control procedures before shipment. | Patents and Certifications Long-term CNC manufacturing experience and patented spindle designs. | Additional Brand Value Integrated product support for CNC machines, spindles, accessories and wiring. |
![]() | ||
| Reasonable Price Direct factory communication for specifications, quantities and custom lengths. | Full Time Service Technical support for cable gauge, conductor count and application selection. | Fast and Reliable Delivery Production coordination, shipment updates and export-order service. |
CNC router models such as 3018, 3020, 3040 and 6090 are available for engraving, cutting, prototyping and small-production applications.
Air-cooled and water-cooled spindle motors are supplied for different power, speed, cooling and machine-integration requirements.
The accessory range includes limit switches, Z probes, emergency-stop buttons and other components used to improve CNC-machine control, safety and setup accuracy.
Double-shielded cables and shielded chain cables are available in different gauges and conductor counts for CNC, VFD, motor, automation and electronic-equipment wiring.
Stepper motors are supplied for controlled motion in CNC machines, automation systems and related positioning applications.

Certification and compliance requirements can vary by market, machine and end use. Request the current product documentation needed for your order and verify that the selected cable satisfies the electrical, fire-performance and regulatory requirements of the final installation.

It is used for two-core higher-current control, auxiliary power and low-voltage equipment wiring where EMI reduction is important. Typical applications include CNC machines, VFD-related control circuits, motor auxiliary wiring, electronic instruments, transformers, power-limited control systems, security wiring, lighting control, audio/control signal paths and monitoring circuits.
“14/2” means the cable contains two insulated 14 AWG conductors. In this product, the two conductors are twisted and protected by aluminum and tinned-copper shielding layers inside an overall PVC jacket.
The listed rated voltage is 300V, the listed rated temperature is 80°C / 176°F and the listed current is 12A. Final suitability depends on circuit design, voltage drop, load type, installation environment, cable length, bundling and applicable standards.
The aluminum foil and tinned-copper shielding layers form conductive barriers around the insulated conductors. When terminated correctly, these layers help reduce interference from motors, VFDs, switching power supplies and other noise sources, improving stability in sensitive control or auxiliary-power wiring.
Shield termination depends on the equipment, frequency range, enclosure bonding and EMC design. Follow the CNC controller, VFD, motor or equipment manufacturer's wiring instructions. The cable shield should not replace a required protective-earth conductor.
14/2 shielded wire uses thicker 14 AWG conductors and is more suitable for higher-current control or auxiliary power circuits. 22/2 shielded wire is thinner and usually better for compact signal, sensor and light-duty control wiring.
It can be used for suitable motor auxiliary, feedback, brake, sensor or low-voltage control circuits when the electrical requirements match the cable rating. For main motor power, VFD output power or safety-critical wiring, confirm cable type, insulation rating, shielding method and applicable standards before use.
Standard flexible shielded cable may be suitable for fixed or occasional-flex installations. Continuous high-cycle motion generally requires a cable specifically designed for drag chains. Provide bend radius, travel distance, speed and cycle frequency so the proper cable type can be confirmed.
Yes. The available length range is 5 m to 5,000 m. Buyers can provide the required roll length, total quantity, packing preference, labeling needs, application and destination market for quotation confirmation.
Provide the cable gauge, conductor count, required length, estimated quantity, voltage, current, equipment model, installation movement, conductor-color requirement, termination method and delivery destination. These details help confirm the right cable and produce an accurate quotation.
Product categories undergo quality-control checks before leaving the factory, and shipment inspection is performed before dispatch. Buyers should request the current specification sheet, certification documentation and inspection requirements needed for their application.
Quick Links
Contact Us