16AWG 3 Core
Zhong Hua Jiang
16AWG
5m-5000m
3
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
14.6Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 16AWG 3-conductor double-shielded cable is designed for compatible CNC control circuits, electronic instruments, automation equipment and machine wiring where electromagnetic interference must be considered. Its three twisted, tinned stranded copper conductors are insulated with PVC and protected by aluminum and tinned copper shielding beneath a PVC jacket.
The published construction specifies a 300V voltage rating, 80°C temperature rating and 7.2 ± 0.15mm outer diameter. Equipment designers should confirm current load, cable routing, termination and environmental conditions against the electrical requirements of each installation.
Request 16AWG 3-Core Cable Pricing
This 16/3 cable combines three separately insulated conductors with two conductive shielding materials. The aluminum shield provides a barrier against electromagnetic coupling, while the tinned copper shield offers an additional conductive path for appropriately designed shield termination. Actual shielding effectiveness depends on coverage, frequency, connectors and installation practice.
Tinned stranded copper supports wire termination and soldering applications where compatible connectors and assembly practices are selected. The PVC insulation and sheath provide conductor separation and protection within the published ratings; suitability for chemicals, outdoor exposure or continuous movement must be evaluated separately.

Ask for Cable Construction Details
For industrial procurement, the principal decision is whether the cable construction matches the intended control or equipment-interconnection circuit. This 16 gauge, 3-core shielded wire is relevant to equipment builders, automation integrators, OEM purchasers, maintenance teams and electrical distributors evaluating noise-sensitive wiring.
Applications may include control cabinets, electronic instruments, sensor connections, monitoring circuits, machine wiring and auxiliary connections associated with motors or transformers. The shield is not a protective-earth conductor, and the cable should not be assumed suitable for VFD-to-spindle power or continuous-flex drag chains without additional product-specific validation.
Purchasers comparing quotations should specify the requested length and quantity, conductor identification, voltage and temperature requirements, desired termination method, machine environment and any standards or test reports required by the project.
Get an OEM or Wholesale Cable Quote
The following table retains the technical values published for Zhong Hua Jiang 16AWG 3-conductor double-shielded wire. Where the original datasheet uses abbreviated test units, ask for the applicable test method before approving the cable for a regulated or safety-critical design.

Rated Voltage: | 300V | Number of Conductors: | 3 Twisted |
Rated Temperature: | 80°C / 176°F | Size: | 16AWG |
Conductor Resistance: | 14.6Ω/KM 20°C | Conductor Material: | Tinned Stranded Copper |
Insulation Resistance: | 10MΩ/KM 20°C | One Side Aluminum (AL Facing Outside) | |
Dielectric Test: | 2000AC V/min | Insulation Material: | PVC (RoHS) |
Material: | PVC + Tinned Copper + Aluminum | Jacket Material: | PVC (RoHS) |
Conductor Color: | Black, Red, Yellow | ||
Jacket Dia(mm): | 7.2 ± 0.15mm | ||
Specification review: The original figures for insulation resistance (10MΩ/KM at 20°C) and dielectric testing (2000AC V/min) are reproduced as published. Confirm the exact measurement units, applied voltage, test duration and acceptance criteria with the technical team.
The listed core colors are black, red and yellow. Wire color alone does not define electrical polarity, phase or protective-earth function; the equipment wiring diagram governs terminal assignments.
Request Technical Data and a Quotation
For industrial signal and control wiring, shielding, conductor construction and cable dimensions can influence assembly quality and electromagnetic compatibility. The images and comparison charts below illustrate the materials and features presented by Zhong Hua Jiang.

| UL Status: Confirm File Number | Double Shielded | Tinned Copper Core |
Tinned copper, controlled insulation consistency and a two-material shielding structure are practical selection factors for instrument and machinery wiring. Their relative advantages depend on conductor size, operating conditions and the full cable assembly.

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |
The original conductor comparison chart is included below. Tin plating primarily supports surface protection and solderability; it should not be interpreted as inherently providing greater bulk electrical conductivity than bare copper of the same cross-sectional area.
Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Soldering Surface | |||
| Copper Conductivity | |||
Anti-oxidation | |||
Anti-corrosion | |||
Sturdy and Durable | |||
The foil and tinned-copper shielding materials are intended to help manage electrical noise when the shield is terminated according to the equipment grounding and EMC design.

Shield termination: Make the shield connection as specified in the equipment or drive installation manual. A shield helps control interference but must not replace the dedicated protective-earth conductor or the required protective devices.
Discuss Shielding and Installation Requirements
Potential uses include equipment interconnections, instrument wiring, control panels, CNC auxiliary circuits, automation interfaces and electrical devices that require three insulated conductors and a shielded cable path. The illustrations below show representative equipment categories, not universal approval for every electrical circuit.
|
|
| Transformer | Electronic Instrument |
|
|
| Electrical Appliance | Motor |
Application limits: Confirm circuit current, voltage, operating temperature, bending conditions, installation environment and electrical codes. For high-frequency inverter output or moving cable carriers, obtain a cable specifically qualified for the required installation duty.
Check Your Industrial Cable Application
Explore Zhong Hua Jiang electrical chain-shielded cables and double-shielded cable categories if your equipment requires a different conductor count, wiring configuration or movement duty. The exact ratings and suitability of each cable are model-specific.

Huajiang began manufacturing CNC engraving spindle motors in 2000 and later expanded its range to include VFDs, CNC machinery, accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 for international markets.

The company identifies an air-cooled spindle motor patent, Patent No. 200730184245.5, as part of its manufacturing background. For cable orders, purchasers can discuss the required construction and documentation with the supplier.
![]() | ||
Quality Assurance Superior quality performance Strict quality control | Patents and CertificationsSeveral patents for air-cooled spindle motors | Additional Brand ValueBrand value highly recognized by the market |
![]() | ||
Reasonable PriceDirect factory sales High cost performance | Full Time ServiceProfessional technical support Quick customer service | Fast and Reliable DeliveryFast and efficient delivery Real-time tracking and updates |
For project sourcing, confirm the approved specifications, applicable inspection documents, packaging, delivery arrangements and after-sales contact procedures in the purchase order.
Zhong Hua Jiang supplies CNC spindle motors, router machines, associated machine components and electrical cable products for professional equipment projects.
The CNC router portfolio includes model families such as 3018, 3020, 3040 and 6090 for engraving and machining applications.
Air-cooled and water-cooled spindle motors are offered for CNC routers and engraving machines; select by spindle power, speed and machine interface.
Machine accessories include limit switches, Z probes, emergency-stop components and related electrical products.
The cable range includes double-shielded electrical cables and shielded chain cables with different intended installation duties.
Stepper motor products support machine-axis positioning and related automated motion systems.
Contact Zhong Hua Jiang for B2B Enquiries

The illustration above presents company certification materials. Certification must be checked for the exact cable construction and order; request the relevant file number, certificate scope and applicable test documents where these are required by your purchasing specification. A cable style reference alone does not establish product certification.

Customer feedback provides context about prior purchasing experiences. Equipment manufacturers should independently assess cable specifications, installation conditions and required conformity documentation before selecting a cable for production use.
It is a three-core electrical cable with 16AWG tinned stranded copper conductors, PVC insulation and jacket, and two shielding materials: aluminum and tinned copper. The published outer diameter is 7.2 ± 0.15mm.
The published ratings are 300V and 80°C (176°F). These ratings do not establish ampacity or suitability for every machine installation; the equipment designer must evaluate the intended circuit.
The original product specification lists black, red and yellow. Confirm conductor identification against the wiring drawing; do not assume that a yellow core serves as protective earth.
The published construction uses aluminum shielding and a tinned-copper shielding layer around the insulated conductors. This arrangement may help reduce coupled electrical noise when properly installed.
The conductive shielding materials can reduce coupling from nearby interference sources. Actual performance depends on shield coverage, frequency, cable routing, connectors, shield termination and installation layout.
No. The shield is intended for electromagnetic interference control and must not be treated as a substitute for a designated protective-earth conductor, protective device or equipment-specific grounding arrangement.
It may be considered for compatible CNC control, instrument and machine-interconnection circuits within its electrical ratings. Review the control-system documentation, current requirements and termination method before ordering.
Do not assume so. VFD motor-output cables may require specific voltage, insulation, conductor, shielding and EMC characteristics. Use a cable expressly approved for the inverter and motor arrangement.
Suitability depends on operating voltage, load current, duty cycle, installation method and applicable regulations. The published cable specification does not give a verified ampacity, so a current rating must not be inferred from AWG size alone.
This model has three insulated conductors, not three pairs of conductors. Three-pair cable typically contains six insulated conductors arranged as three pairs.
For otherwise comparable copper constructions, 16AWG offers more conductor cross-sectional area and lower resistance than 18AWG. Selection still requires circuit-current, voltage-drop and installation calculations.
The original product data states 7.2 ± 0.15mm. Allow for this tolerance when selecting conduit space, glands, clamps and connector strain relief.
The product specification states 14.6 Ω/km at 20°C. For designs that require verified conductor resistance, obtain the relevant test report and confirm the measurement method and tolerance.
Continuous-flex service is not established by the published construction. Ask for the minimum dynamic bend radius, cycle-test method and intended movement duty, or select a dedicated rated drag-chain cable.
The provided product data does not specify an ingress-protection rating, UV resistance or outdoor certification. Confirm environmental suitability separately before installation.
The published temperature rating is 80°C. Do not apply the cable above its specified temperature limit without an alternative, qualified cable specification.
The original promotional chart refers to UL, but a current product-specific certification file was not provided in the published data. Request the file number and verify the relevant cable construction and markings for the exact order.
The published specification describes the PVC insulation and jacket as RoHS. If regulatory documentation is required, request a current declaration or supporting test documentation for the applicable construction.
Foil provides broad-area coverage, while a copper shield can assist with electrical continuity and cable termination. Exact shielding coverage and physical construction should be confirmed in the technical datasheet.
Follow the equipment manufacturer’s EMC and grounding instructions. Termination at one or both ends depends on circuit design, frequency, noise source and safety requirements; there is no universal connection rule.
The original table lists 10MΩ/KM at 20°C and 2000AC V/min. Ask for the complete test procedure, measurement units and acceptance criteria before using these figures in a qualification document.
Cable length, conductor colors, labeling, packaging and construction changes can be discussed with the sales team. Feasibility, minimum quantities and lead times must be confirmed for the requested configuration.
Provide the 16AWG three-core cable specification, required length per piece or reel, purchase quantity, delivery market, equipment application and any certification or test documentation needed. The supplier can then review the enquiry.