22AWG 2 Core
Zhong Hua Jiang
22AWG
5m-5000m
2
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
13.7Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22AWG 2-conductor shielded drag chain cable is intended for compact signal and control wiring in CNC machines, sensor circuits, industrial automation equipment and moving cable carriers. Two twisted tinned stranded copper conductors, PVC insulation, an overall shield and a flexible PVC jacket provide a practical construction for space-limited wiring routes.
This 22/2 shielded chain cable has a published 300V voltage rating, 80°C (176°F) temperature rating, black and white conductors, and a 4.5 ± 0.3mm outer diameter. It can be considered for compatible low-current sensor, switch and control circuits after the electrical load and repeated-motion requirements are checked.
Request 22AWG 2-Core Cable Pricing
The cable contains two twisted 22AWG insulated tinned-copper conductors. The strands support flexibility and practical solder termination. PVC insulation separates the cores, cotton rope and cotton paper are listed as internal filling or separation materials, and the outer shield helps reduce electromagnetic coupling into nearby signal wiring.
For an OEM wiring harness, check the conductor gauge, insulation and jacket, shield construction, required cable length and environmental conditions. The approved wiring drawing should identify both conductors and the correct connections before the cable is installed in an electrical cabinet or moving cable chain.

For machine builders, automation integrators, importers and cable distributors, this two-core 22AWG shielded chain cable is an option for a simple two-conductor circuit. Typical use cases include compatible CNC limit-switch wiring, low-current sensor leads, controller input circuits and compact motion-system interconnections.
Shielding can help reduce electromagnetic interference from motor drives, variable-frequency drives, switching devices or nearby power circuits when the shield is correctly terminated and routed. It cannot replace required protective bonding, and a two-core signal cable should not automatically be used for spindle motor power.
Request a quotation with your required cable length, order quantity, machine application, voltage and current, connector requirements, drag-chain movement details and preferred packing. Selection should follow the approved technical documents for the exact cable model.

| Rated Voltage: | 300V | Number of Conductors: | 2 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 22AWG |
| Conductor Resistance: | Confirm conductor resistance for the exact 22AWG cable | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White | ||
| Jacket Dia(mm): | 4.5 ± 0.3 | ||
This cable is listed with 22AWG black and white conductors, 300V and 80°C ratings, PVC insulation and jacket, and a 4.5 ± 0.3mm overall diameter. For accurate voltage-drop and signal-circuit calculations, request the current model-specific conductor resistance value and test report before approving the cable.
When electrical testing is required, request the insulation-resistance and dielectric-withstand test method, voltage, duration and acceptance criteria for the ordered cable.
Request a Verified Cable Datasheet

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The flexible drag-chain design is intended for repeated movement in cable carriers. Marketing materials mention 15 million bending cycles; actual cable lifetime depends on the specific test conditions and application, which should be confirmed before design approval.
Cable-carrier compatibility depends on the manufacturer-approved minimum dynamic bend radius, travel distance, motion speed, acceleration, cable separation and strain relief. Obtain these values for the ordered 22AWG two-core cable.
With a 4.5 ± 0.3mm jacket diameter, this cable can suit compact wiring routes where a two-conductor shielded cable is required. Verify the cable-channel dimensions and allowable bending radius rather than relying on diameter alone.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned stranded copper helps protect exposed strands against surface oxidation and can simplify solder termination.
Service life is affected by the conductor stranding, insulation construction and movement conditions.
Check the verified conductor resistance, circuit current, line length and termination method when assessing signal quality and voltage drop.

An overall cable shield can reduce coupled electrical noise around sensitive control and sensor circuits.
For CNC equipment, follow the control or equipment manufacturer’s instructions for cable separation, shield bonding and grounding.
The shield is not a protective-earth conductor. Any required protective grounding must be provided independently through the machine’s approved wiring design.
Product literature references 15 million flex cycles, but the service life of a drag-chain cable depends on the specified bend radius, stroke length, speed, acceleration, cable-carrier layout and environmental conditions. Ask for a relevant test report rather than treating the cycle count as an unconditional operating-life guarantee.
Discuss Your Drag Chain Application

Designed for shielded two-conductor connections in compact cable carriers and moving control assemblies.
Potential applications include CNC sensor circuits, limit switches, control panels, positioning systems and compatible robotics wiring.
This 22AWG two-core shielded cable is suited to applications where two insulated conductors are required for a low-current signal or compatible control circuit. The cable does not by itself establish suitability for a particular communications bus, servo drive output or CNC spindle power circuit.
For an accurate cable quotation, provide the electrical diagram, current and voltage, the required cable length, cable-carrier bend radius, stroke length, travel speed, environmental conditions, any connector specifications and the expected order quantity.
Start with the circuit requirements: two insulated conductors, allowable operating current, voltage, intended signal type and required screening against electrical noise. Confirm the cable diameter and dynamic movement conditions separately. The overall shield is not an additional insulated conductor or a substitute for protective earth.
22AWG is a smaller conductor gauge than 18AWG or 16AWG and is often selected for low-current sensor and control connections. Larger copper conductors generally have lower resistance and may suit higher-current or longer wiring runs, but the permitted current still depends on the cable construction, installation, ambient temperature and applicable equipment requirements.
| Cable choice | Conductor arrangement | Selection consideration |
| 22AWG × 2 | Two smaller-gauge insulated conductors | Compact, compatible low-current signal and control circuits |
| 18AWG × 2 | Two larger-gauge insulated conductors | Applications that require a larger conductor cross-section |
| 16AWG × 2 | Two still larger-gauge insulated conductors | Applications with higher current or voltage-drop considerations, subject to approved ratings |
The listed jacket diameter of 4.5 ± 0.3mm is useful when selecting glands, connectors and compact cable-chain compartments. Verify the manufacturer-recommended minimum dynamic bend radius and ensure that the cable has suitable movement clearance, support and strain relief.
An overall cable shield can help reduce electromagnetic coupling when installed correctly, but its effectiveness also depends on routing, termination and enclosure bonding. For protocols that require a particular characteristic impedance or pair geometry, ask for the full construction drawing. The two-core cable is not automatically suitable for a VFD spindle motor output or protective-earth circuit.
Explore Zhong Hua Jiang shielded drag-chain cables and other electrical wire constructions for CNC machines. Compare the number of cores, conductor gauge, cable diameter and motion requirements before selecting a cable type.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company supplies CNC router machines for engraving, cutting and related machining tasks, including 3018, 3020, 3040 and 6090 configurations.
Air-cooled and water-cooled CNC spindle motors are offered for different machine power, speed, cooling and integration needs.
The CNC accessory range includes limit switches, Z probes, emergency-stop buttons and related machine-control components.
Electrical wire products include shielded drag-chain cables for moving installations and other shielded cable constructions for compatible equipment wiring.
Stepper motors are available for controlled positioning in CNC machines and other automation assemblies.
When requesting a quotation, provide 22AWG × 2 cores, required cut or reel length, quantity, CNC or automation equipment application, circuit voltage and current, moving-carrier details, desired terminations, packaging and delivery destination.
For installations that require traceability or compliance evidence, request the current cable-specific drawings, conductor-resistance report, flex-test conditions and any applicable approval documents for the exact part number. Product-family marketing documents should not be taken as a model-specific compliance certificate.
Request OEM or Wholesale Pricing

The documents shown above may relate to a wider product range. Request documents corresponding to the ordered 22AWG two-conductor cable when application-specific certification or compliance is required.

The 22AWG two-conductor shielded chain cable is intended for CNC, automation, sensor, switch and compatible control wiring where two insulated conductors and a shield are needed in a moving cable carrier.
Shielding helps limit interference coupling when properly installed near power supplies, motors and motor drives. Shield termination, signal routing, separation from power circuits and equipment bonding all affect the practical noise performance.
The cable is presented for drag-chain applications, but a specific minimum bend radius, stroke, speed and flex-life test procedure are not supplied in the product table. Obtain these requirements before selecting it for a moving machine.
The listed specifications include two twisted 22AWG tinned-stranded copper conductors, a 300V rating, an 80°C (176°F) temperature rating, PVC insulation and jacket, black and white cores, and a 4.5 ± 0.3mm outer diameter. Request current resistance and dielectric-test data for the purchased item.
The two insulated core colors are Black and White according to the published product description. Confirm the intended terminal assignments using the equipment wiring diagram rather than assuming polarity from wire color.
Tinned stranded copper provides useful electrical conductivity, solderability and improved resistance to oxidation of exposed conductor surfaces; the individual strands also contribute to cable flexibility.
Cut lengths, core identification, jacket requirements, packaging and other project-specific arrangements can be discussed. Provide your intended application, cable drawing and estimated purchasing quantity for confirmation.
Specify 22AWG × 2 conductors, cable length, total volume, electrical load, the required shield termination, movement data, connector or gland details, destination market and any necessary compliance documentation.
Huajiang began manufacturing CNC spindle motors in 2000 and subsequently expanded into VFDs, CNC router machines, accessories and electrical cable products. The Zhong Hua Jiang brand was introduced in 2018 for international markets.
22/2 denotes two insulated 22AWG conductors. This cable is described as two twisted tinned-copper cores within PVC insulation and jacket, with an overall shield for compatible moving-machine wiring.
The published outside diameter is 4.5 ± 0.3mm. Check cable-gland, connector, cable-carrier clearance and strain-relief dimensions against the approved drawing.
The provided specification lists 300V and 80°C (176°F). These ratings do not by themselves establish permitted circuit current or suitability for a particular drive output.
Ask for a current cable-specific datasheet or measured conductor-resistance report. Cable length and loop resistance should be considered for voltage-drop and signal-integrity calculations.
The listed core colors are Black and White. Always follow the equipment wiring diagram to determine the function of each conductor.
22AWG is a smaller conductor size than 16AWG. Conductor resistance and current capacity generally differ; evaluate cable length, voltage drop, installation temperature and the required circuit current before substituting gauges.
Yes. The cable has tinned stranded copper conductors, PVC insulation and jacket, with cotton rope and cotton paper listed within its construction.
It is marketed for repeated movement in drag-chain installations. Obtain a model-specific dynamic bend-radius limit and verify travel length, movement speed and chain layout.
A numeric minimum bending radius is not provided in the supplied product specification. Use the manufacturer-approved static and dynamic bend radii for the exact product rather than estimating from its outside diameter.
The marketing material mentions 15 million flex cycles, but lifetime depends on documented test and installation conditions. Request the specific flex-test report for the selected part number.
A properly installed cable shield helps reduce unwanted electromagnetic coupling into sensitive signals. Grounding, termination, routing and separation from motor-power cables remain important.
No. A cable shield is for electromagnetic control and should not replace a required protective-earth conductor in the machine wiring design.
A characteristic impedance and protocol-specific pair rating are not stated for this cable. Check the requirements of your communications protocol and request a detailed cable construction drawing.
Do not assume so. Check the VFD motor-output cable specification, required conductor arrangement, insulation ratings, current and protective-earth provisions. This 22AWG two-core cable is primarily described for compact signal and control connections.
The supplied specification lists PVC but no explicit oil, UV, outdoor or chemical exposure rating. Request test documentation or an alternative material when such resistance is needed.
UL and RoHS references appear in product materials. Request current compliance declarations or approval records applicable to the exact ordered part number.
Provide 22AWG × 2, the cut or reel length, quantity, destination, use case, voltage and current, operating conditions, connector requirements and requested technical documentation.
Yes. Share the required lengths, quantities, cable construction, core identification and packing requirements for confirmation of available options and a project quotation.
Quick Links