22AWG 5 Core
Zhong Hua Jiang
22AWG
5m-5000m
5
Tinned stranded copper
PVC(RoHS)
300V
80℃/176℉
40.1Ω/KM20℃
10MΩ/KM20℃
2000AC V/min
| Availability: | |
|---|---|

Zhong Hua Jiang 22AWG 5-conductor shielded drag chain cable is designed for compatible CNC control, sensor wiring, industrial automation and moving cable carrier assemblies. Five stranded tinned-copper conductors, PVC insulation and jacket, and shielding help provide multiple insulated electrical paths within one compact cable.
The supplied product specifications identify five twisted 22AWG cores, a 300V voltage rating, an 80°C (176°F) temperature rating and a 6.0 ± 0.3mm cable outside diameter. Check current, signal requirements, line length, electrical noise exposure and dynamic movement before specifying this cable for machinery.
Request a 22AWG Five-Core Cable Quote
Five insulated stranded tinned-copper conductors form the cable core within a shielded construction. The supplied description identifies PVC conductor insulation and jacket materials, with cotton rope and cotton paper filling. Confirm the number and position of cores using the approved cross-sectional drawing.
Ask for model-specific shielding details, conductor color identification, conductor resistance test data and dynamic bend-radius guidance before specifying a five-core cable for an OEM equipment program or distributor order.

This 22AWG five-core shielded drag-chain cable is a potential fit for suitable multi-wire sensor interfaces, low-current machine-control assemblies and CNC cable carrier routes where five individual insulated conductors are required.
A properly terminated cable shield helps manage interference coupled from nearby drives and electrical controls. Separation, bonding, and the controller maker’s grounding instructions matter. The shield is not an extra insulated signal core or a replacement for protective earthing.
Specify 22AWG × 5, required lengths and quantities, voltage and current, equipment model, controller or sensor connection, cable carrier movement, termination details, and delivery destination when requesting pricing.

| Rated Voltage: | 300V | Number of Conductors: | 5 Twisted |
| Rated Temperature: | 80°C / 176°F | Size: | 22AWG |
| Conductor Resistance: | 40.1 Ω/km at 20°C (as published; verify test report) | Conductor Material: | Tinned Stranded Copper |
| Insulation Resistance: | 10MΩ/KM 20°C | Insulation Material: | PVC (RoHS) |
| Dielectric Test: | 2000AC V/min | Isolation Material: | Cotton Rope and Cotton Paper |
| Material: | PVC + Tinned Copper | Jacket Material: | PVC (RoHS) |
| Conductor Color: | Black, White, Yellow and Green, Red, Green | ||
| Jacket Dia(mm): | 6.0 ± 0.3 | ||
The manufacturer-supplied technical table lists 40.1 Ω/km conductor resistance at 20°C. Request a measurement report for this particular 22AWG five-conductor model before using the figure in voltage-drop or control-circuit calculations.
The supplied data also lists insulation resistance and dielectric testing, while other page material refers to UL and RoHS. Ask for measurement units, test methods, current certificates and applicability to the ordered cable model.
Request Five-Core Cable Technical Documents

| UL Documentation: Verify by Cable Model | 15 Million Flex Cycles — Test Conditions on Request | Shielded | Tinned Copper Core |

![]() | ![]() | ![]() | ![]() |
| Oxidation Resistance | Low Eccentricity | High Conductivity | Insulation Resistant |

The cable is marketed for moving drag-chain installations. Promotional material mentions 15 million bending cycles, but actual mechanical life depends on testing and operating conditions; obtain the relevant test report before using a cycle count as a design limit.
Check the cable manufacturer’s minimum dynamic bend radius, drag-chain travel distance, speed, acceleration, installation clearance and strain relief. No single bend-radius value can be reliably inferred from the outside diameter alone.
The listed 6.0 ± 0.3mm outside diameter supports initial selection of cable-chain clearance, strain relief and entry glands. Final selection must use an approved cable drawing and the relevant installation and bend-radius limits.
| Advantage of Tinned Copper | |||
![]() | ![]() | ![]() | |
| Tinned Copper | Pure Copper | CCA Copper Clad Aluminum | |
| Easy to Solder | |||
| Copper Conductor Performance | |||
| Anti-oxidation | |||
| Anti-corrosion | |||
| Application-Dependent Durability | |||
Tinned stranded copper combines electrical conductivity with practical solder termination and resistance to oxidation at exposed strand surfaces.
Cable service life depends on conductor stranding, jacket construction, bend radius, carrier travel and installation conditions.
Use the verified conductor resistance and total run length to assess voltage drop and signal integrity for the actual circuit.

The cable shield can help reduce unwanted electromagnetic interference from adjacent electrical equipment when correctly installed.
For sensitive control and sensor circuits, check the machine maker’s instructions for shield termination, separation from motor-output cables and electrical bonding.
A cable shield does not replace a dedicated protective-earth conductor. Follow the machine’s approved safety and grounding design.
Promotional material refers to 15 million flex cycles, but does not show dynamic bend radius, travel, speed, loading or pass criteria. Confirm the tested operating profile and cable-carrier installation requirements before choosing a replacement or making an expected-life calculation.
Discuss Cable Carrier Requirements

A compact five-core shielded cable option for appropriate control and signal wiring routed through moving industrial cable carriers.
Potential applications include compatible multi-core CNC interfaces, machine switches, sensor connections, automation equipment and control cabinet wiring with appropriate electrical engineering approval.
The five-conductor 22AWG cable provides five insulated paths for compatible control or sensor circuits. Conductor count does not establish suitability for a specific encoder, serial link, VFD motor output, safety circuit or protocol; confirm the actual electrical requirements.
To request an OEM or distributor quotation, submit cable quantity, needed cut or reel length, five-core connection diagram, 300V/80°C suitability, current, carrier stroke and bend radius, intended installation environment, connectors and packaging preferences.
Five insulated 22AWG conductors can simplify compatible multi-wire sensor and control connections where a shielded cable is specified. Review machine pinout, cable runs, current demand, moving installation and noise environment. Shielding is not a sixth insulated core.
Choose conductor count from the equipment connection diagram. Other electrical characteristics, connector layout and safety-earth requirements must also be reviewed.
| Cable selection | Insulated conductors | Typical design assessment |
| 22AWG × 3 | 3 | Compatible three-wire sensor/control connection |
| 22AWG × 4 | 4 | Compatible four-wire signal or control connection |
| 22AWG × 5 | 5 | Compatible five-wire sensor or multi-signal connection |
The supplier lists an outside diameter of 6.0 ± 0.3mm. Check available drag-chain clearance, cable separation, minimum permitted dynamic bend radius and gland/strain relief dimensions. The suitable bend radius is not established by diameter alone.
The published colors are Black, White, Yellow and Green, Red, Green. Ask whether Yellow/Green refers to one striped core and confirm the five individual conductor assignments before termination. A yellow/green designation must be interpreted in accordance with the relevant equipment safety design.
Confirm current, total conductor path length and acceptable voltage drop for sensor power or control loops. The quoted 40.1 Ω/km resistance needs an up-to-date report for the exact product. Cable shielding alone does not prove a specific communications protocol rating.
Send Five-Conductor Cable Specifications
Explore the shielded drag-chain and double-shielded wire ranges from Zhong Hua Jiang. Compare conductor count, wire gauge, moving versus fixed installation and cable dimensions before selecting an equivalent wiring product.


Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.
The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.
![]() | ||
| Quality Assurance Superior quality performance Strict quality control | Patents and Certifications Several patents for air-cooled spindle motors | Additional Brand Value Brand value highly recognized by the market |
![]() | ||
| Reasonable Price Direct factory sales High cost performance | Full Time Service Professional technical support Quick customer service | Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates |
The company offers CNC router machine configurations such as 3018, 3020, 3040 and 6090 for engraving, cutting and related machining work.
The product range includes air-cooled and water-cooled spindle motors for different CNC machine power and cooling requirements.
CNC accessories include limit switches, Z probes, emergency-stop buttons and related machine-control parts.
The electrical wire range includes shielded drag-chain cables for moving applications and other shielded wire constructions for equipment wiring.
Stepper motors are used for controlled positioning in compatible CNC and automation systems.
For a purchase inquiry, list 22AWG × 5, cut or reel lengths, intended volume, electrical application, cable motion, terminations, local environmental conditions, packaging preferences and receiving market.
Request a current product drawing, five-core conductor color map, material details, shielding construction, conductor-resistance test data and any applicable conformity records before confirming a technical specification.
Request OEM / Distributor Pricing

Company-level documentation may cover multiple product families. For a technical purchasing decision, request applicable documents that identify the 22AWG five-conductor cable being ordered.

The cable is intended for suitable 22AWG × 5 low-current control or signal connections in CNC machinery, sensor assemblies and cable drag chains where an overall shield can help manage electrical interference.
Shielding helps limit coupled electrical noise near drives, switching devices and power cables when installed correctly. Route and terminate the shield according to the controller and equipment manufacturers’ requirements.
The product is presented for cable-carrier movement. However, minimum dynamic bend radius, working speed, stroke length and flex-test conditions are not stated in the supplied technical table. Request these data for the specific ordered cable.
The published specifications identify five twisted 22AWG stranded tinned-copper conductors, 300V, 80°C, PVC insulation and jacket, and a 6.0 ± 0.3mm outside diameter. The 40.1 Ω/km resistance at 20°C is a supplier-published value requiring model-specific verification.
The published conductor-color field reads Black, White, Yellow and Green, Red, Green for a five-core cable. Check the approved color drawing to establish whether Yellow/Green denotes one striped core, and follow the approved electrical pinout for every conductor.
Tinned stranded copper combines useful conductivity, solderability and oxidation resistance at strand surfaces. Flexibility and service life depend on the complete cable construction and operating conditions.
Discuss cable length, conductor identification, jacket requirements, packaging and other project-specific features with Zhong Hua Jiang. Final custom arrangements are subject to technical confirmation.
Send 22AWG × 5, requested cable length, order volume, machine details, operating voltage and current, drag-chain motion requirements, connector size, destination and documentation expectations to discuss a quotation.
Huajiang began producing CNC spindle motors in 2000, expanding into VFDs, CNC router machines, accessories and electrical wire products. The Zhong Hua Jiang brand was established in 2018 for international markets.
It contains five insulated 22AWG cores within a shielded cable assembly. The cable description identifies twisted tinned stranded copper conductors, PVC insulation and a PVC outer jacket.
The published diameter is 6.0 ± 0.3mm. Confirm it with the cable drawing before selecting a gland, conduit entry or cable carrier.
The original table lists 300V rated voltage and 80°C (176°F) rated temperature. Current-carrying capability and installation suitability must be assessed separately.
The supplied table lists 40.1 Ω/km at 20°C. Ask for a current measurement report before using this value to calculate voltage drop.
The supplier lists Black, White, Yellow and Green, Red, Green. Confirm whether Yellow/Green denotes one striped wire, and verify all five cores with the model-specific wiring diagram.
Do not assume a conductor function from a text list alone. The approved color map, safety standards and machine wiring diagram determine any protective-earth assignment.
Five-core provides five individual insulated wires, compared with three or four in the other options. Match the number and assignment of cores to the device’s actual wiring requirements.
It is presented as a flexible cable-chain product. Confirm approved dynamic bend radius, stroke, speed, installation method and cable load for your application.
No numerical bend-radius limit is provided in the published product specifications. Request the manufacturer’s model-specific dynamic radius and installation guidance.
A promotional cycle count cannot guarantee service life for every installation. Request the tested bend radius, travel, speed, loading and failure criteria for the exact model.
Tin plating can reduce oxidation of exposed copper strands and assist with soldered terminations. Stranding supports flexibility when the full cable construction is appropriate for movement.
A properly routed and terminated shield can help reduce coupled electrical interference in suitable control applications. Termination design and separation from drive power wiring also matter.
No. A shield intended for noise control must not replace a required protective-earth conductor. Use the approved equipment grounding design.
Do not assume so. A spindle/VFD motor output needs cable current rating, insulation, shielding and grounding selected to match the specific drive and motor manuals.
The available product specifications does not supply characteristic impedance, capacitance or communications-protocol compliance. Verify those requirements separately.
The specification states PVC insulation and jacket but does not establish oil, chemical, UV or outdoor environmental ratings. Obtain a model-specific material declaration where needed.
The product imagery references UL and RoHS beside PVC materials. Request applicable current documents stating the exact cable identification and standards.
Supply the desired 22AWG × 5 cable configuration, quantity, cut or reel lengths, electrical application, required documentation, destination and packaging instructions.
Provide the desired changes, drawings, purchase quantity and intended operating environment to discuss feasibility with the supplier.
Select compatible components using the specified 6.0 ± 0.3mm outside diameter, termination details, sealing and strain-relief needs, and expected movement.
Quick Links