Please Choose Your Language
You are here: Home » Products » Shielded Wire » Shielded Chain cable » 20AWG » Zhong Hua Jiang 20AWG 4-Core Shielded Drag Chain Cable

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Zhong Hua Jiang 20AWG 4-Core Shielded Drag Chain Cable

Zhong Hua Jiang 20AWG 4-core shielded drag chain cable features four twisted tinned copper conductors, PVC insulation and jacket, 300V/80°C ratings and a 7.4mm outside diameter.
  • 20AWG 4 Core

  • Zhong Hua Jiang

  • 20AWG

  • 5m-5000m

  • 4

  • Tinned stranded copper

  • PVC(RoHS)

  • 300V

  • 80℃/176℉

  • 40.1Ω/KM20℃

  • 10MΩ/KM20℃

  • 2000AC V/min

Availability:

20 AWG 4-Conductor Shielded Drag Chain Cable

Zhong Hua Jiang 20 gauge 4 conductor electrical chain shielded wire

Zhong Hua Jiang 20AWG 4-conductor shielded drag chain cable is offered for compatible CNC control wiring, automation equipment and moving cable carriers. The described construction has four twisted insulated tinned-stranded copper cores, PVC insulation and an outer PVC jacket, plus a shield intended to help reduce coupled electrical noise.

The published cable table specifies a 300V rating, an 80°C (176°F) temperature rating and a 7.4 ± 0.3mm outer diameter. Select the cable against the machinery drawing, conductor functions, operating current, cable run length, motion profile, electrical environment and cable-carrier clearance.

20AWG 4-Core Shielded Cable Construction

The manufacturer-described construction contains four twisted tinned-stranded copper conductors, PVC core insulation, an overall shield and a PVC outer jacket. Cotton rope and cotton paper are also identified as filling materials. Obtain the exact cross-sectional drawing and shielding details for design approval.

For OEM machine integration, confirm that four separately insulated conductors are required. Review conductor identification, shield bonding, connector or gland fit, voltage and temperature limits, carrier motion, compatible termination practices and the application environment.

electrical shielded wire layout for CNC and automation wiring

Request a Quote for 20AWG 4-Core Shielded Cable

20AWG 4-Conductor Shielded Cable for OEM Supply

CNC machine manufacturers, integrators, electrical workshops and cable distributors may evaluate this 20AWG × 4 shielded cable for compatible four-conductor control and sensor circuits in moving equipment.

An appropriately installed overall screen can help reduce electromagnetic noise coupled into sensitive control wiring. Use the CNC controller and electrical drive manufacturer’s recommendations for shield bonding and separation from inverter output leads. Do not treat the overall shield as an additional insulated conductor or a protective-earth replacement.

For quotation or technical qualification, identify the 20AWG × 4 model, length per machine, annual or project quantity, machine type, required cable carrier travel, connector arrangement, working voltage/current and any necessary drawings or declarations.

20AWG 4-Conductor Cable Specifications

30FT 20AWG 4 conductor electrical chain shielded wire

20AWG 4-Core Technical Data

Rated Voltage: 300V Number of Conductors: 4 Twisted
Rated Temperature: 80°C / 176°F Size: 20AWG
Conductor Resistance: 40.1 Ω/km at 20°C (as published; request verified resistance) Conductor Material: Tinned Stranded Copper
Insulation Resistance: 10MΩ/KM 20°C Insulation Material: PVC (RoHS)
Dielectric Test: 2000AC V/min Isolation Material: Cotton Rope and Cotton Paper
Material: PVC + Tinned Copper Jacket Material: PVC (RoHS)
Conductor Color: Black, White, Yellow and Green, Red
Jacket Dia(mm): 7.4 ± 0.3

The published conductor resistance is 40.1 Ω/km at 20°C. Request a current model-specific technical sheet and test report before using this figure to calculate voltage drop or compare conductor gauges. The stated dielectric and insulation resistance test notation should also be confirmed.

Product illustrations refer to a UL claim and the insulation material listing includes RoHS. Ask for documents that identify this exact cable model, the applicable standards, test scope and issuing organization before relying on those statements.

Request 20AWG 4-Core Technical Information

Shielded Drag Chain Cable Features

Zhong Hua Jiang cable and CNC product information graphic

UL Documentation: Verify by Cable Model 15 Million Flex Cycles — Test Conditions on Request Shielded Tinned Copper Core

Cable Construction Benefits

why choose Zhong Hua Jiang shielded chain wire

oxidation resistance shielded wire low eccentricity electrical wire high conductivity tinned copper wire insulation resistant shielded cable
Oxidation Resistance Low Eccentricity High Conductivity Insulation Resistant

High-Flex Cable for Drag Chains

extreme flexible 20AWG 4 conductor chain shielded cable

The published promotional images mention 15 million flex cycles. Actual durability depends on the tested model, dynamic bend radius, cycle speed, travel distance and installation conditions. Request applicable test records before specifying this figure in a machine design.

For moving cable systems, check the cable manufacturer’s allowed dynamic bending radius, minimum installation clearance, travel speed and strain-relief guidance. Jacket diameter alone does not establish the approved minimum bending radius.

The published jacket diameter is 7.4 ± 0.3mm. Allow for the maximum tolerance when reviewing cable gland size, carrier compartment width, connector entry, packing density and any manufacturer-specified minimum dynamic bending radius.

Tinned Copper Conductor Construction

Advantage of Tinned Copper

tinned copper conductor pure copper conductor copper clad aluminum conductor

Tinned Copper Pure Copper CCA Copper Clad Aluminum
Easy to Solder yes icon no icon no icon
Copper Conductor Performance yes icon yes icon no icon
Anti-oxidation yes icon no icon no icon
Anti-corrosion yes icon no icon no icon
Application-Dependent Durability yes icon no icon no icon

The tinned-copper strands are intended for reliable conductive connections and practical solder termination. Tin plating can improve oxidation resistance at exposed strand surfaces when compared with bare copper.

The service life of a moving cable depends on the complete conductor, shield, filler and jacket construction, as well as its cable-chain installation and operating conditions.

For circuit design and voltage-drop estimates, request verified conductor-resistance data for this exact 20AWG model and calculate the electrical path length according to the actual sensor or controller circuit.

Shielding for Moving Control Circuits

20AWG 4 conductor chain shielded wire structure

A correctly terminated cable shield can help limit coupled electromagnetic interference from nearby motors, drives and switching devices.

Follow approved controller grounding and shield-termination instructions. Keep sensitive low-level control wiring separate from higher-noise VFD power output circuits where the equipment design specifies separation.

The shield is an electromagnetic-interference control measure. Any protective-earth conductor must satisfy the machine wiring design and applicable standards independently of the screen.

A published high-flex claim does not by itself define service life. Match the cable to its tested carrier bend radius, travel distance and speed, temperature, permitted routing and end-fixation details. The source imagery mentions 15 million flex cycles but does not define the test conditions.

Discuss Drag Chain Installation Requirements

CNC Sensor and Automation Cable Applications

application of electrical chain shielded wire for CNC and automation equipment

Four individually insulated conductors can be evaluated for compatible CNC control circuits, multi-signal sensor arrangements and other industrial automation wiring where the approved circuit diagram calls for four electrical paths.

Typical projects may involve sensor and switch wiring, controller interfaces and machinery-mounted signals carried through a drag chain. Verify the conductor pinout, required signal pairs, load current, electrical compatibility and safety requirements before installation.

Four cores do not automatically make the cable suitable for every stepper motor, encoder, communications bus or spindle VFD output. The motor or device manufacturer must confirm wire gauge, pair arrangement where applicable, shielding, insulation and grounding requirements.

For OEM supply, share the four-conductor wiring schedule, required length and packaging, expected order volume, connector or gland design, routing near noisy machinery, moving bend parameters and compliance documents required for this exact model.

Zhong Hua Jiang electrical shielded wire product category

20AWG 4-Core Shielded Cable Selection Guide

Choose the number of insulated conductors from the machine terminal drawing. A shielded four-core cable has four insulated electrical paths; the overall screen is not a fifth conductor or a substitute for protective earth.

20AWG 2-Core vs 3-Core vs 4-Core Shielded Cable

A larger core count supports more separately insulated paths, but the correct version depends on the approved circuit design. Consider conductor identification and whether protective-earth requirements apply independently of signal conductors.

Cable construction Insulated cores Selection consideration
20AWG × 2 Two Suitable only where the diagram requires two separate paths
20AWG × 3 Three Consider where a compatible circuit requires three paths
20AWG × 4 Four Consider where a compatible circuit requires four paths

7.4mm Cable Diameter and Drag Chain Clearance

The outer diameter is specified as 7.4 ± 0.3mm. Use the tolerance range when checking cable clamps, gland selection and drag-chain capacity, and obtain the model-approved dynamic bend radius rather than estimating from outside diameter.

Four Conductor Colors and Yellow/Green Identification

The source lists Black, White, Yellow and Green, Red. Confirm that yellow and green denote one striped yellow/green conductor before ordering and follow protective-earth color rules applicable to the equipment and country of use.

Shield Termination Around CNC Drives and Motors

Follow the controller and drive manufacturer’s guidance on shield bonding, separation from noisy motor leads and protective-earthing. The shield helps reduce coupled noise when installed correctly; it does not automatically establish suitability for an encoder, digital bus or VFD motor-output cable.

Send 20AWG Four-Core Cable Requirements

Related Shielded Wire Categories

Zhong Hua Jiang also lists shielded drag-chain and double-shielded electrical cable categories. Select the family based on the specified core count, conductor gauge, shielding construction, cable motion, system noise level and equipment requirements.

Zhong Hua Jiang Company Profile

Zhong Hua Jiang company profile

CNC Wiring and Shielded Cable Supplier

Zhong Hua Jiang company avatar

How We Started

Huajiang was founded in 2000, beginning with CNC engraving spindle motors and later developing VFDs, CNC machines, accessories and electrical cables. The Zhong Hua Jiang brand was introduced in 2018 for international customers.

Manufacturing Experience

The company has over 20 years of experience in CNC products and cites design patent No. 200730184245.5 for an air-cooled spindle-motor series. For electrical wire purchases, request applicable documents for the specific cable part number.

Why Work with Zhong Hua Jiang

quality assurance patents and brand value
Quality Assurance Superior quality performance Strict quality control Patents and Certifications Several patents for air-cooled spindle motors Additional Brand Value Brand value highly recognized by the market
reasonable price service and delivery
Reasonable Price Direct factory sales High cost performance Full Time Service Professional technical support Quick customer service Fast and Reliable Delivery Fast and efficient delivery Real-time tracking and updates

CNC Manufacturing Experience Since 2000

Related CNC Equipment and Wiring Products

CNC Router Machines

The company supplies CNC router models including 3018, 3020, 3040 and 6090 for compatible engraving and machining work.

CNC Spindle Motors

Its equipment range includes air-cooled and water-cooled CNC spindle motors suited to different machine and cooling configurations.

CNC Accessories

Related CNC accessories include limit switches, Z probes, emergency-stop components and other equipment control accessories.

Electrical Wires

The wire range includes moving-use shielded chain cable and other shielded electrical wiring for compatible CNC machine connections.

Stepper Motors

Stepper motors and related motion components serve compatible positioning and automation systems.

OEM and Wholesale Supply of 20AWG 4-Core Cable

Machine manufacturers, distributors and importers can send required lengths, estimated order quantity, application, destination, installation drawings, cable gland or connector dimensions and any specific test or compliance needs for quotation and technical review.

For engineering qualification, request four-core identification, shielding construction, tested conductor resistance, bend radius and flex-life conditions, plus valid product-specific conformity or listing records where required.

Request Wholesale or OEM Cable Pricing

Product Documents and Certifications

Zhong Hua Jiang cable and CNC product information graphic

Company-level customer feedback and certifications may cover multiple product families. Request product-specific records referencing the 20AWG four-conductor cable purchased.

Customer Feedback

customer feedback for Zhong Hua Jiang electrical shielded wire

Frequently Asked Questions

What is 20 Gauge 4 Conductor Electrical Chain Shielded Wire used for?

This 20AWG four-core shielded cable is presented for compatible CNC machine wiring and automation signal circuits in moving cable carriers where four insulated conductors are specified.

Why choose shielded wire instead of ordinary unshielded wire?

Shielded wiring may reduce electromagnetic interference when screen bonding, cable separation and equipment grounding are executed according to the machine and controller requirements.

Is this 20AWG 4 conductor cable suitable for drag chains?

The product is presented for cable-chain operation. The technical table does not give a numerical minimum dynamic bend radius, test speed, acceleration or travel stroke. Obtain the applicable values before approving repetitive movement.

What are the main specifications of this 20/4 shielded cable?

The published table lists four twisted 20AWG tinned stranded copper conductors, 300V, 80°C and 7.4 ± 0.3mm jacket diameter. Its 40.1 Ω/km at 20°C conductor-resistance figure should be confirmed using a test record for this particular model.

What are the conductor colors for this 20 gauge 4 conductor wire?

The published core colors are Black, White, Yellow and Green, Red. This may describe black, white, yellow/green striped and red conductors. Confirm the exact four-core identification in the cable drawing; yellow/green identification is subject to protective-earth conventions under applicable electrical standards.

Why does this electrical chain wire use tinned stranded copper?

Tinned stranded copper supports electrical conduction, solderability and resistance to surface oxidation; repeated-bending capability also depends on jacket, shielding and movement parameters.

Can Zhong Hua Jiang provide custom shielded wire solutions?

Discuss requested cable lengths, packaging, core color identification or other OEM requirements with the supplier and obtain technical confirmation before changing the ordered specification.

How do I request a quote for 20 Gauge 4 Conductor Shielded Chain Wire?

When requesting a price, provide 20AWG × 4, expected purchasing volume, required lengths, wiring or connection diagram, working voltage and current, cable-carrier dimensions, installation environment, destination and any document requirements.

Who supplies this 20AWG four-core shielded cable?

Huajiang started with CNC spindle motor production in 2000 and expanded into machine tools, VFDs, accessories and electrical cabling. The Zhong Hua Jiang brand was established in 2018 for international markets.

What is 20AWG four-core shielded drag chain cable?

It is a shielded, PVC-insulated and PVC-jacketed electrical cable with four twisted tinned stranded copper conductors for compatible machine control and moving cable-carrier installations.

What is the outside diameter of the 20AWG four-core cable?

The published overall jacket diameter is 7.4 ± 0.3mm. Confirm the drawing for connector entry and cable-carrier space calculations.

What are the rated voltage and operating temperature?

The technical table lists 300V and 80°C (176°F). Operating current and complete installation suitability must be evaluated separately.

What conductor resistance is listed for this cable?

The original product specification lists 40.1 Ω/km at 20°C. Obtain a cable-specific technical sheet or measured report before relying on that number for electrical design.

What are the four conductor colors?

The published wording is Black, White, Yellow and Green, Red. Confirm the final color code and whether yellow/green is a single striped protective-earth conductor on the approved wiring drawing.

Can yellow/green be used as a signal wire?

Do not use yellow/green for a different purpose where applicable electrical standards reserve it for protective earth. Follow the machine electrical design and approved color identification.

How does a four-core cable differ from two-core and three-core cable?

Four-core construction provides four separate insulated paths. Select the conductor count specified by the approved circuit, not by the presence of an overall screen.

Can the overall cable shield be counted as a fifth core?

No. The shield is intended for electromagnetic-interference control, not as an independent insulated core or an automatic replacement for protective earth.

Can this cable operate in a moving CNC drag chain?

The product is marketed for drag-chain applications. Confirm the model-specific bend radius, travel distance, operating speed and installation requirements before approving dynamic use.

What is the minimum dynamic bending radius?

No numerical minimum dynamic bending radius is provided in the published table. Request the model-specific installation guidance.

Is 15 million flex cycles a guaranteed working life?

Promotional graphics refer to 15 million cycles, but the test radius, load, speed and environmental conditions are not specified. Obtain supporting tests before adopting this number as a design requirement.

What benefits do tinned stranded copper conductors provide?

Stranding supports conductor flexibility, and tin plating can improve exposed-surface oxidation resistance and help solder termination. Total flex life depends on the complete cable and installation.

How should the shield be grounded?

Follow the control equipment manufacturer’s approved screen bonding scheme and machine grounding design. Shield termination practices depend on electrical noise and the connected equipment.

Can I use the cable near a VFD or spindle motor?

It can be evaluated for nearby screened control wiring with suitable separation and bonding. Do not assume it is qualified as VFD-to-motor output cable without motor-current, EMC and safety checks.

Is this a suitable cable for a four-wire sensor?

It may be considered where an approved sensor wiring diagram requires four compatible insulated paths. Confirm current rating, sensor voltage, connections and relevant signal performance.

Can it drive a four-wire stepper motor?

Do not assume suitability from four cores alone. Stepper driver output current, cable motion, conductor construction and shielding requirements must be checked against the motor and driver documentation.

Can it be used for RS-485, encoder or other data communication?

The published table does not specify characteristic impedance, pair arrangement or protocol testing. Confirm signal and cable construction requirements before use.

Is this cable rated for oil, water, sunlight or outdoor exposure?

The published specifications identify a PVC jacket but do not provide environmental exposure ratings. Request test data for oil, water, UV or chemicals where relevant.

Does the four-core product have a UL or RoHS document?

The original materials contain these references. Request valid supporting documents naming the exact cable model and applicable standards.

Can lengths, conductor colors or packaging be customized?

Share the required length, core identification, packaging and volume for a technical and commercial feasibility review before placing an order.

What details should importers and OEM buyers send for a quotation?

Provide 20AWG × 4, cable length or reel format, quantity, destination, machine application, wiring diagram, moving-cable installation conditions and any documentation required.

Contact Zhong Hua Jiang for 20/4 Cable Pricing

Previous: 
Next: 

Product Category

Apply Our Best Quotation

Global Recruitment of Authorised Agents!

Join us as an exclusive distributor of CNC Router Machines and CNC Spindle Motors. As a professional manufacturer, we provide high-performance machines, attractive profit margins, technical training, and full marketing support. Build a strong partnership with us and expand your market with confidence.

Products

Quick Links

Contact Us

    zhonghuajiang@huajiang.cn
  +86-13915011877
   No.379-2, Hengyu Road, Henglin town, Wujin District, Changzhou, Jiangsu, China
© COPYRIGHT  2025 CHANGZHOU HUAJIANG ELECTRICAL CO.,LTD ALL RIGHTS RESERVED.